minimum-links
Syntax
Hierarchy Level
- [edit interfaces aex aggregated-ether-options],
- [edit interfaces asx aggregated-sonet-options],
- [edit interfaces interface-name mlfr-uni-nni-bundle-options],
- [edit interfaces interface-name unit logical-unit-number],
- [edit logical-systems logical-system-name interfaces interface-name unit logical-unit-number]
Release Information
Statement introduced before JUNOS Release 7.4.
Description
For aggregated Ethernet, SONET/SDH, multilink, link services, and voice services interfaces only, set the minimum number of links that must be up for the bundle to be labeled up.
Options
-
number—Number of links.
- Range: 1 through 8 (1 through 16 for Ethernet and SONET interfaces on the MX-series, M320, M120, T-series or TX matrix routers)
- Default: 1
Usage Guidelines
See Configuring Aggregated Ethernet Minimum Links, Configuring Aggregated SONET/SDH Interfaces, or the JUNOS Services Interfaces Configuration Guide.
Required Privilege Level
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.