    action-fpc-restart-disable

    Syntax

    action-fpc-restart-disable;

    Hierarchy Level

    [edit chassis fabric degraded]

    Release Information

    Statement added in Junos OS Release 11.4.

    Statement introduced in Junos OS Release 12.1X48R4 for PTX Series Packet Transport Switches.

    Description

    Allow the user to disable restarting of the FPCs during healing from a degraded fabric condition. The device can automatically recover from degraded fabric conditions by restarting both the fabric planes and the FPCs. If the action-fpc-restart-disable statement is configured, the healing attempt is limited to restarting the fabric planes only.

    Default

    The system will detect a blackholing condition and try to heal the system.

    Required Privilege Level

    interface—To view this statement in the configuration.

    interface-control—To add this statement to the configuration.