    show chassis fabric degraded-fabric-reachability

    Syntax

    show chassis fabric degraded-fabric-reachability

    Release Information

    Command introduced in Junos OS Release 12.1X48R4 for PTX Series Packet Transport Switches.

    Description

    Display the current state of reachability between the Packet Forwarding Engines in the system.

    Additional Information

    Required Privilege Level

    view

    List of Sample Output

    show chassis fabric degraded-fabric-reachability

    Output Fields

    Table 1 lists the output fields for the show chassis fabric degraded-fabric-reachability command. Output fields are listed in the approximate order in which they appear.

    Table 1: show chassis fabric degraded-fabric-reachability Output Fields

    Field Name

    Field Description

    FPC

    Display fabric reachability for the displayed FPC slot.

    PFE

    Display fabric reachability for the displayed PFE slot on a per SIB and plane basis.

    SIBx_Plane y

    Display the SIB (x) and plane (y) where link errors occurred.

    Link errors FPC/PFEs

    Display the list of FPC and PFE slots that are unreachable for the displayed SIB and plane due to link errors.

    Sample Output

    show chassis fabric degraded-fabric-reachability

    user@host> show chassis fabric degraded-fabric-reachability
    Degraded Fabric reachability Information:
    FPC #0
        PFE #0
          SIB0_Plane 0
               Link errors  FPC/PFEs    2/0 5/0 5/1 5/2 5/3
          SIB0_Plane 1
               Link errors  FPC/PFEs    2/0 5/0
        PFE #1
          SIB0_Plane 0
               Link errors  FPC/PFEs    2/0 5/0 5/1 5/2 5/3
          SIB0_Plane 1
               Link errors  FPC/PFEs    2/0 5/0