clocking-mode
Syntax
Hierarchy Level
- [edit interfaces interface-name serial-options]
Release Information
Statement introduced before JUNOS Release 7.4.
Description
For EIA-530 and V.35 interfaces, configure the clock mode. You cannot configure clocking-mode dce on a DTE router using an X.21 serial line protocol (detected automatically when an X.21 cable is plugged into the serial interface).
Options
-
dce—DCE timing (DTE mode only, not valid for X.21).
-
internal—Internal baud timing.
-
loop—Loop timing.
- Default: loop
Usage Guidelines
See Configuring the Serial Clocking Mode.
Required Privilege Level
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration