    Syntax

    cable-length cable-length-value;

    Hierarchy Level

    Release Information

    Statement introduced in Junos OS Release 12.3 for the QFX Series.

    Description

    Specify the length of the cable between the interface and its peer interface in meters. The system uses the cable length and the maximum receive unit (MRU) to calculate the amount of buffer headroom reserved to support priority-based flow control (PFC). The the shorter the cable length and lower the MRU, the less headroom buffer space is required for PFC.

    Note: You can also set a maximum transmission unit (MTU) value (the largest packet size the interface sends) for interfaces by including the mtu statement at the [edit interfaces interface-name] hierarchy level.

    Default

    The default cable length value is 100 meters (approximately 328 feet).

    Options

    cable-length-value—Length of the cable in meters. (Generally from 1 to 300 meters, but there is no configuration restriction.)

    Required Privilege Level

    interfaces—To view this statement in the configuration.