Help us improve your experience.

Let us know what you think.

Do you have time for a two-minute survey?

Navigation
Guide That Contains This Content
[+] Expand All
[-] Collapse All

    show uplink-failure-detection

    Syntax

    show uplink-failure-detection <group group-name>

    Release Information

    Command introduced in Junos OS Release 11.1 for EX Series switches.

    Description

    Display information about the uplink-failure-detection group, the member interfaces, and their status.

    Options

    none

    Display information about all groups configured for uplink failure detection.

    group group-name

    (Optional) Display information about the specified group only.

    Required Privilege Level

    view

    List of Sample Output

    show uplink-failure-detection

    Output Fields

    Table 1 lists the output fields for the show uplink-failure-detection command. Output fields are listed in the approximate order in which they appear.

    Field Name

    Field Description

    Group

    Name of the group.

    Uplink

    The uplink interface or interfaces configured as link-to-monitor.

    Note: The asterisk (*) indicates that the link is up.

    Downlink

    The downlink interface or interfaces configured as link-to-disable.

    Note: The asterisk (*) indicates that the link is up.

    Failure Action

    Status of uplink failure detection:

    • Active—The switch has detected an uplink failure and has brought the downlink down.
    • Inactive—The uplink or uplinks are up.

    Sample Output

    show uplink-failure-detection

    user@switch> show uplink-failure-detection
    Group             : group1
    Uplink            :  ge-0/0/0*
    Downlink          :  ge-0/0/1*
    Failure Action    :  Inactive
    
    Group             : group2
    Uplink            :  ge-0/0/3.0
    Downlink          :  ge-0/0/4.0
    Failure Action    :  Active
    

    Published: 2012-09-12