Help us improve your experience.

Let us know what you think.

Do you have time for a two-minute survey?

Navigation
Guide That Contains This Content
[+] Expand All
[-] Collapse All

    Configuring an Iterator Profile on a Switch (CLI Procedure)

    Ethernet frame delay measurement provides fine control to operators for triggering delay measurement on a given service and can be used to monitor service-level agreements (SLAs). You can create an iterator profile with its parameters to periodically transmit SLA measurement packets in the form of ITU-Y.1731-compliant frames for two-way delay measurement.

    To create an iterator profile:

    1. Specify a name for an SLA iterator profile—for example, i1:
      [edit protocols oam ethernet connectivity-fault-management performance-monitoring]user@switch# edit sla-iterator-profiles i1
    2. (Optional) Configure the cycle time, which is the time (in milliseconds) between back-to-back transmissions of SLA frames.
      [edit protocols oam ethernet connectivity-fault-management performance-monitoring sla-iterator-profiles i1]user@switch# set cycle-time cycle-time-value
    3. (Optional) Configure the iteration period, which indicates the maximum number of cycles per iteration (the number of connections registered to an iterator cannot exceed this value).
      [edit protocols oam ethernet connectivity-fault-management performance-monitoring sla-iterator-profiles i1]user@switch# set iteration-period iteration-period-value
    4. Configure the measurement type as two-way delay measurement.
      [edit protocols oam ethernet connectivity-fault-management performance-monitoring sla-iterator-profiles i1]user@switch# set measurement-type two-way-delay
    5. (Optional) Configure the calculation weight for delay.
      [edit protocols oam ethernet connectivity-fault-management performance-monitoring sla-iterator-profiles i1]user@switch# set calculation-weight delay delay-value
    6. (Optional) Configure the calculation weight for delay variation.
      [edit protocols oam ethernet connectivity-fault-management performance-monitoring sla-iterator-profiles i1]user@switch# set calculation-weight delay-variation delay-variation-value
    7. Configure a remote MEP with the iterator profile.
      [edit protocols oam ethernet connectivity-fault-management maintenance-domain md-name maintenance-association ma-name mep mep-id remote-mep remote-mep-id]user@switch# set sla-iterator-profiles i1

    Published: 2012-12-07