    frame-error

    Syntax

    frame-error count;

    Hierarchy Level

    Release Information

    Statement introduced in Junos OS Release 9.4 for EX Series switches.

    Description

    Configure the threshold value for sending frame error events or taking the action specified in the action profile.

    Frame errors occur on the underlying physical layer. The threshold is reached when the number of frame errors reaches the configured value.

    Options

    count—Threshold count in seconds for frame error events.

    Range: 1 through 100 seconds

    Default: 1 second

    Required Privilege Level

    routing—To view this statement in the configuration.
    routing-control—To add this statement to the configuration.

    Published: 2012-12-07