bert-algorithm
Syntax
Hierarchy Level
- [edit interface ce1-fpc/pic/port]
- [edit interface ct1-fpc/pic/port]
- [edit interfaces interface-name ds0-options],
- [edit interfaces interface-name e1-options],
- [edit interfaces interface-name e3-options],
- [edit interfaces interface-name t1-options],
- [edit interfaces interface-name t3-options]
Release Information
Statement introduced before JUNOS Release 7.4.
Description
Configure the pattern to send in the bit stream during a bit error rate test (BERT). Applies to T1, E3, T3, and multichannel DS3 interfaces, the channelized interfaces (DS3, OC12, STM1), and channelized IQ and IQE interfaces (E1, E3 and DS3).
![]() |
Note: When configuring CE1 interfaces on the 10-port Channelized E1/T1 IQE PIC, bert-algorithm must be set at the [edit interface ce1-fpc/pic/port] hierarchy level. When configuring CT1 interfaces on the 10-port Channelized E1/T1 IQE PIC, bert-algorithm must be set at the [edit interface ct1-fpc/pic/port] hierarchy level. |
Options
-
algorithm—Pattern to send in the bit stream. There are two categories of test patterns: pseudorandom and repetitive. Both patterns conform to CCITT/ITU O.151, O.152, O.153, and O.161 standards. The algorithm can be one of the following patterns:
- all-ones-repeating—Pattern is all ones.
- all-zeros-repeating—Pattern is all zeros.
- alternating-double-ones-zeros—Pattern is alternating pairs of ones and zeros.
- alternating-ones-zeros—Pattern is alternating ones and zeros.
- pseudo-2e3—Pattern is 23 – 1.
- pseudo-2e4—Pattern is 24 – 1.
- pseudo-2e5—Pattern is 25 – 1.
- pseudo-2e6—Pattern is 26 – 1.
- pseudo-2e7—Pattern is 27 – 1.
- pseudo-2e9-o153—Pattern is 29 – 1, as defined in the O153 standard.
- pseudo-2e10—Pattern is 210 – 1.
- pseudo-2e11-o152—Pattern is 211 – 1, as defined in the O152 standard.
- pseudo-2e15-o151—Pattern is 215 – 1, as defined in the O151 standard.
- pseudo-2e17—Pattern is 217 – 1.
- pseudo-2e18—Pattern is 218 – 1.
- pseudo-2e20-o151—Pattern is 220 – 1, as defined in the O151 standard.
- pseudo-2e20-o153—Pattern is 220 – 1, as defined in the O153 standard.
- pseudo-2e21—Pattern is 221 – 1.
- pseudo-2e22—Pattern is 222 – 1.
- pseudo-2e23-o151—Pattern is 223 – 1, as defined in the O151 standard.
- pseudo-2e25—Pattern is 225 – 1.
- pseudo-2e28—Pattern is 228 – 1.
- pseudo-2e29—Pattern is 229 – 1.
- pseudo-2e31—Pattern is 231 – 1.
- pseudo-2e32—Pattern is 232 – 1.
- repeating-1-in-4—One bit in four is set to 1; the others are set to 0.
- repeating-1-in-8—One bit in eight is set to 1; the others are set to 0.
- repeating-3-in-24—Three bits in twenty four are set to 1; the others are set to 0.
- Default: pseudo-2e3
Usage Guidelines
See Interface Diagnostics, Configuring E3 BERT Properties, Configuring T1 BERT Properties, Configuring T3 BERT Properties, and .
Required Privilege Level
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.