[an error occurred while processing this directive] [an error occurred while processing this directive]

bert-period

Syntax

bert-period seconds;

Hierarchy Level

[edit interface ce1-fpc/pic/port],
[edit interface ct1-fpc/pic/port],
[edit interfaces interface-name ds0-options],
[edit interfaces interface-name e1-options],
[edit interfaces interface-name e3-options],
[edit interfaces interface-name t1-options],
[edit interfaces interface-name t3-options]

Release Information

Statement introduced before JUNOS Release 7.4.

Description

Configure the duration of a BERT test. Applies to E1, E3, T1, and T3 interfaces, and to E1, E3, T1, and T3 partitions on the channelized interfaces (CE1, CT1, DS3, OC3, OC12, OC48, STM1, STM4, and STM16).

E1 and T1 IQ, IQE, and standard interfaces support an extended BERT period range, up to 86,400 seconds (24 hours).

Note: When configuring CE1 interfaces on the 10-port Channelized E1/T1 IQE PIC, bert-period must be set at the [edit interface ce1-fpc/pic/port] hierarchy level.

When configuring CT1 interfaces on the 10-port Channelized E1/T1 IQE PIC, bert-period must be set at the [edit interface ct1-fpc/pic/port] hierarchy level.

Options

Range:
Default:

Usage Guidelines

See Interface Diagnostics, Configuring E1 BERT Properties, Configuring E3 BERT Properties, Configuring T1 BERT Properties, and Configuring T3 BERT Properties.

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.