minimum-links

Syntax

minimum-links number;

Hierarchy Level

[edit interfaces aex aggregated-ether-options],
[edit interfaces asx aggregated-sonet-options],
[edit interfaces interface-name mlfr-uni-nni-bundle-options],
[edit interfaces interface-name unit logical-unit-number],
[edit logical-systems logical-system-name interfaces interface-name unit logical-unit-number]

Release Information

Statement introduced before JUNOS Release 7.4.

Description

For aggregated Ethernet, SONET/SDH, multilink, link services, and voice services interfaces only, set the minimum number of links that must be up for the bundle to be labeled up.

Options

number—Number of links.

Range: 1 through 8 (1 through 16 for Ethernet and SONET interfaces on the MX-series, M320, M120, T-series or TX matrix routers)
Default: 1

Usage Guidelines

See Configuring Aggregated Ethernet Minimum Links, Configuring Aggregated SONET/SDH Interfaces, or the JUNOS Services Interfaces Configuration Guide.

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.


Updated: 2009-04-07