Verifying Nonstop Software Upgrade for QFabric Systems
This topic discusses how you can monitor the progress of each of the three steps in a nonstop software upgrade. By identifying the key actions and events that define this process, you can track the status of the upgrade with confidence.
![]() | Tip: When performing a nonstop software upgrade, open two SSH sessions to the QFabric CLI. Use one session to monitor the upgrade itself and use a second session to verify that the QFabric system components respond to operational mode commands as expected. |
Verifying a Director Group Nonstop Software Upgrade
Purpose
During the Director group portion of a nonstop software upgrade, you should expect to see the Director device that hosts the CLI session selected as the master device. When mastership of all processes moves to the master, the QFabric system upgrades the backup Director device and this Director device reboots. After the backup Director device comes back online, the master Director device suspends CLI operations for 15 minutes, upgrades itself, and reboots. At this point, the backup becomes the new master Director device and you can issue CLI operational commands. Finally, the former master comes back online as a backup and both devices are operational once again.
Action
- In one SSH session to the QFabric CLI, verify the current
status of the QFabric system by issuing the show fabric administration
inventory, show fabric administration inventory director-group
status, and show fabric session-host commands. In
this case, Director device DG0 is the master device but DG1 hosts
the CLI session.
session1@qfabric> show fabric administration inventoryItem Identifier Connection Configuration Node group NW-NG-0 Connected Configured P1507-C Connected RSNG Connected Configured P1550-C Connected P1571-C Connected Interconnect device IC-F4912 Connected Configured F4912/RE0 Connected Fabric manager FM-0 Connected Configured Fabric control FC-0 Connected Configured FC-1 Connected Configured Diagnostic routing engine DRE-0 Connected Configuredsession1@qfabric> show fabric administration inventory director-group statusDirector Group Status Tue Jun 5 15:11:26 UTC 2012 Member Status Role Mgmt Address CPU Free Memory VMs Up Time ------ ------ -------- --------------- --- ----------- --- ------------- dg0 online master 10.49.215.38 8% 17363152k 4 3 days, 20:55 hrs dg1 online backup 10.49.215.39 6% 20157440k 3 3 days, 20:55 hrs Member Device Id/Alias Status Role ------ ---------------- ------- --------- dg0 0281052011000001 online master Master Services --------------- Database Server online Load Balancer Director online QFabric Partition Address online Director Group Managed Services ------------------------------- Shared File System online Network File System online Virtual Machine Server online Load Balancer/DHCP online Hard Drive Status ---------------- Volume ID:4 optimal Physical ID:1 online Physical ID:0 online SCSI ID:1 100% SCSI ID:0 100% Size Used Avail Used% Mounted on ---- ---- ----- ----- ---------- 423G 5.4G 395G 2% / 99M 16M 79M 17% /boot 93G 7.3G 86G 8% /pbdata Director Group Processes ------------------------ Director Group Manager online Partition Manager online Software Mirroring online Shared File System master online Secure Shell Process online Network File System online DHCP Server master online master FTP Server online Syslog online Distributed Management online SNMP Trap Forwarder online SNMP Process online Platform Management online Interface Link Status --------------------- Management Interface up Control Plane Bridge up Control Plane LAG up CP Link [0/2] up CP Link [0/1] up CP Link [0/0] up CP Link [1/2] down CP Link [1/1] down CP Link [1/0] down Crossover LAG up CP Link [0/3] up CP Link [1/3] up Member Device Id/Alias Status Role ------ ---------------- ------- --------- dg1 0281052011000032 online backup Director Group Managed Services ------------------------------- Shared File System online Network File System online Virtual Machine Server online Load Balancer/DHCP online Hard Drive Status ---------------- Volume ID:8 optimal Physical ID:1 online Physical ID:0 online SCSI ID:1 100% SCSI ID:0 100% Size Used Avail Used% Mounted on ---- ---- ----- ----- ---------- 423G 5.5G 395G 2% / 99M 16M 79M 17% /boot 93G 7.3G 86G 8% /pbdata Director Group Processes ------------------------ Director Group Manager online Partition Manager online Software Mirroring online Shared File System master online Secure Shell Process online Network File System online DHCP Server master online backup FTP Server online Syslog online Distributed Management online SNMP Trap Forwarder online SNMP Process online Platform Management online Interface Link Status --------------------- Management Interface up Control Plane Bridge up Control Plane LAG up CP Link [0/2] up CP Link [0/1] up CP Link [0/0] up CP Link [1/2] down CP Link [1/1] down CP Link [1/0] down Crossover LAG up CP Link [0/3] up CP Link [1/3] up
session1@qfabric> show fabric session-hostIdentifier: 0281052011000032
- In a second SSH session to the QFabric CLI, issue the
request for the Director group nonstop software upgrade.
root@qfabric> request system software nonstop-upgrade director-group jinstall-qfabric-12.2X50-D10.3.rpm - If the CLI session is being hosted by the master Director
device, skip to step 4. However, if the CLI session is hosted by the
backup Director device, the Director group mastership switches to
the backup device after you issue the nonstop software upgrade command.
In this example, mastership switches to Director device DG1.
session1@qfabric> show fabric administration inventory director-group statusDirector Group Status Tue Jun 5 15:12:20 UTC 2012 Member Status Role Mgmt Address CPU Free Memory VMs Up Time ------ ------ -------- --------------- --- ----------- --- ------------- dg0 online backup 10.49.215.38 8% 31905924k 0 3 days, 21:16 hrs dg1 online master 10.49.215.39 6% 18010368k 3 3 days, 21:16 hrs Member Device Id/Alias Status Role ------ ---------------- ------- --------- dg0 0281052011000001 online backup Director Group Managed Services ------------------------------- Shared File System offline Network File System offline Virtual Machine Server offline Load Balancer/DHCP offline Hard Drive Status ---------------- Volume ID:4 optimal Physical ID:1 online Physical ID:0 online SCSI ID:1 100% SCSI ID:0 100% Size Used Avail Used% Mounted on ---- ---- ----- ----- ---------- 423G 5.4G 395G 2% / 99M 16M 79M 17% /boot Director Group Processes ------------------------ Director Group Manager online Partition Manager online Software Mirroring online Shared File System master online Secure Shell Process online Network File System offline DHCP Server master offline backup FTP Server online Syslog online Distributed Management offline SNMP Trap Forwarder offline SNMP Process offline Platform Management online Interface Link Status --------------------- Management Interface up Control Plane Bridge up Control Plane LAG up CP Link [0/2] up CP Link [0/1] up CP Link [0/0] up CP Link [1/2] down CP Link [1/1] down CP Link [1/0] down Crossover LAG up CP Link [0/3] up CP Link [1/3] up Member Device Id/Alias Status Role ------ ---------------- ------- --------- dg1 0281052011000032 online master Master Services --------------- Database Server online Load Balancer Director online QFabric Partition Address online Director Group Managed Services ------------------------------- Shared File System online Network File System online Virtual Machine Server online Load Balancer/DHCP online Hard Drive Status ---------------- Volume ID:8 optimal Physical ID:1 online Physical ID:0 online SCSI ID:1 100% SCSI ID:0 100% Size Used Avail Used% Mounted on ---- ---- ----- ----- ---------- 423G 6.0G 395G 2% / 99M 16M 79M 17% /boot 93G 7.3G 86G 8% /pbdata Director Group Processes ------------------------ Director Group Manager online Partition Manager online Software Mirroring online Shared File System master online Secure Shell Process online Network File System online DHCP Server master online master FTP Server online Syslog online Distributed Management online SNMP Trap Forwarder online SNMP Process online Platform Management online Interface Link Status --------------------- Management Interface up Control Plane Bridge up Control Plane LAG up CP Link [0/2] up CP Link [0/1] up CP Link [0/0] up CP Link [1/2] down CP Link [1/1] down CP Link [1/0] down Crossover LAG up CP Link [0/3] up CP Link [1/3] upsession1@qfabric> show fabric session-hostIdentifier: 0281052011000032
- The Director group nonstop software upgrade process continues
by downloading and installing software for the fabric manager Routing
Engines and the Director devices.
root@qfabric>Validating update package jinstall-qfabric-12.2X50-D10.3.rpm Installing update package jinstall-qfabric-12.2X50-D10.3.rpm Installing fabric images version 12.2X50-D10.3 Performing cleanup Package install complete Installing update package jinstall-qfabric-12.2X50-D10.3.rpm on peer Triggering Initial Stage of Fabric Manager Upgrade Updating CCIF default image to 12.2X50-D10.3 Updating FM-0 to Junos version 12.2X50-D10.3 [Status 2012-06-05 15:25:29]: Fabric Manager: Upgrade Initial Stage started [FM-0 2012-06-05 15:25:38]: FM-0 Master already running on LOCAL DG [NW-NG-0 2012-06-05 15:25:45]: NW-NG-0 Master already running on LOCAL DG [FM-0 2012-06-05 15:26:12]: Retrieving package [FM-0 2012-06-05 15:27:11]: Pushing bundle to re0 [Status 2012-06-05 15:29:06]: Load completed with 0 errors... [Status 2012-06-05 15:29:06]: Reboot is required to complete upgrade ... [Status 2012-06-05 15:29:07]: Trying to Connect to Node: FM-0 [Status 2012-06-05 15:29:13]: Rebooting FM-0 [FM-0 2012-06-05 15:29:13]: Waiting for FM-0 to terminate ... Starting Peer upgrade Initiating rolling upgrade of Director peer: version 12.2X50-D10.3 Inform CCIF regarding rolling upgrade [Peer Update Status]: Validating install package jinstall-qfabric-12.2X50-D10.3.rpm [Peer Update Status]: Cleaning up node for rolling phase one upgrade [Peer Update Status]: Director group upgrade complete [Peer Update Status]: COMPLETED [Peer Update Status]: Waiting for peer to reboot and start phase one of rolling upgrade [Peer Update Status]: Waiting for peer to reboot and start phase one of rolling upgrade [Peer Update Status]: Waiting for peer to reboot and start phase one of rolling upgrade [Peer Update Status]: Waiting for peer to reboot and start phase one of rolling upgrade [Peer Update Status]: Waiting for peer to reboot and start phase one of rolling upgrade [Peer Update Status]: Waiting for peer to reboot and start phase one of rolling upgrade [Peer Update Status]: Waiting for peer to reboot and start phase one of rolling upgrade [Peer Update Status]: Waiting for peer to reboot and start phase one of rolling upgrade [Peer Update Status]: Waiting for peer to reboot and start phase one of rolling upgrade [Peer Update Status]: Waiting for peer to reboot and start phase one of rolling upgrade [Peer Update Status]: Waiting for peer to return after reboot and start phase one of rolling upgrade [Peer Update Status]: Waiting for peer to return after reboot and start phase one of rolling upgrade [Peer Update Status]: Waiting for peer to return after reboot and start phase one of rolling upgrade [Peer Update Status]: Waiting for peer to return after reboot and start phase one of rolling upgrade [Peer Update Status]: Waiting for peer to return after reboot and start phase one of rolling upgrade [Peer Update Status]: Waiting for peer to return after reboot and start phase one of rolling upgrade [Peer Update Status]: Waiting for peer to return after reboot and start phase one of rolling upgrade [Peer Update Status]: Waiting for peer to return after reboot and start phase one of rolling upgrade [Peer Update Status]: Waiting for peer to return after reboot and start phase one of rolling upgrade [Peer Update Status]: Waiting for peer to complete phase one of rolling upgrade [Peer Update Status]: Peer completed phase one of rolling upgrade
- When the system upgrades and reboots the backup Director
device DG0, notice how this device is not displayed in the output
of the show fabric administration inventory director-group status command. Because Director device DG1 appears, this means that the
DG1 is operational and acts as the master device.

Note: If your second SSH session is being hosted by the rebooting Director device, your session terminates and you need to log back in to establish a new session running on the active Director device.
session1@qfabric> show fabric administration inventory director-group statusDirector Group Status Tue Jun 5 15:41:14 UTC 2012 Member Status Role Mgmt Address CPU Free Memory VMs Up Time ------ ------ -------- --------------- --- ----------- --- ------------- dg1 online master 10.49.215.39 6% 8372272k 4 3 days, 21:25 hrs Member Device Id/Alias Status Role ------ ---------------- ------- --------- dg1 0281052011000032 online master Master Services --------------- Database Server online Load Balancer Director online QFabric Partition Address online Director Group Managed Services ------------------------------- Shared File System online Network File System online Virtual Machine Server online Load Balancer/DHCP online Hard Drive Status ---------------- Volume ID:8 optimal Physical ID:1 online Physical ID:0 online SCSI ID:1 100% SCSI ID:0 100% Size Used Avail Used% Mounted on ---- ---- ----- ----- ---------- 423G 6.0G 395G 2% / 99M 16M 79M 17% /boot 93G 7.3G 86G 8% /pbdata Director Group Processes ------------------------ Director Group Manager online Partition Manager online Software Mirroring online Shared File System master online Secure Shell Process online Network File System online DHCP Server master online master FTP Server online Syslog online Distributed Management online SNMP Trap Forwarder online SNMP Process online Platform Management online Interface Link Status --------------------- Management Interface up Control Plane Bridge up Control Plane LAG up CP Link [0/2] up CP Link [0/1] up CP Link [0/0] up CP Link [1/2] down CP Link [1/1] down CP Link [1/0] down Crossover LAG up CP Link [0/3] up CP Link [1/3] up
- The upgrade continues with master Director device DG1
suspending CLI services for 15 minutes, transferring mastership to
Director device DG0, and then rebooting Director device DG1 (which
terminates the CLI session).
root@qfabric>[Peer Update Status]: Setting peer DG node as the master SFC Delaying start of local upgrade to allow peer services time to initialize [15 minutes] Delaying start of local upgrade to allow peer services time to initialize [15 minutes] Delaying start of local upgrade to allow peer services time to initialize [12 minutes] Delaying start of local upgrade to allow peer services time to initialize [9 minutes] Delaying start of local upgrade to allow peer services time to initialize [6 minutes] Delaying start of local upgrade to allow peer services time to initialize [3 minutes] [Peer Update Status]: Check for VMs on dg0 Triggering Final Stage of Fabric Manager Upgrade: Updating FM-0 to Junos version 12.2X50-D10.3 [Status 2012-06-05 16:10:12]: Fabric Manager: Upgrade Final Stage started [NW-NG-0 2012-06-05 16:10:22]: Transferring NW-NG-0 Mastership to REMOTE DG [NW-NG-0 2012-06-05 16:11:44]: Finished NW-NG-0 Mastership switch [Status 2012-06-05 16:11:45]: Upgrading FM-0 VM on worker DG to 12.2X50-D10.3 [DRE-0 2012-06-05 16:12:43]: Retrieving package [DRE-0 2012-06-05 16:13:46]: ------- re0: ------- [Status 2012-06-05 16:15:17]: Load completed with 0 errors... [Status 2012-06-05 16:15:17]: Reboot is required to complete upgrade ... [DRE-0 2012-06-05 16:15:22]: Waiting for DRE-0 to terminate ... [DRE-0 2012-06-05 16:15:34]: Waiting for DRE-0 to come back ... [DRE-0 2012-06-05 16:18:44]: Running Uptime Test for DRE-0 [DRE-0 2012-06-05 16:18:51]: Uptime Test for DRE-0 Passed ... [Status 2012-06-05 16:18:51]: DRE-0 booted successfully ... Performing post install shutdown and cleanup Broadcast message from root (Tue Jun 5 16:18:51 2012): The system is going down for reboot NOW! Director group upgrade complete root@qfabric> Read from remote host qfabric-partition0: Connection reset by peer Connection to qfabric-partition0 closed.
- Upon reopening the SSH session, notice that Director device
DG0 is now the master device hosting the session and Director device
DG1 does not appear in the QFabric system inventory while it is rebooting.
session1@qfabric> show fabric session-hostIdentifier: 0281052011000001
session1@qfabric> show fabric administration inventory director-group statusDirector Group Status Tue Jun 5 16:21:23 UTC 2012 Member Status Role Mgmt Address CPU Free Memory VMs Up Time ------ ------ -------- --------------- --- ----------- --- ------------- dg0 online master 10.49.215.38 13% 20739560k 3 36:29 mins Member Device Id/Alias Status Role ------ ---------------- ------- --------- dg0 0281052011000001 online master Master Services --------------- Database Server online Load Balancer Director online QFabric Partition Address online Director Group Managed Services ------------------------------- Shared File System online Network File System online Virtual Machine Server online Load Balancer/DHCP online Hard Drive Status ---------------- Volume ID:4 optimal Physical ID:1 online Physical ID:0 online SCSI ID:1 100% SCSI ID:0 100% Size Used Avail Used% Mounted on ---- ---- ----- ----- ---------- 423G 5.3G 396G 2% / 99M 16M 79M 17% /boot 93G 7.4G 86G 8% /pbdata Director Group Processes ------------------------ Director Group Manager online Partition Manager online Software Mirroring online Shared File System master online Secure Shell Process online Network File System online DHCP Server master online master FTP Server online Syslog online Distributed Management online SNMP Trap Forwarder online SNMP Process online Platform Management online Interface Link Status --------------------- Management Interface up Control Plane Bridge up Control Plane LAG up CP Link [0/2] up CP Link [0/1] up CP Link [0/0] up CP Link [1/2] down CP Link [1/1] down CP Link [1/0] down Crossover LAG up CP Link [0/3] up CP Link [1/3] up
- When Director device DG1 comes back online, it returns
to the QFabric system inventory as a backup Director device and hosts
some of the Routing Engine processes (which should appear load balanced
between the master and backup Director devices).
session1@qfabric> show fabric administration inventory director-group statusroot@qfabric> show fabric administration inventory director-group status Director Group Status Tue Jun 5 16:41:02 UTC 2012 Member Status Role Mgmt Address CPU Free Memory VMs Up Time ------ ------ -------- --------------- --- ----------- --- ------------- dg0 online master 10.49.215.38 15% 14759920k 6 56:09 mins dg1 online backup 10.49.215.39 8% 31486680k 0 07:51 mins Member Device Id/Alias Status Role ------ ---------------- ------- --------- dg0 0281052011000001 online master Master Services --------------- Database Server online Load Balancer Director online QFabric Partition Address online Director Group Managed Services ------------------------------- Shared File System online Network File System online Virtual Machine Server online Load Balancer/DHCP online Hard Drive Status ---------------- Volume ID:4 optimal Physical ID:1 online Physical ID:0 online SCSI ID:1 100% SCSI ID:0 100% Size Used Avail Used% Mounted on ---- ---- ----- ----- ---------- 423G 5.3G 396G 2% / 99M 16M 79M 17% /boot 93G 7.4G 86G 8% /pbdata Director Group Processes ------------------------ Director Group Manager online Partition Manager online Software Mirroring online Shared File System master online Secure Shell Process online Network File System online DHCP Server master online master FTP Server online Syslog online Distributed Management online SNMP Trap Forwarder online SNMP Process online Platform Management online Interface Link Status --------------------- Management Interface up Control Plane Bridge up Control Plane LAG up CP Link [0/2] up CP Link [0/1] up CP Link [0/0] up CP Link [1/2] down CP Link [1/1] down CP Link [1/0] down Crossover LAG up CP Link [0/3] up CP Link [1/3] up Member Device Id/Alias Status Role ------ ---------------- ------- --------- dg1 0281052011000032 online backup Director Group Managed Services ------------------------------- Shared File System online Network File System online Virtual Machine Server online Load Balancer/DHCP online Hard Drive Status ---------------- Volume ID:8 optimal Physical ID:1 online Physical ID:0 online SCSI ID:1 100% SCSI ID:0 100% Size Used Avail Used% Mounted on ---- ---- ----- ----- ---------- 423G 5.3G 396G 2% / 99M 16M 79M 17% /boot 93G 7.4G 86G 8% /pbdata Director Group Processes ------------------------ Director Group Manager online Partition Manager online Software Mirroring online Shared File System master online Secure Shell Process online Network File System online DHCP Server master online backup FTP Server online Syslog online Distributed Management online SNMP Trap Forwarder online SNMP Process online Platform Management online Interface Link Status --------------------- Management Interface up Control Plane Bridge up Control Plane LAG up CP Link [0/2] up CP Link [0/1] up CP Link [0/0] up CP Link [1/2] down CP Link [1/1] down CP Link [1/0] down Crossover LAG up CP Link [0/3] up CP Link [1/3] up
session1@qfabric> show fabric administration inventory infrastructuredg0: Routing Engine Type Hostname PID CPU-Use(%) ------------------------- --------------------------------- ---------- ------------- Fabric control QFabric_default_FC-1_RE0 27906 2.5 Network Node group QFabric_default_NW-NG-1_RE1 20421 1.8 Fabric manager FM-0 4211 1.8 Debug Routing Engine QFabric_DRE 1575 3.3 dg1: Routing Engine Type Hostname PID CPU-Use(%) ------------------------- --------------------------------- ---------- ------------- Fabric control QFabric_default_FC-0_RE0 5686 2.3 Network Node group QFabric_default_NW-NG-0_RE0 5866 1.9 Fabric manager FM-1 572 1.6
Meaning
Verifying a Fabric Nonstop Software Upgrade
Purpose
During the fabric portion of a nonstop software upgrade, you should expect to see both fabric control Routing Engines upgrade first, followed by the upgrade of each Interconnect device one at a time.
Action
- In an SSH session to the QFabric CLI, issue the request
for the fabric nonstop software upgrade.
root@qfabric> request system software nonstop-upgrade fabric jinstall-qfabric-12.2X50-D10.3.rpm[FC-0 2012-06-05 16:48:53]: Retrieving package [FC-1 2012-06-05 16:48:53]: Retrieving package [IC-F4912 2012-06-05 16:48:59]: Retrieving package [FC-0 2012-06-05 16:49:51]: ------- re0: ------- [FC-1 2012-06-05 16:49:52]: ------- re0: ------- [IC-F4912 2012-06-05 16:49:54]: ------- re0: ------- [IC-F4912 2012-06-05 16:50:42]: Step 1 of 20 Creating temporary file system [IC-F4912 2012-06-05 16:50:42]: Step 2 of 20 Determining installation source [IC-F4912 2012-06-05 16:50:43]: Step 3 of 20 Processing format options [IC-F4912 2012-06-05 16:50:43]: Step 4 of 20 Determining installation slice [IC-F4912 2012-06-05 16:50:43]: Step 5 of 20 Creating and labeling new slices [IC-F4912 2012-06-05 16:50:44]: Step 6 of 20 Create and mount new file system [IC-F4912 2012-06-05 16:50:53]: Step 7 of 20 Getting OS bundles [IC-F4912 2012-06-05 16:50:53]: Step 8 of 20 Updating recovery media [IC-F4912 2012-06-05 16:51:17]: Step 9 of 20 Extracting incoming image [IC-F4912 2012-06-05 16:52:56]: Step 10 of 20 Unpacking OS packages [IC-F4912 2012-06-05 16:52:59]: Step 11 of 20 Mounting jbase package [IC-F4912 2012-06-05 16:53:28]: Step 12 of 20 Creating base OS symbolic links [IC-F4912 2012-06-05 16:54:45]: Step 13 of 20 Creating fstab [IC-F4912 2012-06-05 16:54:45]: Step 14 of 20 Creating new system files [IC-F4912 2012-06-05 16:54:46]: Step 15 of 20 Adding jbundle package [IC-F4912 2012-06-05 16:58:15]: Step 16 of 20 Backing up system data [IC-F4912 2012-06-05 16:58:18]: Step 17 of 20 Setting up shared partition data [IC-F4912 2012-06-05 16:58:18]: Step 18 of 20 Checking package sanity in installation [IC-F4912 2012-06-05 16:58:18]: Step 19 of 20 Unmounting and cleaning up temporary file systems [IC-F4912 2012-06-05 16:58:22]: Step 20 of 20 Setting da0s1 as new active partition [Status 2012-06-05 16:58:34]: Load completed with 0 errors... [Status 2012-06-05 16:58:34]: Reboot is required to complete upgrade ... [Status 2012-06-05 16:58:34]: Trying to Connect to Node: FC-0 [Status 2012-06-05 16:58:39]: Rebooting FC-0 [Status 2012-06-05 16:58:39]: Trying to Connect to Node: FC-1 [Status 2012-06-05 16:58:44]: Rebooting FC-1 [Status 2012-06-05 16:58:44]: Trying to Connect to Node: IC-F4912 [Status 2012-06-05 16:58:50]: Rebooting IC-F4912 Success
- When the fabric components reboot, they appear as Disconnected in the output of the show fabric
administration inventory infrastructure fabric-controls and show fabric administration inventory interconnect-devices commands.
session1@qfabric> show fabric administration inventory infrastructure fabric-controlsItem Identifier Connection Configuration Fabric control FC-0 Disconnected FC-1 Disconnected
session1@qfabric> show fabric administration inventory interconnect-devices IC-F4912Item Identifier Connection Configuration Interconnect device IC-F4912 Disconnected F4912/RE0 Disconnected - When the fabric components return to full service, they
appear as Connected in the output of
the show fabric administration inventory command.
session1@qfabric> show fabric administration inventoryItem Identifier Connection Configuration Node group NW-NG-0 Connected Configured P1507-C Connected RSNG Connected Configured P1550-C Connected P1571-C Connected Interconnect device IC-F4912 Connected Configured F4912/RE0 Connected Fabric manager FM-0 Connected Configured Fabric control FC-0 Connected Configured FC-1 Connected Configured Diagnostic routing engine DRE-0 Connected Configured
Meaning
Verifying a Redundant Server Node Group Nonstop Software Upgrade
Purpose
During the redundant server Node group portion of a nonstop software upgrade, you should expect to see the backup Node device upgrade first, followed by the upgrade of the master Node device. Server Node groups with a single device upgrade the device in the same way as a standalone switch.
Action
- In an SSH session to the QFabric CLI, issue the request
for the redundant server Node group nonstop software upgrade.
root@qfabric> request system software nonstop-upgrade node-group RSNG jinstall-qfabric-12.2X50-D10.3.rpmUpgrading target(s): RSNG [RSNG 2012-06-05 17:26:44]: Starting with package ftp://169.254.0.3/pub/images/12.2X50-D10.3/jinstall-qfx.tgz [RSNG 2012-06-05 17:26:44]: Retrieving package [RSNG 2012-06-05 17:28:56]: Pushing bundle to fpc1 [RSNG 2012-06-05 17:29:26]: fpc1: Validate package... [RSNG 2012-06-05 17:35:22]: fpc0: Validate package... [RSNG 2012-06-05 17:35:49]: ------- fpc1 ------- [RSNG 2012-06-05 17:36:25]: Step 1 of 20 Creating temporary file system [RSNG 2012-06-05 17:36:26]: Step 2 of 20 Determining installation source [RSNG 2012-06-05 17:36:26]: Step 3 of 20 Processing format options [RSNG 2012-06-05 17:36:26]: Step 4 of 20 Determining installation slice [RSNG 2012-06-05 17:36:27]: Step 5 of 20 Creating and labeling new slices [RSNG 2012-06-05 17:36:27]: Step 6 of 20 Create and mount new file system [RSNG 2012-06-05 17:36:35]: Step 7 of 20 Getting OS bundles [RSNG 2012-06-05 17:36:35]: Step 8 of 20 Updating recovery media [RSNG 2012-06-05 17:36:56]: Step 9 of 20 Extracting incoming image [RSNG 2012-06-05 17:38:07]: Step 10 of 20 Unpacking OS packages [RSNG 2012-06-05 17:38:16]: Step 11 of 20 Mounting jbase package [RSNG 2012-06-05 17:38:41]: Step 12 of 20 Creating base OS symbolic links [RSNG 2012-06-05 17:39:41]: Step 13 of 20 Creating fstab [RSNG 2012-06-05 17:39:42]: Step 14 of 20 Creating new system files [RSNG 2012-06-05 17:39:42]: Step 15 of 20 Adding jbundle package [RSNG 2012-06-05 17:42:16]: Step 16 of 20 Backing up system data [RSNG 2012-06-05 17:42:32]: Step 17 of 20 Setting up shared partition data [RSNG 2012-06-05 17:42:33]: Step 18 of 20 Checking package sanity in installation [RSNG 2012-06-05 17:42:33]: Step 19 of 20 Unmounting and cleaning up temporary file systems [RSNG 2012-06-05 17:42:36]: Step 20 of 20 Setting da0s2 as new active partition [RSNG 2012-06-05 17:42:51]: ------- fpc0 - master ------- [RSNG 2012-06-05 17:42:51]: Step 1 of 20 Creating temporary file system [RSNG 2012-06-05 17:42:51]: Step 2 of 20 Determining installation source [RSNG 2012-06-05 17:42:51]: Step 3 of 20 Processing format options [RSNG 2012-06-05 17:42:51]: Step 4 of 20 Determining installation slice [RSNG 2012-06-05 17:42:51]: Step 5 of 20 Creating and labeling new slices [RSNG 2012-06-05 17:42:51]: Step 6 of 20 Create and mount new file system [RSNG 2012-06-05 17:42:51]: Step 7 of 20 Getting OS bundles [RSNG 2012-06-05 17:42:51]: Step 8 of 20 Updating recovery media [RSNG 2012-06-05 17:42:51]: Step 9 of 20 Extracting incoming image [RSNG 2012-06-05 17:42:51]: Step 10 of 20 Unpacking OS packages [RSNG 2012-06-05 17:42:51]: Step 11 of 20 Mounting jbase package [RSNG 2012-06-05 17:42:51]: Step 12 of 20 Creating base OS symbolic links [RSNG 2012-06-05 17:42:51]: Step 13 of 20 Creating fstab [RSNG 2012-06-05 17:42:51]: Step 14 of 20 Creating new system files [RSNG 2012-06-05 17:42:51]: Step 15 of 20 Adding jbundle package [RSNG 2012-06-05 17:42:51]: Step 16 of 20 Backing up system data [RSNG 2012-06-05 17:42:51]: Step 17 of 20 Setting up shared partition data [RSNG 2012-06-05 17:42:51]: Step 18 of 20 Checking package sanity in installation [RSNG 2012-06-05 17:42:51]: Step 19 of 20 Unmounting and cleaning up temporary file systems [RSNG 2012-06-05 17:42:51]: Step 20 of 20 Setting da0s2 as new active partition [RSNG 2012-06-05 17:43:36]: Rebooting Backup RE [RSNG 2012-06-05 17:43:36]: ------- Rebooting fpc1 ------- [RSNG 2012-06-05 17:50:12]: Initiating Chassis In-Service-Upgrade [RSNG 2012-06-05 17:50:33]: Upgrading group: 0 fpc: 0 [RSNG 2012-06-05 17:52:38]: Upgrade complete for group:0 [RSNG 2012-06-05 17:52:38]: Upgrading group: 1 fpc: 1 [RSNG 2012-06-05 17:54:42]: Upgrade complete for group:1 [RSNG 2012-06-05 17:54:42]: Finished processing all upgrade groups, last group :1 [RSNG 2012-06-05 17:54:48]: Preparing for Switchover [RSNG 2012-06-05 17:55:38]: Switchover Completed [Status 2012-06-05 17:55:41]: Upgrade completed with 0 errors Success
- During the redundant server Node group upgrade, the backup
Node device (in this case, P1571-C) is upgraded first and appears
in the Disconnected state in the output
of the show fabric administration inventory command.
session1@qfabric> show fabric administration inventoryItem Identifier Connection Configuration Node group NW-NG-0 Connected Configured P1507-C Connected RSNG Connected Configured P1550-C Connected P1571-C Disconnected Interconnect device IC-F4912 Connected Configured F4912/RE0 Connected Fabric manager FM-0 Connected Configured Fabric control FC-0 Connected Configured FC-1 Connected Configured Diagnostic routing engine DRE-0 Connected Configured - After the backup Node device comes back online, the master
Node device (in this case, P1550-C) appears in the Disconnected state in the output of the show
fabric administration inventory command while the master Node
device upgrades its software.
session1@qfabric> show fabric administration inventoryItem Identifier Connection Configuration Node group NW-NG-0 Connected Configured P1507-C Connected RSNG Connected Configured P1550-C Disconnected P1571-C Connected Interconnect device IC-F4912 Connected Configured F4912/RE0 Connected Fabric manager FM-0 Connected Configured Fabric control FC-0 Connected Configured FC-1 Connected Configured Diagnostic routing engine DRE-0 Connected Configured - After both Node devices in the redundant server Node group
come back online, both Node devices appear as Connected to indicate the successful completion of the Node group nonstop
software upgrade step.
session1@qfabric> show fabric administration inventoryItem Identifier Connection Configuration Node group NW-NG-0 Connected Configured P1507-C Connected RSNG Connected Configured P1550-C Connected P1571-C Connected Interconnect device IC-F4912 Connected Configured F4912/RE0 Connected Fabric manager FM-0 Connected Configured Fabric control FC-0 Connected Configured FC-1 Connected Configured Diagnostic routing engine DRE-0 Connected Configured
Verifying a Network Node Group Nonstop Software Upgrade
Purpose
During the network Node group portion of a nonstop software upgrade, you should expect to see the backup network Node group Routing Engine upgrade first, followed by the Node devices within the network Node group upgrading one at a time, and ending with the upgrade of the master network Node group Routing Engine.
![]() | Note: If you configure an upgrade group for Node groups containing 2 or more Node devices, all Node devices within the upgrade group reboot at the same time. |
Action
- In an SSH session to the QFabric CLI, issue the request
for the network Node group nonstop software upgrade.
root@qfabric> request system software nonstop-upgrade node-group NW-NG-0 jinstall-qfabric-12.2X50-D10.3.rpmUpgrading target(s): NW-NG-0 [NW-NG-0 2012-06-01 09:45:06]: Starting with package ftp://169.254.0.3/pub/images/12.2X50-D10.3/jinstall-qfx.tgz [NW-NG-0 2012-06-01 09:45:06]: Retrieving package [NW-NG-0 2012-06-01 09:46:18]: Pushing bundle to fpc0 [NW-NG-0 2012-06-01 09:46:52]: fpc0: Validate package... [NW-NG-0 2012-06-01 09:53:26]: ------- fpc0 ------- [NW-NG-0 2012-06-01 09:54:01]: Step 1 of 20 Creating temporary file system [NW-NG-0 2012-06-01 09:54:01]: Step 2 of 20 Determining installation source [NW-NG-0 2012-06-01 09:54:02]: Step 3 of 20 Processing format options [NW-NG-0 2012-06-01 09:54:02]: Step 4 of 20 Determining installation slice [NW-NG-0 2012-06-01 09:54:02]: Step 5 of 20 Creating and labeling new slices [NW-NG-0 2012-06-01 09:54:03]: Step 6 of 20 Create and mount new file system [NW-NG-0 2012-06-01 09:54:10]: Step 7 of 20 Getting OS bundles [NW-NG-0 2012-06-01 09:54:10]: Step 8 of 20 Updating recovery media [NW-NG-0 2012-06-01 09:54:31]: Step 9 of 20 Extracting incoming image [NW-NG-0 2012-06-01 09:55:43]: Step 10 of 20 Unpacking OS packages [NW-NG-0 2012-06-01 09:55:46]: Step 11 of 20 Mounting jbase package [NW-NG-0 2012-06-01 09:56:09]: Step 12 of 20 Creating base OS symbolic links [NW-NG-0 2012-06-01 09:57:05]: Step 13 of 20 Creating fstab [NW-NG-0 2012-06-01 09:57:05]: Step 14 of 20 Creating new system files [NW-NG-0 2012-06-01 09:57:05]: Step 15 of 20 Adding jbundle package [NW-NG-0 2012-06-01 09:59:30]: Step 16 of 20 Backing up system data [NW-NG-0 2012-06-01 09:59:44]: Step 17 of 20 Setting up shared partition data [NW-NG-0 2012-06-01 09:59:44]: Step 18 of 20 Checking package sanity in installation [NW-NG-0 2012-06-01 09:59:44]: Step 19 of 20 Unmounting and cleaning up temporary file systems [NW-NG-0 2012-06-01 09:59:47]: Step 20 of 20 Setting da0s1 as new active partition [NW-NG-0 2012-06-01 09:59:55]: Starting with package ftp://169.254.0.3/pub/images/12.2X50-D10.3/jinstall-dc-re.tgz [NW-NG-0 2012-06-01 09:59:55]: Retrieving package [NW-NG-0 2012-06-01 10:01:04]: Pushing bundle to re1 [NW-NG-0 2012-06-01 10:01:35]: re1: Validate package... [NW-NG-0 2012-06-01 10:02:56]: re0: Validate package... [NW-NG-0 2012-06-01 10:04:45]: Rebooting Backup RE [NW-NG-0 2012-06-01 10:08:31]: Initiating Chassis In-Service-Upgrade [NW-NG-0 2012-06-01 10:08:52]: Upgrading group: 0 fpc: 0 [NW-NG-0 2012-06-01 10:18:33]: Upgrade complete for group:0 [NW-NG-0 2012-06-01 10:18:33]: Finished processing all upgrade groups, last group :0 [NW-NG-0 2012-06-01 10:18:37]: Preparing for Switchover [NW-NG-0 2012-06-01 10:18:55]: Switchover Completed [Status 2012-06-01 10:18:58]: Upgrade completed with 0 errors Success
- Verify the progress of the upgrade by issuing the show chassis nonstop-upgrade node-group, show fabric administration inventory, show fabric administration inventory infrastructure, and show fabric administration inventory node-groups NW-NG-0 commands. You should see the backup network Node group Routing Engine reboot first, followed by each Node device within the network Node group, and ending with the reboot of master network Node group Routing Engine. Restarting devices appear as Disconnected in the output of the show fabric administration inventory command and restarting Routing Engines do not appear in output of the show fabric administration inventory infrastructure command until they return to service.
Related Documentation
- QFX Series
- Performing a Nonstop Software Upgrade on the QFabric System
- Understanding Nonstop Software Upgrade for QFabric Systems
- show chassis nonstop-upgrade node-group
- show fabric administration inventory
- show fabric administration inventory director-group status
- show fabric administration inventory infrastructure
- show fabric administration inventory interconnect-devices
- show fabric administration inventory node-groups