    show class-of-service congestion-notification

    Syntax

    show class-of-service congestion-notification

    Release Information

    Command introduced in Junos OS Release 11.1 for the QFX Series.

    Description

    Display whether priority-based flow control (PFC) is enabled for each IEEE 802.1p code point.

    Options

    none

    Display the PFC state for all IEEE 802.1p code points.

    Required Privilege Level

    view

    Output Fields

    Table 1 describes the output fields for the show class-of-service congestion-notification command. Output fields are listed in the approximate order in which they appear.

    Table 1: show class-of-service congestion-notification Output Fields

    Field Name

    Field Description

    Type

    Type of interfaces on which congestion notification is applied. Congestion notification is applied on input interfaces.

    Index

    Index of this congestion notification profile.

    Name

    Name of the congestion notification profile.

    Cable Length

    Length of the attached physical cable in meters. The default value is 100 meters.

    Priority

    IEEE 802.1p code point.

    PFC

    State of PFC for the corresponding code point, either enabled or disabled.

    MRU

    Maximum receive unit of the interface in bytes. (Incoming traffic that exceeds the MRU size of an interface is dropped.) The default values are:

    • 2500 bytes for priority 3 traffic
    • 9216 bytes for priority 4 traffic

    Note: If you configure flow control on a priority that is not one of the default flow control priorities, the default MRU value is 2500 bytes. For example, if you configure flow control on priority 5 and you do not configure an MRU value, the default MRU value is 2500 bytes.

    Flow-Control-Queues

    Output queue mapping to IEEE 802.1p code points (priorities). Explicit output queue to priority mapping overwrites the default configuration, and only explicitly mapped queues are displayed in the output. Flow control is only enabled on a queue when you enable PFC on the corresponding priority in the input stanza of the congestion notification profile.

    Sample Output

    show class-of-service congestion-notification

    user@switch> show class-of-service congestion-notification
    Name: fcoe_p3_cnp, Index: 12037
    Type: Input
    Cable Length: 100 m
      Priority     PFC          MRU
      000          Disabled 
      001          Disabled 
      010          Disabled 
      011          Enabled      2500 
      100          Enabled      9216 
      101          Disabled 
      110          Disabled 
      111          Disabled 
    Type: Output
      Priority     Flow-Control-Queues 
      000 
                   0
      001 
                   1
      010 
                   2
      011 
                   3
      100                                   
                   4
      101 
                   5
      110 
                   6
      111 
                   7
    
    Name: fcoe_p3_p5_cnp, Index: 46484
    Type: Input
    Cable Length: 100 m
      Priority     PFC          MRU
      000          Disabled 
      001          Disabled 
      010          Disabled 
      011          Enabled      2240 
      100          Disabled 
      101          Enabled      2240 
      110          Disabled 
      111          Disabled 
    Type: Output
      Priority     Flow-Control-Queues 
      011 
                   3
      101 
                   5
    

    Published: 2013-08-15