Help us improve your experience.

Let us know what you think.

Do you have time for a two-minute survey?

Navigation
Guide That Contains This Content
[+] Expand All
[-] Collapse All

    Example: Configuring Ethernet OAM Connectivity Fault Management on EX Series Switches

    Ethernet interfaces on Juniper Networks EX Series Ethernet Switches and Juniper Networks Junos OS for EX Series switches support the IEEE 802.1ag standard for Operation, Administration, and Management (OAM). The IEEE 802.1ag specification provides for Ethernet connectivity fault management (CFM).

    This example describes how to enable and configure OAM CFM on a Gigabit Ethernet interface:

    Requirements

    This example uses the following hardware and software components:

    • Junos OS Release 10.2 or later for EX Series switches
    • Two EX Series switches connected by a point-to-point Gigabit Ethernet link

    Overview and Topology

    CFM can be used to monitor the physical link between two switches. In the following example, two switches are connected by a point-to-point Gigabit Ethernet link. The link between these two switches is monitored using CFM.

    Configuring Ethernet OAM Connectivity Fault Management on Switch 1

    CLI Quick Configuration

    To quickly configure Ethernet OAM CFM, copy the following commands and paste them into the switch terminal window:

    [edit protocols oam ethernet connectivity-fault-management maintenance-domain]set name-format character-string set maintenance-domain private level 0set maintenance-association private-maset continuity-check hold-interval 1s

    Step-by-Step Procedure

    To enable and configure OAM CFM on switch 1:

    1. Specify the maintenance domain name format:
      [edit protocols oam ethernet connectivity-fault-management maintenance-domain]user@switch1# set name-format character-string
    2. Specify the maintenance domain name and the maintenance domain level:
      [edit protocols oam ethernet connectivity-fault-management]user@switch1# set maintenance-domain private level 0
    3. Create a maintenance association:
      [edit protocols oam ethernet connectivity-fault-management maintenance-domain private]user@switch1# set maintenance-association private-ma
    4. Enable the continuity check protocol and specify the continuity check hold interval:
      [edit protocols oam ethernet connectivity-fault-management maintenance-domain private maintenance-association private-ma]user@switch1# set continuity-check hold-interval 1s
    5. Configure the maintenance association end point (MEP):
      [edit protocols oam ethernet connectivity-fault-management maintenance-domain private maintenance-association private-ma] user@switch1# set mep 100 interface ge-1/0/1 auto-discovery direction down

    Results

    Check the results of the configuration.

    [edit]
    user@switch1# show
    protocols {oam {ethernet {connectivity-fault-management {maintenance-domain private {level 0;maintenance-association private-ma {continuity-check {interval 1s;}mep 100 {interface ge-1/0/1;auto-discovery;direction down;}}}}}

    Configuring Ethernet OAM Connectivity Fault Management on Switch 2

    CLI Quick Configuration

    To quickly configure Ethernet OAM CFM, copy the following commands and paste them into the switch terminal window:

    [edit protocols oam ethernet connectivity-fault-management maintenance-domain]set name-format character-string set maintenance-domain private level 0set maintenance-association private-maset continuity-check hold-interval 1s

    Step-by-Step Procedure

    The configuration on switch 2 mirrors that on switch 2.

    1. Specify the maintenance domain name format:
      [edit protocols oam ethernet connectivity-fault-management]user@switch2# set name-format character-string
    2. Specify the maintenance domain name and the maintenance domain level:
      [edit protocols oam ethernet connectivity-fault-management]user@switch2# set maintenance-domain private level 0
    3. Create a maintenance association:
      [edit protocols oam ethernet connectivity-fault-management maintenance-domain private]user@switch2# set maintenance-association private-ma
    4. Enable the continuity check protocol and specify the continuity check hold interval:
      [edit protocols oam ethernet connectivity-fault-management maintenance-domain private maintenance-association private-ma]user@switch2# set continuity-check hold-interval 1s
    5. Configure the maintenance association end point (MEP)
      [edit protocols oam ethernet connectivity-fault-management maintenance-domain private maintenance-association private-ma] user@switch2# set mep 100 interface ge-0/2/5 auto-discovery direction down

    Results

    Check the results of the configuration.

    [edit]
    user@switch2# show
    protocols {oam {ethernet {connectivity-fault-management {maintenance-domain private {level 0;maintenance-association private-ma {continuity-check {interval 1s;}mep 100 {interface ge-0/2/5;auto-discovery;direction down;}}}}}

    Verification

    To confirm that the configuration is working properly, perform these tasks:

    Verifying That OAM CFM Has Been Configured Properly

    Purpose

    Verify that OAM CFM has been configured properly.

    Action

    Use the show oam ethernet connectivity-fault-management interfaces detail command:

    Sample Output

    Interface name: ge-1/0/1.0, Interface status: Active, Link status: Up
      Maintenance domain name: private, Format: string, Level: 0
        Maintenance association name: private-ma, Format: string
        Continuity-check status: enabled, Interval: 1ms, Loss-threshold: 3 frames
        MEP identifier: 100, Direction: down, MAC address: 00:90:69:0b:4b:94
        MEP status: running
        Defects:
          Remote MEP not receiving CCM                  : no
          Erroneous CCM received                        : yes
          Cross-connect CCM received                    : no
          RDI sent by some MEP                          : yes
        Statistics:
          CCMs sent                                     : 76
          CCMs received out of sequence                 : 0
          LBMs sent                                     : 0
          Valid in-order LBRs received                  : 0
          Valid out-of-order LBRs received              : 0
          LBRs received with corrupted data             : 0
          LBRs sent                                     : 0
          LTMs sent                                     : 0
          LTMs received                                 : 0
          LTRs sent                                     : 0
          LTRs received                                 : 0
          Sequence number of next LTM request           : 0
        Remote MEP count: 2
          Identifier    MAC address        State    Interface
           2001     00:90:69:0b:7f:71       ok    ge-0/2/5.0
           

    Meaning

    When the output displays continuity-check status is enabled and displays details of the remote MEP, it means that connectivity fault management (CFM) has been configured properly.

    Published: 2012-12-07