    jnxAlarmRelayMode

    The jnxAlarmRelayMode, whose object identifier is {jnxCraftAlarms 1}, denotes the alarm relay mode of the craft interface panel for the yellow and red alarms. This object uses the following integer values:

    • 1–Other: Other or unknown state
    • 2–passOn: Alarms are passed on. The alarm relay is activated to pass on the yellow or red alarms to audible sirens or visual flashing devices.
    • 3–cutOff: Alarms are turned off. Both the yellow and red alarms are cut off from the alarm relays and do not get passed on to audible sirens or visual flashing devices.

      Note: Both the yellow and red alarms can be cut off from the alarm relay using a Alarm Cutoff/Lamp Test button on the front panel of the router chassis.

     