    show analyzer

    Syntax

    show analyzer analyzer-name

    Release Information

    Command introduced in Junos OS Release 9.0 for EX Series switches.

    Description

    Display information about analyzers configured for port mirroring.

    Options

    analyzer-name

    (Optional) Displays the status of a specific analyzer on the switch.

    Required Privilege Level

    view

     
     

    List of Sample Output

    show analyzer

    Output Fields

    Table 1 lists the output fields for the command-name command. Output fields are listed in the approximate order in which they appear.

    Table 1: show analyzer Output Fields

    Field Name

    Field Description

    Analyzer name

    Displays the name of the analyzer.

    Output interface

    Specifies a local interface to which mirrored packets are sent. An analyzer can have output to either an interface or a VLAN, not both.

    Output VLAN

    Specifies a VLAN to which mirrored packets are sent. An analyzer can have output to either an interface or a VLAN, not both.

    Mirror ratio

    Displays the ratio of packets to be mirrored, between 1 and 2047 where 1 sends copies of all packets and 2047 sends copies of 1 out of every 2047 packets.

    Loss priority

    Displays the loss priority of mirrored packets. By default, loss priority is set to low, with mirrored traffic dropped in preference for regular traffic when capacity is exceeded. For analyzers with output to a VLAN, set the loss priority to high.

    Egress monitored interfaces

    Displays interfaces for which traffic exiting the interfaces is mirrored.

    Ingress monitored interfaces

    Displays interfaces for which traffic entering the interfaces is mirrored.

    Ingress monitored VLANs

    Displays VLANs for which traffic entering the VLAN is mirrored.

    Sample Output

    show analyzer

    user@host> show analyzer
    Analyzer name                  : employee-monitor
      Output interface             : ge-0/0/10.0
      Output VLAN                  : remote-analyzer
      Mirror ratio                 : 1
      Loss priority                : High 
      Egress monitored interfaces  : ge-0/0/3.0
      Ingress monitored interfaces : ge-0/0/0.0
      Ingress monitored interfaces : ge-0/0/1.0
    
    

    Published: 2012-12-07