Navigation
Table of Contents
Guide That Contains This Content
[+] Expand All
[-] Collapse All
Verifying That Uplink Failure Detection Is Working Correctly
Purpose
Verify that the switch disables the downlink interface when it detects an uplink failure.
Action
- View the current uplink failure detection status:
user@switch> show uplink-failure-detectionGroup : group1 Uplink : xe-0/0/0* Downlink : xe-0/0/1* Failure Action : Inactive

Note: The asterisk (*) indicates that the link is up.
- Disable the uplink interface:
[edit]
user@switch# set interface xe-0/0/0 disable - Save the configuration on the switch.
- View the current uplink failure detection status:
user@switch> show uplink-failure-detectionGroup : group1 Uplink : xe-0/0/0 Downlink : xe-0/0/1 Failure Action : Active
Meaning
The output in Step 1 shows that the uplink interface is up, and hence that the downlink interface is also up, and that the status of Failure Action is Inactive.