temps

Syntax

temps -T target

Release Information

Command supported by JUNOS Release 9.1 and later.

Description

(JCS 1200 platform only) Show temperature information (in degrees Fahrenheit) for components in the JCS chassis. This information is useful for viewing current temperature values and temperature threshold settings.

Options

-T target—Specify the target of the temps command. Valid targets for this command are:

Required Privilege Level

operator (display)

Related Topics

List of Sample Output

temps (Routing Engine)
temps (JCS Management Module)

Output Fields

Table 29 lists the output fields for the temps command. Output fields are listed in the approximate order in which they appear.

Table 29: temps Output Fields

Field Name

Field Description

Value

Current temperature (in degrees Fahrenheit) of the component.

Warning

Temperature at which a warning message occurs.

Reset

Temperature at which the component will reset.

Hysteresis

The amount the temperature must decrease below the Warning threshold before the warning is cleared.

Sample Output

temps (Routing Engine)

system> temps -T system:blade[3]
Component     Value     Warning     Reset     Hysteresis
CPU1          38.00     85.00       95.00     (7.00)
CPU2          35.00     85.00       95.00     (7.00)

temps (JCS Management Module)

system> temps -T system:mm[2]
Component     Value     Warning     Reset     Hysteresis
MM Ambient    43.00     60.00       55.00     (5.00)