    request chassis redundancy feb slot

    Syntax

    request chassis redundancy feb slot slot-number (switch-to-backup | revert-from-backup)

    Release Information

    Command introduced in Junos OS Release 8.2.

    Description

    (M120 routers only) Control the operation of the specified Forwarding Engine Board (FEB) in a redundancy group.

    Options

    slot-number

    FEB slot number. Replace slot-number with a value from 0 through 5.

    switch-to-backup

    Initiate a switchover from the specified active FEB to the backup FEB for the redundancy group.

    revert-from-backup

    Initiate a revert to the specified FEB following a switchover to the backup FEB for a redundancy group.

    Required Privilege Level

    maintenance

    List of Sample Output

    request chassis redundancy feb slot 2 switch-to-backup
    request chassis redundancy feb slot 3 revert-to-backup

    Output Fields

    When you enter this command, you are provided feedback on the status of your request.

    Sample Output

    request chassis redundancy feb slot 2 switch-to-backup

    user@host> request chassis redundancy feb slot 2 switch-to-backup
    Switch initiated, use “show chassis redundancy febs” to verify

    request chassis redundancy feb slot 3 revert-to-backup

    user@host> request chassis redundancy feb slot 3 revert-to-backup
    Revert initiated, use “show chassis redundancy febs” to verify