crc-minor-alarm-threshold
Syntax
Hierarchy Level
Release Information
Statement introduced in JUNOS Release 8.5.
Description
Minor alarm error thresholds for T1 CRC errors. When the threshold is exceeded for one second, a defect condition is declared. If the defect condition continues for the monitoring period, an alarm condition is declared.
Default
10-second monitoring period for values 1e-3, 5e-4, 1e-4, and 5e-5. The 1e-5 value uses a 50-second monitoring period. The 5e-6 value uses a 100-second monitoring period. The 1e-6 value uses a 500-second monitoring period.
Options
-
rate—Error rate expressed as the number of errors per number of bits. The value 1e-3 is one error in 10–3 bits and 5e-4 is five errors in 10–4 bits.
- Default: 5e-6
Usage Guidelines
See Configuring T1 CRC Error Minor Alarm Thresholds.
Required Privilege Level
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.