timeslots
Syntax
Hierarchy Level
- [edit interface e1-fpc/pic/port],
- [edit interface t1-fpc/pic/port],
- [edit interfaces interface-name e1-options],
- [edit interfaces interface-name partition partition-number],
- [edit interfaces interface-name t1-options]
Release Information
Statement introduced before JUNOS Release 7.4.
Description
For E1 and T1interfaces, allocate the specific time slots by number.
![]() |
Note: When configuring E1 interfaces on the 10-port Channelized E1/T1 IQE PIC, timeslots must be set at the [edit interface e1-fpc/pic/port] hierarchy level. When configuring T1 interfaces on the 10-port Channelized E1/T1 IQE PIC, timeslots must be set at the [edit interface t1-fpc/pic/port] hierarchy level. |
Options
-
time-slot-range—Actual time slot numbers allocated:
- Range:
![]() |
Note: When creating fractional E1 interfaces only, if you connect a 4-port E1 PIC interface to a device that uses time slot numbering from 2 through 32, you must subtract 1 from the configured number of time slots. |
Usage Guidelines
See Configuring Channelized E1 IQ and IQE Interfaces, Configuring Channelized T3 IQ Interfaces, Configuring Fractional E1 Time Slots, Configuring Fractional T1 Time Slots, and configuring Configuring a Channelized T1/E1 Interface to Drop and Insert Time Slots.
Required Privilege Level
interface—To view this statement in the configuration.