    Syntax

    clock-step (one-step | two-step);

    Hierarchy Level

    [edit protocols ptp master]

    Release Information

    Statement introduced in Junos OS Release 12.2.

    Description

    Configure the clock step that determines whether the timing information is sent along with the synchronous message (one-step) only or a subsequent follow-up message (two-step) is received for the sent synchronous message.

    Options

    one-step—One clock step to send timing information along with the synchronous message.

    two-step—Two clock steps to send timing information and receive a subsequent follow-up message.

    Default: one-step

    Required Privilege Level

    routing—To view this statement in the configuration.

    routing-control—To add this statement to the configuration.