    Syntax

    show system errors fru
    <detail>
    <fpc [fpc-slot fpc-slot] [error-id error-id-uri]>

    Release Information

    Command introduced in Junos OS Release 18.2R1.

    Description

    Display information collected by the J-Insight fault monitoring feature. Specifically, display information about detected errors based on the FRU.

    Options

    noneDisplay a brief summary of the system error information for the FRU.
    detail(Optional) Display detailed system error information.
    error-id error-id-uri(Optional) Display system error information for a specific error ID URI.
    fpc-slot fpc-slot(Optional) Display system error information for a specific FPC.

    Required Privilege Level

    admin

    List of Sample Output

    show system errors fru detail
    show system errors fru fpc fpc-slot

    Output Fields

    Table 1 lists the output fields for the show system errors fru command. Output fields are listed in the approximate order in which they appear.

    Table 1: show system errors fru Output Fields

    Field Name

    Field Description

    FRU

    FRU identification number.

    Scope

    An error scope provides a level of classification above error category. Error scope values are: pfe and board.

    Category

    An error category categorizes errors into various subgroups under a specific error scope level. Values include: functional, io, memory, processing, storage, and switch.

    Level

    Severity level of the error.

    Occurred

    Number of times errors of a specific scope, category, and severity level has occurred.

    Cleared

    Number of times errors of a specific scope, category, and severity level were cleared.

    Threshold

    Configured threshold value. The associated detection and recovery actions are triggered when this value is exceeded.

    Action-Taken

    Number of times a user-configured recovery action was triggered for errors of a specific scope, category, and severity level .

    Action

    Action that is triggered when the threshold value is exceeded.

    FPC Slot

    FPC slot number.

    Error Name

    Name of error.

    Identifier

    Each error is uniquely identified with an error ID that is represented as a Uniform Resource Identifier (URI).

    Description

    Description of the error.

    State

    State of the error. Values are: enabled or disabled.

    PFE

    Packet forwarding engine number.

    Configured Level

    Configured severity level of the error.

    Default Level

    Default severity level of the error.

    Count

    The number of times error instances have occurred.

    Threshold

    Number of times the error must occur before a user-configured recovery action is triggered.

    Error Limit

    The maximum number of times the error is reported.

    Clear Count

    Number of times error instances have been cleared.

    Last-occurred (ms ago)

    Amount of time (in milliseconds) passed since the error last occurred.

    Sample Output

    show system errors fru detail

    user@host> show system errors fru detail
    FRU Scope Category Level Occurred Cleared Threshold Action-Taken Action
      1 board functional Minor   0       0      10         0       LOG|
                         Major    0        0       1         0       CM ALARM|DISABLE PFE
                       Fatal      0        0       1         0       RESET
             memory    Minor      0        0      10         0       LOG|
                       Major      0        0       1         0       CM ALARM|DISABLE PFE
                       Fatal      0        0       1         0       RESET
             io        Minor      0        0      10         0       LOG|
                       Major      0        0       1         0       CM ALARM|DISABLE PFE
                       Fatal      0        0       1         0       RESET
             storage   Minor      0        0      10         0       LOG|
                       Major      0        0       1         0       CM ALARM|DISABLE PFE
                       Fatal      0        0       1         0       RESET
             switch    Minor      0        0      10         0       LOG|
                       Major      0        0       1         0       CM ALARM|DISABLE PFE
                       Fatal      0        0       1         0       RESET
           processing  Minor      0       0      10         0       LOG|
                       Major      0        0       1         0       CM ALARM|DISABLE PFE
                       Fatal      0        0       1         0       RESET
     pfe      functional Minor      0       0      10         0       LOG|
                       Major      0        0       1         0       CM ALARM|DISABLE PFE
                       Fatal      0        0       1         0       RESET
             memory    Minor      0        0      10         0       LOG|
                       Major      0        0       1         0       CM ALARM|DISABLE PFE
                       Fatal      0        0       1         0       RESET
             io        Minor      0        0      10         0       LOG|
                       Major      0        0       1         0       CM ALARM|DISABLE PFE
                       Fatal      0        0       1         0       RESET
             storage   Minor      0        0      10         0       LOG|
                       Major      0        0       1         0       CM ALARM|DISABLE PFE
                       Fatal      0        0       1         0       RESET
               switch  Minor      0        0      10         0       LOG|
                       Major      0        0       1         0       CM ALARM|DISABLE PFE
                       Fatal      0        0       1         0       RESET
            Processing Minor      0       0      10         0       LOG|
                       Major      0        0       1         0       CM ALARM|DISABLE PFE
                       Fatal      0        0       1         0       RESET
             Pfe-State: pfe-0 -ENABLED | pfe-1 -DISABLED | pfe-2 – POWER-OFF Pfe-3 – RE-ENABLED
    0
    

    show system errors fru fpc fpc-slot

    user@host> show system errors fru fpc fpc-slot 1 error-id "/fpc/5/pfe/0/cm/0/xfi2xaui/0/XFI2XAUI_CMERROR_FPGA_0_DOWN"
    FPC Slot 1
    --------------------------------------------------
    Error Name            : XFI2XAUI_CMERROR_FPGA_0_DOWN
    Identifier            : /pfe/0/cm/0/xfi2xaui/0/XFI2XAUI_CMERROR_FPGA_0_DOWN
    Description           : XFI2XAUI 0 DOWN
    State                 : enabled
    PFE                   : 0
    Configured Level      : Minor
    Default Level         : Major
    Count                 : 0
    Threshold             : 1
    Error Limit           : 1
    Clear Count           : 0
    Last-occurred(ms ago) : 0
    

    Modified: 2018-06-19