Navigation
Table of Contents
Guide That Contains This Content
[+] Expand All
[-] Collapse All
Related Documentation
- J Series
- Example: Setting the Chassis Cluster Node ID and Cluster ID
- Example: Configuring the Chassis Cluster Management Interface
- Example: Configuring the Number of Redundant Ethernet Interfaces in a Chassis Cluster
- Verifying a Chassis Cluster Configuration
- Verifying Chassis Cluster Statistics
- Clearing Chassis Cluster Failover Status
- SRX Series
- Example: Setting the Chassis Cluster Node ID and Cluster ID
- Example: Configuring the Chassis Cluster Management Interface
- Example: Configuring the Number of Redundant Ethernet Interfaces in a Chassis Cluster
- Verifying a Chassis Cluster Configuration
- Verifying Chassis Cluster Statistics
- Clearing Chassis Cluster Failover Status
- Additional Information
- Junos OS Feature Support Reference for SRX Series and J Series Devices

Verifying Chassis Cluster Failover Status
Purpose
Display the failover status of a chassis cluster.
Action
From the CLI, enter the show chassis cluster status command:
{primary:node1}user@host> show chassis cluster statusCluster ID: 3
Node name Priority Status Preempt Manual failover
Redundancy-group: 0, Failover count: 1
node0 254 primary no no
node1 2 secondary no no
Redundancy-group: 1, Failover count: 1
node0 254 primary no no
node1 1 secondary no no
{primary:node1}user@host> show chassis cluster statusCluster ID: 15
Node Priority Status Preempt Manual failover
Redundancy group: 0 , Failover count: 5
node0 200 primary no no
node1 0 lost n/a n/a
Redundancy group: 1 , Failover count: 41
node0 101 primary no no
node1 0 lost n/a n/a{primary:node1}user@host> show chassis cluster statusCluster ID: 15
Node Priority Status Preempt Manual failover
Redundancy group: 0 , Failover count: 5
node0 200 primary no no
node1 0 unavailable n/a n/a
Redundancy group: 1 , Failover count: 41
node0 101 primary no no
node1 0 unavailable n/a n/a
Related Documentation
- J Series
- Example: Setting the Chassis Cluster Node ID and Cluster ID
- Example: Configuring the Chassis Cluster Management Interface
- Example: Configuring the Number of Redundant Ethernet Interfaces in a Chassis Cluster
- Verifying a Chassis Cluster Configuration
- Verifying Chassis Cluster Statistics
- Clearing Chassis Cluster Failover Status
- SRX Series
- Example: Setting the Chassis Cluster Node ID and Cluster ID
- Example: Configuring the Chassis Cluster Management Interface
- Example: Configuring the Number of Redundant Ethernet Interfaces in a Chassis Cluster
- Verifying a Chassis Cluster Configuration
- Verifying Chassis Cluster Statistics
- Clearing Chassis Cluster Failover Status
- Additional Information
- Junos OS Feature Support Reference for SRX Series and J Series Devices