Help us improve your experience.

Let us know what you think.

Do you have time for a two-minute survey?

Navigation
Guide That Contains This Content
[+] Expand All
[-] Collapse All

    show redundant-power-system status

    Syntax

    show redundant-power-system status

    Release Information

    Command introduced in Junos OS Release 12.1 for EX Series switches.

    Description

    Display the status information for the switch connectors on the Redundant Power System (RPS).

    Required Privilege Level

    view

    List of Sample Output

    show redundant-power-system status (Standalone Switch)
    show redundant-power-system status (EX3300 Virtual Chassis)

    Output Fields

    Table 1 lists the output fields for the show redundant-power-system status command. Output fields are listed in the approximate order in which they appear.

    Table 1: show redundant-power-system status Output Fields

    Field Name

    Field Description

    Level of Output

    RPS

    Serial number of the RPS.

    All levels

    Port

    Number of the switch connector.

    All levels

    Status

    Status of the switch connector:

    • ARMED—The switch is ready to get backup power from RPS if power supply fails on the switch.
    • OFF—The switch has zero and is not configured to receive backup power from RPS.
    • BACKED-UP—The switch is receiving power backup from RPS.
    • OVER-SUBSCRIBED—The switch cannot receive backup power from RPS even if you set the .

    All levels

    Priority

    Priority value of the switch connector.

    All levels

    Power-Requested

    Power requested by the switch on the corresponding switch connector.

    All levels

    Sample Output

    show redundant-power-system status (Standalone Switch)

    user@switch> show redundant-power-system status
    Gathering requested information.
    RPS-CG0209121807
    Port Status        Power-requested
      0  Armed        3         930W          
      1  Off          1         ---              
      2  Off          1         ---              
      3  Off          1         ---              
      4  Off          1         ---              
      5  Off          1         ---              
    

    show redundant-power-system status (EX3300 Virtual Chassis)

    user@switch> show redundant-power-system status
    Gathering requested information.
    RPS-CG0209121814
    Port Status        Power-requested
      0  OFF          1         ---          
      1  OFF          1         ---          
      2  OFF          1         ---          
      3  OFF          1         ---          
      4  OFF          1         ---          
      5  Armed        5         930W         
    RPS-CG0209121815
    Port Status        Power-requested
      0  OFF          1         ---          
      1  OFF          1         ---          
      2  OFF          1         ---          
      3  OFF          1         ---          
      4  Armed        4         930W         
      5  OFF          1         ---          
    

    Published: 2012-12-07