clocking
Syntax
Hierarchy Level
Release Information
Statement introduced before JUNOS Release 7.4.
interface option added in JUNOS Release 8.2.
Description
For interfaces that can use various clock sources, configure the source of the transmit clock on each interface.
Options
-
external—The clock source is provided by the data communication equipment (DCE).
-
interface interface-name—For interfaces operating on T1/E1 PIMs for J-series Services Routers only, configure clocking for the drop-and insert feature. When configuring this feature, both ports must use the same clock source: either the router’s internal clock or an external clock on one of the interfaces. If an external clock source is required, one interface must specify clocking external and the other must specify the same clock.
-
internal—Use the internal stratum 3 clock as the reference clock.
- Default: internal
Usage Guidelines
See Configuring the Clock Source or Configuring the Clock Source on SONET/SDH Interfaces and , and Configuring a Channelized T1/E1 Interface to Drop and Insert Time Slots.
Required Privilege Level
interface—To view this statement in the configuration.