    maximum-inactivity-time

    Syntax

    maximum-inactivity-time {default 10-millisecond-units;maximum 10-millisecond-units;minimum 10-millisecond-units;}

    Hierarchy Level

    Release Information

    Statement introduced in Junos OS Release 9.2.

    maximum and minimum options introduced in Junos OS Release 9.5.

    Description

    Specify default, maximum, and minimum values for the maximum inactivity time. The default value is used if the gateway controller requests that the BGF detect the inactivity timeout event, but the gateway controller does not set a value for the maximum inactivity time. The maximum and minimum values are used to set limits for the maximum inactivity time set by the gateway controller. The BGF issues an error message if the value received from the gateway controller violates the configured minimum or maximum. If the BGF does not receive a message from the gateway controller before the maximum inactivity time expires, it sends a Notify message to the gateway controller. This timer resets each time the BGF receives a message from the gateway controller.

    Options

    default 10–millisecond-units—Default value for the maximum inactivity time.

    Range: 100 through 65,535 (10-millisecond units)

    Default: 12,000

    maximum 10–millisecond-units—Maximum value for the maximum inactivity time.

    Range: 100 through 65,535 (10-millisecond units)

    Default: 12,000

    minimum 10–millisecond-units—Minimum value for the maximum inactivity time.

    Range: 100 through 65,535 (10-millisecond units)

    Default: 12,000