Help us improve your experience.

Let us know what you think.

Do you have time for a two-minute survey?

Navigation
Guide That Contains This Content
[+] Expand All
[-] Collapse All
     

    Related Documentation

     

    show redundant-power-system led

    Syntax

    show redundant-power-system led

    Release Information

    Command introduced in Junos OS Release 12.1 for EX Series switches.

    Description

    Display information about fan status, Redundant Power System (RPS) status, and the switch connectors as displayed by the corresponding LEDs on the RPS.

    Required Privilege Level

    view

     

    Related Documentation

     

    List of Sample Output

    show redundant-power-system led (Standalone Switch)
    show redundant-power-system led (EX3300 Virtual Chassis)

    Output Fields

    Table 1 lists the output fields for the show redundant-power-system led command. Output fields are listed in the approximate order in which they appear.

    Table 1: show redundant-power-system led Output Fields

    Field Name

    Field Description

    Level of Output

    RPS

    The serial number of the RPS.

     

    RPS Fan

    Status of the RPS power supply fans as displayed by the LED:

    • Green—All RPS power supply fans are operating fine.
    • Amber—A fan has failed in at least one RPS power supply.

    All levels

    RPS System Status

    Status of the RPS system as displayed by the LED:

    • Green—The RPS is active.
    • Blinking green—The RPS is booting.
    • Amber—An RPS power supply has failed.
    • Off—The RPS is off.

    All levels

    RPS Port LED Status

    Status of the RPS switch connectors as displayed by the LEDs. These LEDs indicate whether the redundant power source is being used.

    • Green—The RPS connector is enabled and connected to a switch but the RPS is not actively backing up the switch.
    • Blinking green—The RPS is backing up the switch connected to the port.
    • Off—The RPS connector is not connected to a switch.
    • Amber—The RPS is oversubscribed and the backup power to the switch has failed.

    All levels

    Port

    Number of one of the six switch connectors on the RPS.

    All levels

    Status

    Status of each switch connector on the RPS.

    All levels

    Sample Output

    show redundant-power-system led (Standalone Switch)

    user@switch> show redundant-power-system led
    Gathering requested information.
    RPS-CG0209121807
        RPS Fan: GREEN
        RPS System Status: GREEN
    RPS Port LED Status
    Port  Status
       0  GREEN 
       1  OFF   
       2  OFF   
       3  OFF   
       4  OFF   
       5  OFF   
    

    show redundant-power-system led (EX3300 Virtual Chassis)

    user@switch> show redundant-power-system led
    Gathering requested information.
    RPS-CG0209121814
        RPS Fan: GREEN
        RPS System Status: GREEN
    RPS Port LED Status
    Port  Status
       0  OFF 
       1  OFF   
       2  OFF   
       3  OFF   
       4  OFF   
       5  GREEN
    RPS-CG0209121815
        RPS Fan: GREEN
        RPS System Status: GREEN
    RPS Port LED Status
    Port  Status
       0  OFF 
       1  OFF   
       2  OFF   
       3  OFF   
       4  GREEN   
       5  OFF   
    

    Published: 2012-12-07