Help us improve your experience.

Let us know what you think.

Do you have time for a two-minute survey?

Navigation
Guide That Contains This Content
[+] Expand All
[-] Collapse All

    show chassis synchronization

    Syntax

    show chassis synchronization<extensive><backup | master>

    Release Information

    Command introduced in Junos OS Release 7.6 for M320 routers.

    Command introduced in Junos OS Release 8.3 for M40e routers.

    Command introduced in Junos OS Release 9.3 for M120 routers.

    Command introduced in Junos OS Release 10.2 for T320, T640, and T1600 routers.

    Command introduced in Junos OS Release 12.1 for PTX Series Packet Transport Switches.

    Command introduced in Junos OS Release 12.2 for ACX Series routers.

    Description

    (ACX Series, M320, M40e,M120, T320, T640, and T1600 routers and PTX Series Packet Transport Switches only) Display information about the external clock source currently used for chassis synchronization.

    Options

    extensive

    (Optional) Display clock synchronization information in detail.

    backup

    (Optional) Display clock synchronization information about the backup clock.

    master

    (Optional) Display clock synchronization information about the master clock.

    Required Privilege Level

    maintenance

    List of Sample Output

    show chassis synchronization
    show chassis synchronization master
    show chassis synchronization backup
    show chassis synchronization extensive
    show chassis synchronization (T320, T640, and T1600 Routers)
    show chassis synchronization (PTX Series Packet Transport Switches)
    show chassis synchronization extensive (ACX Series Routers)

    Output Fields

    Table 1 lists the output fields for the show chassis synchronization command. Output fields are listed in the approximate order in which they appear.show chassis synchronizationshow chassis synchronizationshow chassis synchronization

    Table 1: show chassis synchronization Output Fields

    Field Name

    Field Description

    Current state

    Indicates current status of external clock sources:

    • backup—Source is currently the backup clock source.
    • master—Source is currently the master clock source.
    • Online-Master—(PTX Series Packet Transport Switches) Source is the master clock. Source is online.
    • Online-Standby—(PTX Series Packet Transport Switches) Source is the standby (backup) clock. Source is online.

    Current clock state

    Indicates current source of external synchronization:

    • internal—Source is providing its own clocking.
    • locked to master CB—(M320, M40e, and M120 routers) Source is locked to master clock source.
    • locked to master SCG—(T320, T640, and T1600 routers) Source is locked to master clock source.
    • locked to master CCG—(PTX Series Packet Transport Switches) Source is locked to master clock source.

    Selected for

    Number of seconds this clock has been the master or backup clock source.

    Selected since

    Timestamp for establishment as master or backup clock source.

    Deviation (in ppm)

    Difference in clock timing, in parts per million (ppm).

    Last deviation (in ppm)

    Previous difference in clock timing, if any, in ppm.

    Configured sources

    Information about clock sources eligible for selection as master clock.

    Source

    Information about external clock sources.

    Priority

    Indicates priority of external clock sources:

    • primary—Source is a primary reference.
    • secondary—Source is a secondary reference.

    Deviation (in ppm)

    Current difference in clock timing, in ppm:

    • measuring—Establishing source deviation.
    • number—Deviation in ppm.

    Last deviation (in ppm)

    Previous difference in clock timing, in ppm:

    • number—Deviation in ppm.

    Status

    Indicates status of external sources:

    • present—Source is configured and present.
    • qualified—Source is eligible for synchronization source.

    Sample Output

    show chassis synchronization

    user@host> show chassis synchronization
    Clock Synchronization Status :
      Clock module on CB 0
        Current state            : master
        Current clock state      : internal
          Selected for           : 18 hours, 12 minutes, 43 seconds
          Selected since         : 2008-09-10 03:27:47 PDT
          Deviation (in ppm)     : +0.00
          Last deviation (in ppm): +0.00
    Clock Synchronization Status :
      Clock module on CB 1
        Current state            : backup
        Current clock state      : locked to master CB
          Selected for           : 1 day, 12 hours, 49 minutes, 20 seconds
          Selected since         : 2008-09-09 08:51:10 PDT

    show chassis synchronization master

    user@host> show chassis synchronization master
    Clock Synchronization Status :
      Clock module on CB 0
        Current state            : master
        Current clock state      : internal
          Selected for           : 8 days, 21 minutes, 12 seconds
          Selected since         : 2008-08-27 21:05:40 PDT
          Deviation (in ppm)     : +0.00
          Last deviation (in ppm): +0.00

    show chassis synchronization backup

    user@host> show chassis synchronization backup
    Clock Synchronization Status :
      Clock module on CB 1
        Current state            : backup
        Current clock state      : locked to master CB
          Selected for           : 34 days, 20 hours, 17 minutes, 8 seconds
          Selected since         : 2008-08-01 01:22:16 PDT

    show chassis synchronization extensive

    user@host> show chassis synchronization extensive
    Clock Synchronization Status :
      Clock module on CB 0
        Current state            : master
        Current clock state      : internal
          Selected for           : 8 days, 36 minutes, 29 seconds
          Selected since         : 2008-08-27 21:05:40 PDT
          Deviation (in ppm)     : +0.00
          Last deviation (in ppm): +0.00
    Clock Synchronization Status :
      Clock module on CB 1
        Current state            : backup
        Current clock state      : locked to master CB
          Selected for           : 34 days, 20 hours, 19 minutes, 53 seconds
          Selected since         : 2008-08-01 01:22:16 PDT

    show chassis synchronization (T320, T640, and T1600 Routers)

    user@host> show chassis synchronization
        Clock Synchronization Status :
          Clock module on SCG 0
            Current state            : master
            Current clock state      : locked to external-a
              Selected for           : 2 hours, 28 minutes, 4 seconds
              Selected since         : 2006-02-17 01:12:58 PST
            Configured sources
              Source      Priority   Deviation    Last deviation   Status
                                     (in ppm)     (in ppm)
              external-a  primary    measuring    -0.10            in-use
              external-b  secondary  -0.10        -0.10            qualified
        Clock Synchronization Status :
          Clock module on SCG 1
            Current state            : backup
            Current clock state      : locked to master SCG
              Selected for           : 19 hours, 49 minutes, 14 seconds
              Selected since         : 2006-02-16 07:51:48 PST
            Configured sources
              Source      Priority   Deviation    Last deviation   Status
                                     (in ppm)     (in ppm)
              external-a  primary    -0.25        -0.25            qualified
              external-b  secondary  -0.25        -0.25            qualified
    

    show chassis synchronization (PTX Series Packet Transport Switches)

    user@host> show chassis synchronization
    Clock Synchronization Status :
      Clock module on CCG 0
        Current state            : Online - Master
        Current clock state      : internal
          Selected for           : 1 hour, 24 minutes, 21 seconds
          Selected since         : 2011-03-21 15:59:37 PDT
          Deviation (in ppm)     : +0.51
          Last deviation (in ppm): +0.51
    Clock Synchronization Status :
      Clock module on CCG 1
        Current state            : Online - Standby
        Current clock state      : locked to master CCG
          Selected for           : 1 hour, 39 minutes, 12 seconds
          Selected since         : 2011-03-21 15:44:46 PDT
    

    show chassis synchronization extensive (ACX Series Routers)

    user@host> show chassis synchronization extensive
    Current clock status  : Locked
    Clock locked to       : Primary
    Configured sources:
    Interface           : ce1-0/0/4
    Status              : Primary                      Index       : 132
    Clock source state  : Clk qualified   Priority    : Default(8)
    Configured QL       : PRC                   ESMC QL     : Unknown
    Clock source type   : ifd                    Clock Event : Clock locked
    Kernel flags        : Up,pri,
    

    Published: 2013-01-30