    Example: Setting Up 802.1X in Conference Rooms to Provide Internet Access to Corporate Visitors on an EX Series Switch

    802.1X on EX Series switches provides LAN access to users who do not have credentials in the RADIUS database. These users, referred to as guests, are authenticated and typically provided with access to the Internet.

    This example describes how to create a guest VLAN and configure 802.1X authentication for it.

    Requirements

    This example uses the following hardware and software components:

    • Junos OS Release 9.0 or later for EX Series switches
    • One EX Series switch acting as an authenticator interface access entity (PAE). The interfaces on the authenticator PAE form a control gate that blocks all traffic to and from supplicants until they are authenticated.
    • One RADIUS authentication server that supports 802.1X. The authentication server acts as the backend database and contains credential information for hosts (supplicants) that have permission to connect to the network.

    Before you configure guest VLAN authentication, be sure you have:

    Overview and Topology

    As part of IEEE 802.1X Port-Based Network Access Control (PNAC), you can provide limited network access to supplicants who do not belong to a VLAN authentication group by configuring authentication to a guest VLAN. Typically, guest VLAN access is used to provide Internet access to visitors to a corporate site. However, you can also use the guest VLAN feature to provide supplicants that fail 802.1X authentication to a corporate LAN with access to a VLAN with limited resources.

    Figure 1 shows the conference room connected to the switch at interface ge-0/0/1.

    Figure 1: Topology for Guest VLAN Example

    Topology for Guest VLAN Example

    Table 1: Components of the Guest VLAN Topology

    PropertySettings

    Switch hardware

    EX4200 switch, 24 Gigabit Ethernet interfaces: 8 PoE interfaces (ge-0/0/0 through ge-0/0/7) and 16 non-PoE interfaces (ge-0/0/8 through ge-0/0/23)

    VLAN names and tag IDs

    sales, tag 100
    support, tag 200

    guest-vlan, tag 300

    One RADIUS server

    Backend database connected to the switch through interface ge-0/0/10

    In this example, access interface ge-0/0/1 provides LAN connectivity in the conference room. Configure this access interface to provide LAN connectivity to visitors in the conference room who are not authenticated by the corporate VLAN.

    Configuration of a Guest VLAN That Includes 802.1X Authentication

    To create a guest VLAN and configure 802.1X authentication, perform these tasks:

    CLI Quick Configuration

    To quickly configure a guest VLAN, with 802.1X authentication, copy the following commands and paste them into the switch terminal window:

    [edit]
    set vlans guest-vlan vlan-id 300
    set protocols dot1x authenticator interface all guest-vlan guest-vlan

    Step-by-Step Procedure

    To configure a guest VLAN that includes 802.1X authentication on an EX Series switch:

    1. Configure the VLAN ID for the guest VLAN:
      [edit]

      user@switch# set vlans guest-vlan vlan-id 300
    2. Configure the guest VLAN under dot1x protocols:
      [edit]

      user@switch# set protocols dot1x authenticator interface all guest-vlan guest-vlan

    Results

    Check the results of the configuration:

    user@switch> show configuration protocols {dot1x {authenticator {interface {all {guest-vlan {guest-vlan;}}}}}}vlans {guest-vlan {vlan-id 300;}}

    Verification

    To confirm that the configuration is working properly, perform these tasks:

    Verifying That the Guest VLAN is Configured

    Purpose

    Verify that the guest VLAN is created and that an interface has failed authentication and been moved to the guest VLAN.

    Action

    Use the operational mode commands:

    user@switch> show vlans
    Name           Tag     Interfaces
    default       
                           ge-0/0/3.0*
    dynamic        40      
                           None
    guest          30      
                           None
    guest—vlan     300
                           ge-0/0/1.0*
    vlan_dyn      
                           None
    
    
    user@switch> show dot1x interface ge-0/0/1.0 detail
    ge-0/0/1.0
      Role: Authenticator
      Administrative state: Auto
      Supplicant mode: Single
      Number of retries: 3
      Quiet period: 60 seconds
      Transmit period: 30 seconds
      Mac Radius: Enabled
      Mac Radius Restrict: Disabled
      Reauthentication: Enabled
      Configured Reauthentication interval: 3600 seconds
      Supplicant timeout: 30 seconds
      Server timeout: 30 seconds
      Maximum EAPOL requests: 2
      Guest VLAN member: guest-vlan
      Number of connected supplicants: 1
        Supplicant: user1, 00:00:00:00:13:23
          Operational state: Authenticated
          Authentication method: Radius
          Authenticated VLAN: vo11
          Dynamic Filter: match source-dot1q-tag 10 action deny
          Session Reauth interval: 60 seconds
          Reauthentication due in 50 seconds
    

    Meaning

    The output from the show vlans command shows guest-vlan as the the name of the VLAN and the VLAN ID as 300.

    The output from the show dot1x interface ge-0/0/1.0 detail command displays the Guest VLAN membership field, indicating that a supplicant at this interface failed 802.1X authentication and was passed through to the guest-vlan.