    Verifying That Uplink Failure Detection Is Working Correctly

    Purpose

    Verify that the switch disables the downlink interface when it detects an uplink failure.

    Action

    1. View the current uplink-failure-detection status:
      user@switch> show uplink-failure-detection
      Group                     : group1
      Uplink                    :  ge-0/0/0*
      Downlink                  :  ge-0/0/1*
      Failure Action            :  Inactive
      

      Note: The asterisk (*) indicates that the link is up.

    2. Disable the uplink interface:
      [edit]
      user@switch# set interface ge-0/0/0 disable
    3. Save the configuration on the switch.
    4. View the current uplink-failure-detection status:
      user@switch> show uplink-failure-detection
      Group                     : group1
      Uplink                    :  ge-0/0/0
      Downlink                  :  ge-0/0/1
      Failure Action            :  Active
      

    Meaning

    The output in Step 1 shows that the uplink interface is up, and hence that the downlink interface is also up, and that the status of Failure Action is Inactive.

    The output in Step 4 shows that both the uplink and downlink interfaces are down and that the status of Failure Action is changed to Active. This output shows that uplink failure detection is working.