    link-down

    Syntax

    link-down (red | yellow | ignore);

    Hierarchy Level

    [edit chassis alarm ethernet],[edit chassis alarm fibre-channel],[edit chassis interconnect-device name alarm ethernet],[edit chassis node-group name alarm fibre-channel]

    Release Information

    Statement introduced in Junos OS Release 11.3 for the QFX Series.

    Description

    Specify either red, yellow, or ignore to display when the link is down.

    Options

    red

    Indicates that one or more hardware components have failed or exceeded temperature thresholds, or an alarm condition configured on an interface has triggered a critical warning.

    yellow

    Indicates a noncritical condition on the device that, if left unchecked, might cause an interruption in service or degradation in performance. A yellow alarm condition requires monitoring or maintenance.

    ignore

    Suppresses or ignores the alarm.

    Required Privilege Level

    routing—To view this statement in the configuration.
    routing-control—To add this statement to the configuration.