    Example: Configuring Aggregated Ethernet High-Speed Uplinks Between an EX4200 Virtual Chassis Access Switch and an EX4200 Virtual Chassis Distribution Switch

    EX Series switches allow you to combine multiple Ethernet links into one logical interface for higher bandwidth and redundancy. The ports that are combined in this manner are referred to as a link aggregation group (LAG) or bundle. The number of Ethernet links you can combine into a LAG depends on your EX Series switch model. See Understanding Aggregated Ethernet Interfaces and LACP for more information.

    This example describes how to configure uplink LAGs to connect a Virtual Chassis access switch to a Virtual Chassis distribution switch:

    Requirements

    This example uses the following software and hardware components:

    • Junos OS Release 9.0 or later for EX Series switches
    • Two EX4200-48P switches
    • Two EX4200-24F switches
    • Four XFP uplink modules

    Before you configure the LAGs, be sure you have:

    Overview and Topology

    For maximum speed and resiliency, you can combine uplinks between an access switch and a distribution switch into LAGs. Using LAGs can be particularly effective when connecting a multimember Virtual Chassis access switch to a multimember Virtual Chassis distribution switch.

    The Virtual Chassis access switch in this example is composed of two member switches. Each member switch has an uplink module with two 10-Gigabit Ethernet ports. These ports are configured as trunk ports, connecting the access switch with the distribution switch.

    Configuring the uplinks as LAGs has the following advantages:

    • Link Aggregation Control Protocol (LACP) can optionally be configured for link negotiation.
    • It doubles the speed of each uplink from 10 Gbps to 20 Gbps.
    • If one physical port is lost for any reason (a cable is unplugged or a switch port fails, or one member switch is unavailable), the logical port transparently continues to function over the remaining physical port.

    The topology used in this example consists of one Virtual Chassis access switch and one Virtual Chassis distribution switch. The access switch is composed of two EX4200-48P switches (SWA-0 and SWA-1), interconnected to each other with their Virtual Chassis ports (VCPs) as member switches of Host-A. The distribution switch is composed of two EX4200-24F switches (SWD-0 and SWD-1), interconnected with their VCPs as member switches of Host-D.

    Each member of the access switch has an uplink module installed. Each uplink module has two ports. The uplinks are configured to act as trunk ports, connecting the access switch with the distribution switch. One uplink port from SWA-0 and one uplink port from SWA-1 are combined as LAG ae0 to SWD-0. This link is used for one VLAN. The remaining uplink ports from SWA-0 and from SWA-1 are combined as a second LAG connection (ae1) to SWD-1. LAG ae1 is used for another VLAN.

    Note: If the remote end of the LAG link is a security device, LACP might not be supported because security devices require a deterministic configuration. In this case, do not configure LACP. All links in the LAG are permanently operational unless the switch detects a link failure within the Ethernet physical layer or data link layers.

    Figure 1: Topology for LAGs Connecting an EX4200 Virtual Chassis Access Switch to an EX4200 Virtual Chassis Distribution Switch

    Topology for LAGs Connecting an EX4200 Virtual Chassis
Access Switch to an EX4200 Virtual Chassis Distribution Switch

    Table 1 details the topology used in this configuration example.

    Table 1: Components of the Topology for Connecting a Virtual Chassis Access Switch to a Virtual Chassis Distribution Switch

    SwitchHostname and VCIDBase HardwareUplink ModuleMember IDTrunk Port

    SWA-0

    Host-A Access switch

    VCID 1

    EX4200-48P switch

    One XFP uplink module

    0

    xe-0/1/0 to SWD-0

    xe-0/1/1 to SWD-1

    SWA-1

    Host-A Access switch

    VCID 1

    EX4200-48P switch

    One XFP uplink module

    1

    xe-1/1/0 to SWD-0

    xe-1/1/1 to SWD-1

    SWD-0

    Host-D Distribution switch

    VCID 4

    EX4200 L-24F switch

    One XFP uplink module

    0

    xe-0/1/0 to SWA-0

    xe-0/1/1 to SWA-1

    SWD-1

    Host-D Distribution switch

    VCID 4

    EX4200 L-24F switch

    One XFP uplink module

    1

    xe-1/1/0 to SWA-0

    xe-1/1/1 to SWA-1

    Configuration

    To configure two uplink LAGs from the Virtual Chassis access switch to the Virtual Chassis distribution switch:

    CLI Quick Configuration

    To quickly configure aggregated Ethernet high-speed uplinks between a Virtual Chassis access switch and a Virtual Chassis distribution switch, copy the following commands and paste them into the switch terminal window:

    [edit]
    set chassis aggregated-devices ethernet device-count 2
    set interfaces ae0 aggregated-ether-options minimum-links 1
    set interfaces ae0 aggregated-ether-options link-speed 10g
    set interfaces ae1 aggregated-ether-options minimum-links 1
    set interfaces ae1 aggregated-ether-options link-speed 10g
    set interfaces ae0 unit 0 family inet address 192.0.2.0/25
    set interfaces ae1 unit 0 family inet address 192.0.2.128/25
    set interfaces xe-0/1/0 ether-options 802.3ad ae0
    set interfaces xe-1/1/0 ether-options 802.3ad ae0
    set interfaces xe-0/1/1 ether-options 802.3ad ae1
    set interfaces xe-1/1/1 ether-options 802.3ad ae1

    Step-by-Step Procedure

    To configure aggregated Ethernet high-speed uplinks between a Virtual Chassis access switch and a Virtual Chassis distribution switch:

    1. Specify the number of LAGs to be created on the chassis:
      [edit chassis]
      user@Host-A# set aggregated-devices ethernet device-count 2
    2. Specify the number of links that need to be present for the ae0 LAG interface to be up:
      [edit interfaces]
      user@Host-A# set ae0 aggregated-ether-options minimum-links 1
    3. Specify the number of links that need to be present for the ae1 LAG interface to be up:
      [edit interfaces]
      user@Host-A# set ae1 aggregated-ether-options minimum-links 1
    4. Specify the media speed of the ae0 link:
      [edit interfaces]
      user@Host-A# set ae0 aggregated-ether-options link-speed 10g
    5. Specify the media speed of the ae1 link:
      [edit interfaces]
      user@Host-A# set ae1 aggregated-ether-options link-speed 10g
    6. Specify the interface ID of the uplinks to be included in LAG ae0:
      [edit interfaces]
      user@Host-A# set xe-0/1/0 ether-options 802.3ad ae0
      user@Host-A# set xe-1/1/0 ether-options 802.3ad ae0
    7. Specify the interface ID of the uplinks to be included in LAG ae1:
      [edit interfaces]
      user@Host-A# set xe-0/1/1 ether-options 802.3ad ae1
      user@Host-A# set xe-1/1/1 ether-options 802.3ad ae1
    8. Specify that LAG ae0 belongs to the subnet for the employee broadcast domain:
      [edit interfaces]
      user@Host-A# set ae0 unit 0 family inet address 192.0.2.0/25
    9. Specify that LAG ae1 belongs to the subnet for the guest broadcast domain:
      [edit interfaces]
      user@Host-A# set ae1 unit 0 family inet address 192.0.2.128/25

    Results

    Display the results of the configuration:

    [edit]chassis {aggregated-devices {ethernet {device-count 2;}}}interfaces {ae0 {aggregated-ether-options {link-speed 10g;minimum-links 1;}unit 0 {family inet {address 192.0.2.0/25;}}}ae1 {aggregated-ether-options {link-speed 10g;minimum-links 1;}unit 0 {family inet {address 192.0.2.128/25;}}xe–0/1/0 {ether-options {802.3ad ae0;}}xe–1/1/0 {ether-options {802.3ad ae0;}}xe–0/1/1 {ether-options {802.3ad ae1;}}xe–1/1/1 {ether-options {802.3ad ae1;}}}

    Verification

    To verify that switching is operational and two LAGs have been created, perform these tasks:

    Verifying That LAG ae0 Has Been Created

    Purpose

    Verify that LAG ae0 has been created on the switch.

    Action

    show interfaces ae0 terse

    Interface             Admin      Link Proto      Local             Remote 
    ae0                   up         up
    ae0.0                 up         up     inet     192.0.2.0/25
    

    Meaning

    The output confirms that the ae0 link is up and shows the family and IP address assigned to this link.

    Verifying That LAG ae1 Has Been Created

    Purpose

    Verify that LAG ae1 has been created on the switch

    Action

    show interfaces ae1 terse

    Interface               Admin Link Proto     Local                Remote
    ae1                     up    down
    ae1.0                   up    down inet		  192.0.2.128/25
    

    Meaning

    The output shows that the ae1 link is down.

    Troubleshooting

    Troubleshooting a LAG That Is Down

    Problem

    The show interfaces terse command shows that the LAG is down.

    Solution

    Check the following:

    • Verify that there is no configuration mismatch.
    • Verify that all member ports are up.
    • Verify that a LAG is part of family ethernet switching (Layer 2 LAG) or family inet (Layer 3 LAG).
    • Verify that the LAG member is connected to the correct LAG at the other end.
    • Verify that the LAG members belong to the same switch (or the same Virtual Chassis).

    Published: 2012-12-07