Syntax

lmi {
lmi-type (ansi | itu);
n391dte number;
n392dce seconds;
n392dte number;
n393dce number;
n393dte number;
t391dte number;
t392dce seconds;
}

Hierarchy Level

[edit interfaces interface-name]

Release Information

Statement introduced before JUNOS Release 7.4.

Description

Set Frame Relay keepalive parameters.

Options

n391dte—DTE full status polling interval.

Range: 1 through 255
Default: 6

n392dce—DCE error threshold, in number of errors.

Range: 1 through 10
Default: 3

n392dte—DTE error threshold, in number of errors.

Range: 1 through 10
Default: 3

n393dce—DCE monitored event-count.

Range: 1 through 10
Default: 4

n393dte—DTE monitored event-count.

Range: 1 through 10
Default: 4

t391dte—DTE polling timer.

Range: 5 through 30 seconds
Default: 10 seconds

t392dce—DCE polling timer.

Range: 5 through 30 seconds
Default: 15 seconds

The remaining statements are explained separately.

Usage Guidelines

See Configuring Frame Relay Keepalives.