[an error occurred while processing this directive] [an error occurred while processing this directive]

Verifying That the Virtual Chassis Ports Are Operational

Purpose

Use the show virtual-chassis vc-port command to display the status of Virtual Chassis ports (VCPs).

Note: The interfaces for VCPs are not displayed when you issue the show interfaces command.

Action

Display the VCP interfaces:


user@SWA-0> show virtual-chassis vc-portall-members

fpc0: -------------------------------------------------------------------------- Interface Type Status or PIC / Port vcp-0 Dedicated Up vcp-1 Dedicated Up 1/0 Configured Up fpc1: -------------------------------------------------------------------------- Interface Type Status or PIC / Port vcp-0 Dedicated Up vcp-1 Dedicated Up 1/0 Configured Up fpc2: -------------------------------------------------------------------------- Interface Type Status or PIC / Port vcp-0 Dedicated Up vcp-1 Dedicated Up 1/0 Configured Up fpc3: -------------------------------------------------------------------------- Interface Type Status or PIC / Port vcp-0 Dedicated Up vcp-1 Dedicated Up 1/0 Configured Up

Meaning

The dedicated VCPs are displayed as vcp-0 and vcp-1. The uplinks set as VCPs are displayed as 1/0. The FPC slots for EX-series switches are the same as the member IDs.