Help us improve your experience.

Let us know what you think.

Do you have time for a two-minute survey?

Navigation
Guide That Contains This Content
[+] Expand All
[-] Collapse All

    Display the Status of a Specific T1 Interface

    Purpose

    To display the status of a specific T1 interface when you need to investigate its status further.

    Action

    To display the status of a specific T1 interface, use the following Junos OS CLI operational mode command:

    user@host> show interfaces t1-fpc/pic/port

    Sample Output

    user@host> show interfaces t1-1/1/0
    Physical interface: t1-1/1/0, Enabled,Physical link is Down
      Interface index: 24, SNMP ifIndex: 20
      Link-level type: PPP, MTU: 1504, Clocking: Internal, Speed: T1, Loopback: None, FCS: 16, Framing: ESF
      Device flags   : Present Running Down
      Interface flags: Hardware-Down Point-To-Point SNMP-Traps
      Link flags     : Keepalives
      Last flapped   : 2002-01-01 00:00:35 UTC (00:00:59 ago)
      Input rate     : 0 bps (0 pps)
      Output rate    : 0 bps (0 pps)
      DS1   alarms   : LOF, LOS
      DS1   defects  : LOF, LOS
    
    

    Meaning

    The first line of the sample output shows the status of the link. In this example, the first line shows that the physical link is down. If the first line shows that the physical link is up, the physical link is healthy and can pass packets. If this line shows that the physical link is down, the physical link is unhealthy and cannot pass packets. Also, the output shows loss of frame (LOF) and loss of signal (LOS) alarms active. Any active alarm or defect can cause the interface to be down.