volts -T target
Command supported by JUNOS Release 9.1 and later.
(JCS 1200 platform only) Show voltage information for components in the JCS chassis. This information is useful for viewing current voltage values and voltage threshold settings.
-T target—Specify the target of the volts command. Valid targets for this command are:
operator (display)
Table 30 lists the output fields for the volts command. Output fields are listed in the approximate order in which they appear.
Table 30: volts Output Fields
system> volts -T system:mm[1]
Source Value Warning Reset Hysteresis +5v +4.84 (+4.50,+5.25) (+4.85,+5.15) (+0.35,+0.10) +3.3v +3.26 (+3.00,+3.47) (+3.20,+3.40) (+0.20,+0.07) +12v +12.03 (+10.80,+12.60) (+11.64,+12.36) (+0.84,+0.24) –5v —4.90 (-5.50,–4.75) (-5.15,-4.85) (+0.35,+0.10) +2.5v +2.48 (+2.25,+2.63) (+2.42,+2.58) (+0.17,+0.05) +1.8v +1.76 (+1.62,+1.89) (+1.74,+1.86) (+0.12,+0.03)
system> volts -T system:blade[5]
Source Value Warning 1.8 V Sense +1.79 (+1.61,+1.97) 1.8VSB Sense +1.83 (+1.61,+1.97) 12V Sense +12.33 (+10.79,+13.21) 12VSB Sense +12.30 (+10.74,+13.19) 3.3V Sense +3.31 (+2.96,+3.62) 5V Sense +5.06 (+4.39,+5.48)