    jnxBoxAnatomy

    The object identifier for the jnxMIBs root branch is {juniperMIB 3} and includes one main subbranch, jnxBoxAnatomy, whose object identifier is {jnxMibs 1}.

    The jnxBoxAnatomy MIB is explained in the following sections:

    Top-Level Objects

    The following branches of the jnxBoxAnatomy MIB are top-level objects:

    • jnxBoxClass—The object identifier for the jnxBoxClass object is {jnxBoxAnatomy 1}. This object classifies the chassis product line.
    • jnxBoxDescr—The object identifier for the jnxBoxDescr object is {jnxBoxAnatomy 2}. This object describes the chassis name and model.
    • jnxBoxSerialNo—The object identifier for the jnxBoxSerialNo object is {jnxBoxAnatomy 3}. This object indicates the serial number of the chassis. jnxBoxSerialNo remains blank if the serial number is unknown or unavailable.
    • jnxBoxRevision—The object identifier for the jnxBoxRevision object is {jnxBoxAnatomy 4}. This object indicates the last revision of the chassis.
    • jnxBoxInstalled—The object identifier for the jnxBoxInstalled object is {jnxBoxAnatomy 5}. This object indicates the last time the box was installed and operational, represented by the sysUpTime value.

    jnxContainersTable

    The object identifier for the jnxContainersTable object is {jnxBoxAnatomy 6}. This object shows the structure of the chassis.

    You can use the jnxContainersTable object to retrieve specific information about the router, such as how many of each component the router can contain. For example, the jnxContainersTable object of an M20 router indicates that the router can accommodate four Flexible PIC Concentrators (FPCs). However, it does not describe how many FPCs the router actually has.

    For more information about how many FPCs are actually on a router, see jnxContentsTable.

    Entries within the jnxContainersTable object are represented by the jnxContainersEntry object, whose object identifier is {jnxContainersTable 1}. The jnxContainersEntry object contains the following objects that describe the contents of a particular router:

    • jnxContainersIndex—The index value of an entry in the jnxContainersEntry object that corresponds to jnxContainersType and jnxContainersDescr, and whose object identifier is {jnxContainersEntry 1}.
    • jnxContainersView—The orientation of a container from the front of the router and whose object identifier is {jnxContainersEntry 2}. This object also indicates that the container is embedded in the router and how it is accessible from corresponding views. The value of this object is a bitmap represented as a sum. If multiple bits are set, you can access the container from that set of views. The values represent the bit positions and their corresponding views as follows:
      • 1—Front
      • 2—Rear
      • 4—Top
      • 8—Bottom
      • 16—Left side
      • 32—Right side

      For each view plane, if specified counters are scattered in various views, the numbering sequence starts from left to right and then from top to bottom, as follows:

      • Left side
      • Right side
      • Top
      • Bottom
      • Front
      • Rear

        Note: References to left and right sides are based on the view from the front of the chassis.

        In accordance with network management conventions, all indexes in the MIB begin with 1, not 0, although the slot number might be labeled 0.

    • jnxContainersLevel—The abstraction level of the box or components for the jnxContainersEntry object and whose object identifier is {jnxContainersEntry 3}. The level is enumerated from the outside to the inside, and from the outer layer to the inner layer.

      For example, if the top level (level 0) of the box refers to the chassis frame, then the next level (level 1) refers to the FPC slot within the chassis frame. Finally, the PIC space within the FPC slot of the chassis corresponds to level 2.

    • jnxContainersWithin—The container housing the entry at the next-higher level of the jnxContainersEntry object and whose object identifier is {jnxContainersEntry 4}.

      For example, the within value for jnxMediaCardSpacePIC.0 is 7. Because the jnxM20SlotFPC.0 retains an index value of 7, the FPC houses the PIC.

    • jnxContainersType—The component of the Chassis MIB at a specific index, view, level, and within value for the jnxContainersEntry object and whose object identifier is {jnxContainersEntry 5}.
    • jnxContainersDescr—The description of the component in the jnxContainersEntry object and whose object identifier is {jnxContainersEntry 6}.
    • jnxContainersCount—The maximum number of a given component that the router can accommodate within the jnxContainersEntry object and whose object identifier is {jnxContainersEntry 7}.

      For example, the M20 router can house a specific maximum number of FPCs within the chassis frame. The maximum number is not necessarily the actual number of FPCs; this can change dynamically.

    Table 1 through Table 8 provide examples of jnxContainersEntry objects in the jnxContainersTable. The following column headings for each table are abbreviated to correspond to the parts of the jnxContainersEntry objects:

    • Index—jnxContainersIndex
    • View—jnxContainersView
    • Level—jnxContainersLevel
    • Within—jnxContainersWithin
    • Type—jnxContainersType
    • Description—jnxContainersDescr
    • Count—jnxContainersCount

    Table 1 describes objects contained in a jnxContainersEntry in the jnxContainersTable of an M40 router.

    Table 1: jnxContainersEntry Objects in the jnxContainersTable of an M40 Router

    Index

    View

    Level

    Within

    Type

    Description

    Count

    1

    1

    0

    0

    jnxChassisM40.0

    Chassis frame compartment

    1

    2

    2

    1

    1

    jnxSlotPowerSupply.0

    Power supply compartment

    2

    3

    3

    1

    1

    jnxSlotCoolingImpeller.0

    Impeller compartment

    2

    4

    2

    1

    1

    jnxSlotCoolingFan.0

    Fan compartment

    3

    5

    2

    1

    1

    jnxSlotHostCtrl.0

    Host controller compartment

    1

    6

    1

    1

    1

    jnxSlotSCB.0

    SCB slot

    1

    7

    1

    1

    1

    jnxSlotFPC.0

    FPC slot

    8

    8

    1

    2

    7

    jnxMediaSlotCardPIC.0

    PIC space

    4

    9

    2

    1

    1

    jnxSlotRoutingEngine.0

    Routing Engine compartment

    1

    Table 2 describes objects in the jnxContainersTable of an M20 router.

    Table 2: jnxContainersEntry Objects in the jnxContainersTable of an M20 Router

    Index

    View

    Level

    Within

    Type

    Description

    Count

    1

    1

    0

    0

    jnxChassisM20.0

    Chassis frame compartment

    1

    2

    2

    1

    1

    jnxM20SlotPower.0

    Power supply compartment

    2

    4

    3

    1

    1

    jnxSlotFan.0

    Fan compartment

    4

    6

    2

    1

    1

    jnxM20SlotSSB.0

    SSB slot

    2

    7

    1

    1

    1

    jnxM20SlotFPC.0

    FPC slot

    4

    8

    1

    2

    7

    jnxM20MediaCardSpacePIC.0

    PIC space

    4

    9

    2

    1

    1

    jnxM20RE.0

    Routing Engine compartment

    2

    10

    1

    1

    1

    JNXM20FrontPanel.0

    Front display slot

    1

    Table 3 describes objects contained in a jnxContainersEntry in the jnxContainersTable of an M160 router.

    Table 3: jnxContainersEntry Objects in the jnxContainersTable of an M160 Router

    Index

    View

    Level

    Within

    Type

    Description

    Count

    1

    1

    0

    0

    jnxChassisM160.0

    Chassis frame compartment

    1

    2

    2

    1

    1

    Jnx160SlotPower.0

    Power supply compartment

    2

    4

    3

    1

    1

    jnxM160SlotFan.0

    Fan compartment

    4

    6

    2

    1

    1

    jnxM160SlotSFM.0

    SFM slot

    4

    7

    1

    1

    1

    jnxM160SlotFPC.0

    FPC slot

    8

    8

    1

    2

    7

    jnxM160MediaCardSlotPIC.0

    PIC space

    4

    9

    2

    1

    1

    jnxM160SlotHM.0

    Host slot

    2

    10

    1

    1

    1

    jnxM160SlotFPM.0

    FPM slot

    1

    11

    2

    1

    1

    jnxM160SlotPCG.0

    PCG slot

    2

    12

    2

    1

    1

    jnxM160SlotMCS.0

    MCS slot

    2

    13

    1

    1

    1

    jnxM160SlotCIP.0

    CIP slot

    1

    Table 4 describes objects contained in a jnxContainersEntry in the jnxContainersTable of an M10 router.

    Table 4: jnxContainersEntry Objects in the jnxContainersTable of an M10 Router

    Index

    View

    Level

    Within

    Type

    Description

    Count

    1

    1

    0

    0

    jnxChassisM10.0

    Chassis frame compartment

    1

    2

    2

    1

    1

    jnxM10SlotPower.0

    Power supply compartment

    2

    4

    2

    1

    1

    jnxM10SlotFan.0

    Fan compartment

    1

    6

    2

    1

    1

    jnxM10SlotFEB.0

    FEB slot

    1

    7

    1

    1

    1

    jnxM10SlotFPC.0

    FPC slot

    2

    8

    1

    2

    7

    jnxM10MediaCardSpacePIC.0

    PIC space

    4

    9

    2

    1

    1

    jnxM10SlotRE.0

    Routing Engine compartment

    1

    Table 5 describes objects contained in a jnxContainersEntry in the jnxContainersTable of an M5 router.

    Table 5: jnxContainersEntry Objects in the jnxContainersTable of an M5 Router

    Index

    View

    Level

    Within

    Type

    Description

    Count

    1

    1

    0

    0

    jnxChassisM5.0

    Chassis frame compartment

    1

    2

    2

    1

    1

    jnxM5SlotPower.0

    Power supply compartment

    2

    4

    3

    1

    1

    jnxM5SlotFan.0

    Fan compartment

    4

    6

    2

    1

    1

    jnxM5SlotFEB.0

    FEB slot

    1

    7

    1

    1

    1

    jnxM5SlotFPC.0

    FPC slot

    1

    8

    1

    2

    7

    jnxM5MediaCardSlotPIC.0

    PIC space

    4

    9

    2

    1

    1

    jnxM5SlotRE.0

    Routing Engine compartment

    1

    Table 6 describes objects contained in a jnxContainersEntry in the jnxContainersTable of a T640 router.

    Table 6: jnxContainersEntry Objects in the jnxContainersTable of a T640 Router

    Index

    View

    Level

    Within

    Type

    Description

    Count

    1

    1

    0

    0

    jnxChassisT640.0

    Chassis frame

    1

    2

    2

    1

    1

    jnxT640SlotPower.0

    PEM slot

    2

    4

    3

    1

    1

    jnxT640SlotFan.0

    Fan slot

    3

    7

    1

    1

    1

    jnxT640SlotFPC.0

    FPC slot

    8

    8

    1

    2

    7

    jnxT640MediaCardSpacePIC.0

    PIC slot

    4

    9

    2

    1

    1

    jnxT640SlotHM.0

    Host slot

    2

    10

    1

    1

    1

    jnxT640SlotFPB.0

    FPM slot

    1

    11

    2

    1

    1

    jnxT640SlotSCG.0

    SCG slot

    2

    12

    2

    1

    1

    jnxT640SlotCB.0

    CG slot

    2

    13

    1

    1

    1

    jnxT640SlotCIP.0

    CIP slot

    1

    14

    2

    1

    1

    jnxT640SlotSPMB.0

    SPMB slot

    2

    15

    2

    1

    1

    jnxT640SlotSIB.0

    SIB slot

    5

    Table 7 describes objects contained in a jnxContainersEntry in the jnxContainersTable of a T320 router.

    Table 7: jnxContainersEntry Objects in the jnxContainersTable of a T320 Router

    Index

    View

    Level

    Within

    Type

    Description

    Count

    1

    1

    0

    0

    jnxChassisT320.0

    Chassis frame

    1

    2

    2

    1

    1

    jnxT320SlotPower.0

    PEM slot

    2

    4

    3

    1

    1

    jnx320SlotFan.0

    Fan slot

    3

    7

    1

    1

    1

    jnxT320SlotFPC.0

    FPC slot

    8

    8

    1

    2

    7

    jnxT320MediaCardSpacePIC.0

    PIC slot

    2

    9

    2

    1

    1

    jnxT320SlotHM.0

    Host slot

    2

    10

    1

    1

    1

    jnxT320SlotFPB.0

    FPM slot

    1

    11

    2

    1

    1

    jnxT320SlotSCG.0

    SCG slot

    2

    12

    2

    1

    1

    jnxT320SlotCB.0

    CB slot

    2

    13

    1

    1

    1

    jnxT320SlotCIP.0

    CIP slot

    1

    14

    2

    1

    1

    jnxT320SlotSPMB.0

    SPMB slot

    2

    15

    2

    1

    1

    jnxT320SlotSIB.0

    SIB slot

    3

    Table 8 describes objects contained in a jnxContainersEntry in the jnxContainersTable of an M40e router.

    Table 8: jnxContainersEntry Objects in the jnxContainersTable of an M40e Router

    Index

    View

    Level

    Within

    Type

    Description

    Count

    1

    1

    0

    0

    jnxChassisM40e.0

    Chassis frame compartment

    1

    2

    2

    1

    1

    jnxM40eSlotPower.0

    Power supply compartment

    2

    4

    3

    1

    1

    jnxM40eSlotFan.0

    Fan compartment

    4

    6

    2

    1

    1

    jnxM40eSlotSFM.0

    SFM slot

    2

    7

    1

    1

    1

    jnxM40eSlotFPC.0

    FPC slot

    8

    8

    1

    2

    7

    jnxM40eMediaCardSpacePIC.0

    PIC space

    4

    9

    2

    1

    1

    jnxM40eSlotHM.0

    Host slot

    2

    10

    1

    1

    1

    jnxM40eSlotFPM.0

    FPM slot

    1

    11

    2

    1

    1

    jnxM40eSlotPCG.0

    PCG slot

    2

    12

    2

    1

    1

    jnxM40eSlotMCS.0

    MCS slot

    2

    13

    1

    1

    1

    jnxM40eSlotCIP.0

    CIP slot

    1

    Table 9 describes objects contained in a jnxContainersEntry in the jnxContainersTable of a T4000 router.

    Table 9: jnxContainersEntry Objects in the jnxContainersTable of a T4000 Router

    Index

    View

    Level

    Within

    Type

    Description

    Count

    1

    1

    0

    0

    jnxChassisT4000.0

    Chassis frame

    1

    2

    2

    1

    1

    jnxT4000SlotPower.0

    PEM slot

    2

    4

    3

    1

    1

    jnxT4000SlotFan.0

    Fan slot

    3

    7

    1

    1

    1

    jnxT4000SlotFPC.0

    FPC slot

    8

    8

    1

    2

    7

    jnxT4000MediaCardSpacePIC.0

    PIC slot

    4

    9

    2

    1

    1

    jnxT4000SlotHM.0

    RoutingEngine slot

    2

    10

    1

    1

    1

    jnxT4000SlotFPB.0

    FPM slot

    1

    11

    2

    1

    1

    jnxT4000SlotSCG.0

    SCG slot

    2

    12

    2

    1

    1

    jnxT4000SlotCB.0

    CG slot

    2

    13

    1

    1

    1

    jnxT4000SlotCIP.0

    CIP slot

    1

    14

    2

    1

    1

    jnxT4000SlotSPMB.0

    SPMB slot

    2

    15

    2

    1

    1

    jnxT4000SlotSIB.0

    SIB slot

    5

    19

    1

    1

    1

    jnxT4000SlotPSD.0

    PSD slot

    31

    jnxContentsLastChange

    The object identifier for jnxContentsLastChange object is {jnxBoxAnatomy 7}. This object indicates the time at which the box contents last changed, represented by the sysUpTime value.

    jnxContentsTable

    The object identifier for jnxContentsTable object is {jnxBoxAnatomy 8}. This object specifies the contents of the chassis.

    The jnxContentsTable lists the contents of an entry, which are defined as follows:

    • jnxContentsContainerIndex—Associates the jnxContainersIndex with the jnxContainersTable. The object identifier is {jnxContentsEntry 1}.
    • jnxContentsL1Index—Denotes the level-one index of the container housing the component. The object identifier is {jnxContentsEntry 2}. It indicates the position of the component within different levels of the containers. This value is 0 if the position is unavailable or not applicable.

      Note: MIBs start with a value of 1, whereas the physical count on the router starts with a value of 0. To find the actual location of a component within a router, you must subtract 1 from the L1, L2, or L3 index.

    • jnxContentsL2Index—Denotes the level-two index of the container housing the component. The object identifier is {jnxContentsEntry 3}. It indicates the position of the component within different levels of the containers. This value is 0 if the position is unavailable or not applicable.
    • jnxContentsL3Index—Denotes the level-three index of the container housing the component. The object identifier is {jnxContentsEntry 4}. It indicates the position of the component within different levels of the containers. This value is 0 if the position is unavailable or not applicable.
    • jnxContentsType—Indicates the type of the component at a specific container index or L1, L2, or L3 index. The object identifier is {jnxContentsEntry 5}.
    • jnxContentsDescr—Specifies the type of the component in plain English. The object identifier is {jnxContentsEntry 6}.
    • jnxContentsSerialNo—Specfies the serial number of the component. The object identifier is {jnxContentsEntry 7}.
    • jnxContentsRevision—Contains the revision level of the component. The object identifier is {jnxContentsEntry 8}.
    • jnxContentsInstalled—Indicates the time at which the component was last installed and operational, represented by the sysUpTime value. The object identifier is {jnxContentsEntry 9}.
    • jnxContentsPartNo—Contains the part number of the component (blank if unknown or unavailable). The object identifier is {jnxContentsEntry 10}.
    • jnxContentsChassisId —Contains the ID of the chassis that contains the components. The object identifier is {jnxContentsEntry 11}.
    • jnxContentsChassisDescr—Specifies the description of the chassis in plain English. The object identifier is {jnxContentsEntry 12}.
    • jnxContentsChassisCleiCode—Contains the CLEI code of the chassis that contains the components listed in the row. A CLEI code is an intelligent code that consists of 10 alphanumeric characters with 4 data elements. The first data element is considered the basic code, with the first two characters indicating the technology or equipment type, and the third and fourth characters denoting the functional subcategory. The second data element represents the features, and its three characters denote functional capabilities or changes. The third data element has one character and denotes a reference to a manufacturer, system ID, specification, or drawing. The fourth data element consists of two characters and contains complementary data. These two characters provide a means of differentiating or providing uniqueness between the eight character CLEI codes by identifying the manufacturing vintage of the product. For more information about CLEI code, see http://www.commonlanguage.com/resources/commonlang/ productshowroom/showroom/equip_id/carriers/overview.html . The object identifier is {jnxContentsEntry 13}.

    Table 10 through Table 12 provide examples of jnxContentEntry objects. The following column headings for each table are abbreviated to correspond to the parts of the jnxContentsEntry objects:

    • Container index— jnxContentsContainerIndex
    • L1 Index—jnxContentsL1Index
    • L2 Index—jnxContentsL2Index
    • L3 Index—jnxContentsL3Index
    • Type—jnxContentsType
    • Description—jnxContentsDescr
    • Serial Number—jnxContentsSerialNo
    • Revision—jnxContentsRevision
    • Installed—jnxContentsInstalled
    • Part Number—jnxContentsPartNo

    Table 10 provides an example of jnxContentEntry objects in the jnxContentTable of an M20 router.

    Table 10: jnxContentsEntry Objects in the jnxContentsTable of an M20 Router

    Container Index

    L1 Index

    L2 Index

    L3 Index

    Type

    Description

    Serial Number

    Revision

    Installed

    Part Number

    1

    1

    1

    0

    jnxBackplaneM20.0

    Midplane

    AL3280

    REV07

    0:0:00:00.00

    710-00157

    2

    1

    0

    0

    jnxM20PowerDC.0

    DC power supply A

    001652

    REV 05

    0:0:00:00.00

    740-00146

    2

    2

    0

    0

    jnxM20PowerDC.0

    DC power supply B

    001652

    REV 05

    0:0:00:00.00

    740-00146

    4

    1

    0

    0

    jnxM20Fan.0

    Front top fan

    0:0:00:00.00

    4

    2

    0

    0

    jnxM20Fan

    Middle fan

    0:0:00:00.00

    4

    3

    0

    0

    jnxM20Fan

    Bottom fan

    0:0:00:00.00

    4

    4

    4

    0

    jnxM20Fan

    Rear fan

    0:0:00:00.00

    6

    1

    0

    0

    jnxM20SSB.0

    SSB 0 Internet Processor II

    AG0809

    REV 01

    0:0:00:35.17

    710-001951

    7

    1

    0

    0

    jnxM20FPC.0

    FPC @ 0/*/*

    AN1335

    REV 01

    0:0:01:01.80

    710-001292

    7

    2

    0

    0

    jnxM20FPC.0

    FPC @ 1/*/*

    AN1124

    REV 01

    0:0:01:07:96

    710-001292

    7

    3

    0

    0

    jnxM20FPC.0

    FPC @ 2/*/*

    AN1726

    REV 01

    0:0:01:14:12

    710-001292

    7

    4

    0

    0

    jnxM20FPC.0

    FPC @ 3/*/*

    AN1691

    REV 01

    0:0:01:20.28

    710-001292

    8

    1

    1

    0

    jnxM20QuadEther.0

    PIC: 4x, F/E, 100BASE-TX @ 0/0/*

    HD4313

    REV 04

    0:0:00:00.00

    750-002992

    8

    1

    2

    0

    jnxM20QuadEther.0

    PIC: 4x, F/E, 100BASE-TX @ 0/1/*

    AJ5844

    REV 04

    0:0:00:00.00

    750-002992

    8

    1

    3

    0

    jnxM20QuadEther.0

    PIC: 4x, F/E, 100BASE-TX @ 0/2/*

    HD4518

    REV 04

    0:0:00:00.00

    750-002992

    8

    1

    4

    0

    jnxM20QuadEther.0

    PIC: 4x, F/E, 100BASE-TX @ 0/3/*

    HD4515

    REV 04

    0:0:00:00.00

    750-002992

    8

    2

    1

    0

    jnxM20QuadEther.0

    PIC: 4x, F/E, 100BASE-TX @ 1/0/*

    HD4296

    REV 04

    0:0:00:00.00

    750-002992

    8

    2

    2

    0

    jnxM20QuadEther.0

    PIC: 4x, F/E, 100BASE-TX @ 1/1/*

    HD4323

    REV 04

    0:0:00:00.00

    750-002992

    8

    2

    3

    0

    jnxM20QuadEther.0

    PIC: 4x, F/E, 100BASE-TX @ 1/2/*

    HD4129

    REV 04

    0:0:00:00.00

    750-002992

    8

    2

    4

    0

    jnxM20QuadEther.0

    PIC: 4x, F/E, 100BASE-TX @ 1/3/*

    HD4341

    REV 04

    0:0:00:00.00

    750-002992

    8

    3

    1

    0

    jnxM20QuadEther.0

    PIC: 4x, F/E, 100BASE-TX@ 2/0/*

    AH4147

    REV 07

    0:0:00:00.00

    750-002303

    8

    3

    2

    0

    jnxM20QuadEther.0

    PIC: 4x, F/E, 100BASE-TX @ 2/1/*

    AH4238

    REV 07

    0:0:00:00.00

    750-002303

    8

    3

    3

    0

    jnxM20QuadEther.0

    PIC: 4x, F/E, 100BASE-TX @ 2/2/*

    AH4116

    REV 07

    0:0:00:00.00

    750-002303

    8

    3

    4

    0

    jnxM20QuadEther.0

    PIC: 4x, F/E, 100BASE-TX @ 2/3/*

    AH4208

    REV 07

    0:0:00:00.00

    750-002303

    8

    4

    1

    0

    jnxM20GigEther.0

    PIC: 1x G/E, 1000BASE-SX @ 3/0/*

    AS3697

    REV 07

    0:0:00:00.00

    750-001072

    8

    4

    2

    0

    jnxM20ChOc12toDS3.0

    PIC: 1x COC12SMIR @ 3/1/*

    AE1110

    REV 08

    0:0:00:00.00

    750-001190

    8

    4

    4

    0

    jnxM20ChStml1.0

    PIC: 1x CSTM1SMIR @ 3/3/*

    AD9599

    REV 04

    0:0:00:00.00

    750-003250

    9

    1

    0

    0

    jnxM20RE.0

    Routing Engine

    3:16:16:53.21

    10

    1

    0

    0

    jnxM20FrontPanel.0

    Front panel display

    0:0:00:00.00

    To verify the L1, L2, and L3 indexes, use the show chassis hardware command. Sample command output from an M20 router is as follows:

    user@host> show chassis hardware
    Item    Version  Part number   Serial Number    Description
    Chassis53711     M20
    Backplane        REV 07   710-001517       AL3280
    Power Supply A   REV 05   740-001466          001652      DC
    Power Supply B   REV 05   740-001466          001632      DC
    Display         REV 04   710-001519      AP9225
    Host 0 c900000619e6ba01 teknor
    SSB slot 0        REV 01  710-001951        AG0809      Internet Processor
    II
    FPC 0      REV 01  710-001292  AN1335
     PIC 0     REV 04  750-002992  HD4313      4x F/E, 100 BASE-TX
     PIC 1     REV 04  750-002992  AJ5844      4x F/E, 100 BASE-TX
     PIC 2     REV 04  750-002992  HD4518      4x F/E, 100 BASE-TX
     PIC 3     REV 04  750-002992  HD4515      4x F/E, 100 BASE-TX
    FPC 1      REV 01  710-001292  AN1124
     PIC 0     REV 04  750-002992  HD4296      4x F/E, 100 BASE-TX
     PIC 1     REV 04  750-002992  HD4323      4x F/E, 100 BASE-TX
     PIC 2     REV 04  750-002992  HD4129      4x F/E, 100 BASE-TX
     PIC 3     REV 04  750-002992  HD4341      4x F/E, 100 BASE-TX
    FPC 2      REV 01  710-001292  AN1726
     PIC 0     REV 07  750-002303  AH4147      4x F/E, 100 BASE-TX
     PIC 1     REV 07  750-002303  AH4238      4x F/E, 100 BASE-TX
     PIC 2     REV 07  750-002303  AH4116      4x F/E, 100 BASE-TX
     PIC 3     REV 07  750-002303  AH4208      4x F/E, 100 BASE-TX
    FPC 3      REV 01  710-001292  AN1691
     PIC 0     REV 08  750-001072  AS3697      1x G/E, 1000
    BASE-SX
     PIC 1     REV 03  750-001190  AE1110      1x COC12, SMIR
     PIC 3     REV 04  750-003250  AD9599      1x CSTM1, SMIR
    

    Table 11 provides an example of jnxContentEntry objects in the jnxContentTable of a T640 router.

    Table 11: jnxContentsEntry Objects in the jnxContentsTable of a T640 Router

    Container Index

    L1 Index

    L2 Index

    L3 Index

    Type

    Description

    Serial Number

    Revision

    Installed

    Part Number

    1

    1

    0

    0

    jnxMidplaneT640.0

    Midplane

    AX5633

    REV 04

    0:0:00:00.00

    710-002726

    2

    2

    0

    0

    jnxT640Power.0

    PEM 1

    MD21815

    RevX02

    0:0:00:00.00

    740-002595

    4

    1

    1

    0

    jnxT640Fan.0

    Top left front fan

    0:0:00:00.00

    4

    1

    2

    0

    jnxT640Fan.0

    Top left middle fan

    0:0:00:00.00

    4

    1

    3

    0

    jnxT640Fan.0

    Top left rear fan

    0:0:00:00.00

    4

    1

    4

    0

    jnxT640Fan.0

    Top right front fan

    0:0:00:00.00

    4

    1

    5

    0

    jnxT640Fan.0

    Top right middle fan

    0:0:00:00.00

    4

    1

    6

    0

    jnxT640Fan.0

    Top right rear fan

    0:0:00:00.00

    4

    2

    1

    0

    jnxT640Fan.0

    Bottom left front fan

    0:0:00:00.00

    4

    2

    2

    0

    jnxT640Fan.0

    Bottom left middle fan

    0:0:00:00.00

    4

    2

    3

    0

    jnxT640Fan.0

    Bottom left rear fan

    0:0:00:00.00

    4

    2

    4

    0

    jnxT640Fan.0

    Bottom right front fan

    0:0:00:00.00

    4

    2

    5

    0

    jnxT640Fan.0

    Bottom right middle fan

    0:0:00:00.00

    4

    2

    6

    0

    jnxT640Fan.0

    Bottom right rear fan

    0:0:00:00.00

    4

    3

    1

    0

    jnxT640Fan.0

    Fourth blower from top

    0:0:00:00.00

    4

    3

    2

    0

    jnxT640Fan.0

    Bottom blower

    0:0:00:00.00

    4

    3

    3

    0

    jnxT640Fan.0

    Middle blower

    0:0:00:00.00

    4

    3

    4

    0

    jnxT640Fan.0

    Top blower

    0:0:00:00.00

    4

    3

    5

    0

    jnxT640Fan.0

    Second blower from top

    0:0:00:00.00

    7

    2

    0

    0

    jnxT640FPC.0

    FPC @ 1/*/*

    HE3009

    REV 01

    0:18:56:48.81

    710-002385

    7

    2

    1

    0

    jnxT640FPC.0

    FPC @ 1/0/* top temperature sensor

    HE3009

    REV 01

    0:18:56:48.81

    710-002385

    7

    2

    2

    0

    jnxT640FPC.0

    FPC @ 1/1/* bottom temperature sensor

    HE3009

    REV 01

    0:18:56:48.81

    710-002385

    7

    6

    0

    0

    jnxT640FPC.0

    FPC @ 5/*/*

    HD5001

    REV 03

    0:18:57:02.71

    710-001721

    7

    6

    1

    0

    jnxT640FPC.0

    FPC @ 5/0/* top temperature sensor

    HD5001

    REV 03

    0:18:57:02.71

    710-001721

    7

    6

    2

    0

    jnxT640FPC.0

    FPC @ 5/1/* bottom temperature sensor

    HD5001

    REV 03

    0:18:57:02.71

    710-001721

    7

    8

    0

    0

    jnxT640FPC.0

    FPC @ 7/*/*

    HE3179

    REV 01

    0:18:56:52.85

    710-002385

    7

    8

    1

    0

    jnxT640FPC.0

    FPC @ 7/0/* top temperature sensor

    HE3179

    REV 01

    0:18:56:52.85

    710-002385

    7

    8

    2

    0

    jnxT640FPC.0

    FPC @ 7/1/* bottom temperature sensor

    HE3179

    REV 01

    0:18:56:52.85

    710-002385

    8

    2

    1

    0

    jnxT640PIC3.0

    PIC: 1x G/E, 1000BASE-SX @ 1/0/*

    AP5542

    REV 08

    0:18:56:50.91

    750-001072

    8

    2

    2

    0

    jnxT640PIC3.0

    PIC: 1x OC-12 ATM, SMIR @ 1/1/*

    AK6894

    REV 02

    0:18:56:55.24

    750-002983

    8

    2

    3

    0

    jnxT640PIC3.0

    PIC: 1x G/E, 1000 BASE-SX @ 1/2/*

    HD4968

    REV 04

    0:18:56:55.64

    750-001894

    8

    6

    1

    0

    jnxT640PIC3.0

    PIC: 1x OC-192 SM SR1 @ 5/0/*

    HC0273

    REV 01

    0:18:57:04.47

    750-004535

    8

    6

    2

    0

    jnxT640PIC3.0

    PIC: 1x OC-192 SM SR1 @ 5/1/*

    HC0271

    REV 01

    0:18:57:04.55

    750-004535

    8

    6

    3

    0

    jnxT640PIC3.0

    PIC: 1x OC-192 SM SR1 @ 5/2/*

    HC0254

    REV 01

    0:18:57:04.64

    750-004535

    8

    8

    1

    0

    jnxT640PIC3.0

    PIC: 2x G/E, 1000Base-SX @ 7/0/*

    AD3632

    REV 01

    0:18:56:55.16

    710-002381

    8

    8

    2

    0

    jnxT640PIC3.0

    PIC: 4x OC-12 SONET, SMIR @ 7/1/*

    AD3831

    REV 05

    0:18:56:55.18

    750-001901

    8

    8

    3

    0

    jnxT640PIC3.0

    PIC: 1x OC-48 SONET, SMIR @ 7/2/*

    AA9603

    REV 01

    0:18:56:55.21

    750-001900

    8

    8

    4

    0

    jnxT640PIC3.0

    PIC: 1x OC-48 SONET, SMSR @ 7/3/*

    AD5724

    REV 05

    0:18:56:55.24

    750-001900

    9

    1

    0

    0

    jnxT640HM.0

    Host 0

    0:19:19:30.95

    9

    2

    0

    0

    jnxT640HM.0

    Host 1

    2108 6570 0292

    REV 01

    2:19:45:51.00

    740-005022

    10

    1

    0

    0

    jnxT640FPB.0

    FPM

    HE3245

    REV 02

    0:0:00:00.00

    710-002901

    11

    1

    0

    0

    jnxT640SCG.0

    SCG 0

    HF6023

    REV 04

    0:0:00:00.00

    710-003423

    11

    2

    0

    0

    jnxT640SCG.0

    SCG 1

    HF6061

    REV 04

    0:0:00:00.00

    710-003423

    12

    2

    0

    0

    jnxT640CB.0

    CB 0

    HE3614

    REV 06

    0:0:00:00.00

    710-002728

    12

    2

    0

    0

    jnxT640CB.0

    CB 1

    HE3627

    REV 06

    0:0:00:00.00

    710-002728

    13

    1

    0

    0

    jnxT640CIP.0

    CIP

    HA4729

    REV 05

    0:0:00:00.00

    710-002895

    14

    1

    0

    0

    jnxT640SPMB.0

    SPMB 0

    HF6876

    REV 02

    0:18:56:06.72

    710-003229

    14

    2

    0

    0

    jnxT640SPMB.0

    SPMB 1

    HG6237

    REV 02

    0:18:56:08.01

    710-003229

    15

    1

    0

    0

    jnxT640SIB.0

    SIB 0

    HJ9669

    REV 02

    0:0:00:00.00

    710-005157

    15

    2

    0

    0

    jnxT640SIB.0

    SIB 1

    HJ9668

    REV 02

    0:0:00:00.00

    710-005157

    15

    3

    0

    0

    jnxT640SIB.0

    SIB 2

    HH3039

    REV 02

    0:0:00:00.00

    710-005157

    15

    4

    0

    0

    jnxT640SIB.0

    SIB 3

    HH3041

    REV 02

    0:0:00:00.00

    710-005157

    15

    5

    0

    0

    jnxT640SIB.0

    SIB 4

    HJ9657

    REV 02

    0:0:00:00.00

    710-005157

    To verify the L1, L2, and L3 indexes, use the show chassis hardware command. Sample command output from a T640 router is as follows:

    user@host> show chassis hardware
    Hardware inventory:
    Item       Version Part number Serial number   Description
    Chassis    T640
    Midplane    REV 04  710-002726  AX5633
    FPM GBUS    REV 02  710-002901  HE3245
    FPM Display    REV 02  710-002897  HA4873
    CIP          REV 05  710-002895  HA4729
    PEM 1         RevX02  740-002595  MD21815         Power Entry Module
    SCG 0         REV 04  710-003423  HF6023
    SCG 1         REV 04  710-003423  HF6061
    Host 0    unknown
    Host 1    REV 01  740-005022  210865700292   RE-3.0
    CB 0          REV 06  710-002728  HE3614
    CB 1          REV 06  710-002728  HE3627
    FPC 1         REV 01  710-002385  HE3009      FPC Type 1
     CPU          REV 06  710-001726  HC0010
     PIC 0        REV 08  750-001072  AP5542      1x G/E, 1000Base-SX
     PIC 1        REV 02  750-002983  AK6894      1x OC-12 ATM, SMIR
     PIC 2        REV 04  750-001894  HD4968      1x G/E, 1000Base-SX
     MMB 1        REV 03  710-001723  HE7264      MMB-144mbit
     ICBM         REV 01  710-003384  HE3042
     PPB 0        REV 01  710-003758  HE7173      PPB Type 2
     PPB 1        REV 01  710-003758  HE7170      PPB Type 2
    FPC 5         REV 03  710-001721  HD5001      FPC Type 3
     CPU         REV 06  710-001726          HA5080
     PIC 0        REV 01  750-004535  HC0273      1x OC-192 SM SR1
     PIC 1        REV 01  750-004535  HC0271      1x OC-192 SM SR1
     PIC 2        REV 01  750-004535  HC0254      1x OC-192 SM SR1
     MMB 0        REV 03  710-001723  HE7263      MMB-144mbit
     MMB 1        REV 03  710-001723  HE7266      MMB-144mbit
     ICBM         REV 01  710-003384  HE3044
     PPB 0        REV 02  710-002845  HD6027      PPB Type 3
     PPB 1        REV 02  710-002845  HD6039      PPB Type 3
    FPC 7         REV 01  710-002385  HE3179      FPC Type 2
     CPU         REV 06  710-001726          HE7915
     PIC 0        REV 01  710-002381  AD3632      2x G/E, 1000 BASE-SX
     PIC 1        REV 05  750-001901  AD3831      4x OC-12 SONET, SMIR
     PIC 2        REV 01  750-001900  AA9603      1x OC-48 SONET, SMIR
     PIC 3        REV 05  750-001900  AD5724      1x OC-48 SONET, SMSR
     MMB 1        REV 02  710-004047  HE3424      MMB-288mbit
     ICBM         REV 04  710-003384  HA4480
     PPB 0        REV 02  710-003758  HE3169      PPB Type 2
     PPB 1        REV 02  710-003758  HA4535      PPB Type 2
    SPMB 0       REV 02  710-003229 HF6876
    SPMB 1       REV 02  710-003229 HG6237
    SIB 0         REV 02  710-005157  HJ9669      SIB-I8-F16
    SIB 1         REV 02  710-005157  HJ9668      SIB-I8-F16
    SIB 2         REV 02  710-005157  HH3039      SIB-I8-F16
    SIB 3         REV 02  710-005157  HH3041      SIB-I8-F16
    SIB 4         REV 02  710-005157  HJ9657      SIB-I8-F16
    

    Table 12 provides an example of jnxContentEntry objects in the jnxContentTable of a T320 router.

    Table 12: jnxContentsEntry Objects in the jnxContentsTable of a T320 Router

    Container Index

    L1 Index

    L2 Index

    L3 Index

    Type

    Description

    Serial Number

    Revision

    Installed

    Part Number

    1

    1

    0

    0

    jnxMidplaneT320.0

    Midplane

    AY4527

    Rev 01

    (0) 0:00:00.00

    710-004339

    2

    1

    0

    0

    jnxT320Power.0

    PEM 0

    ML14099

    Rev 01

    (0) 0:00:00.00

    4

    1

    1

    0

    jnxT320Fan.0

    Top left front fan

    (0) 0:00:00.00

    4

    1

    2

    0

    jnxT320Fan.0

    Top left middle fan

    (0) 0:00:00.00

    4

    1

    3

    0

    jnxT320Fan.0

    Top left rear fan

    (0) 0:00:00.00

    4

    1

    4

    0

    jnxT320Fan.0

    Top right front fan

    (0) 0:00:00.00

    4

    1

    5

    0

    jnxT320Fan.0

    Top right middle fan

    (0) 0:00:00.00

    4

    1

    6

    0

    jnxT320Fan.0

    Top right rear fan

    (0) 0:00:00.00

    4

    2

    1

    0

    jnxT320Fan.0

    Bottom left front fan

    (0) 0:00:00.00

    4

    2

    2

    0

    jnxT320Fan.0

    Bottom left middle fan

    (0) 0:00:00.00

    4

    2

    3

    0

    jnxT320Fan.0

    Bottom left rear fan

    (0) 0:00:00.00

    4

    2

    4

    0

    jnxT320Fan.0

    Bottom right front fan

    (0) 0:00:00.00

    4

    2

    5

    0

    jnxT320Fan.0

    Bottom right middle fan

    (0) 0:00:00.00

    4

    2

    6

    0

    jnxT320Fan.0

    Bottom right rear fan

    (0) 0:00:00.00

    4

    3

    1

    0

    jnxT320Fan.0

    Rear tray top fan

    (0) 0:00:00.00

    4

    3

    2

    0

    jnxT320Fan.0

    Rear tray second fan

    (0) 0:00:00.00

    4

    3

    3

    0

    jnxT320Fan.0

    Rear tray middle fan

    (0) 0:00:00.00

    4

    3

    4

    0

    jnxT320Fan.0

    Rear tray fourth fan

    (0) 0:00:00.00

    4

    3

    5

    0

    jnxT320Fan.0

    Rear tray bottom fan

    (0) 0:00:00.00

    7

    4

    0

    0

    jnxT320FPC.0

    FPC @ 3/*/*

    AY4706

    REV 01

    (26190949) 3 days, 0:45:09.49

    710-004333

    7

    4

    1

    0

    jnxT320FPC.0

    FPC @ 3/0/* top temperature sensor

    AY4706

    REV 01

    (26190949) 3 days, 0:45:09.49

    710-004333

    7

    4

    2

    0

    jnxT320FPC.0

    FPC @ 3/1/* bottom temperature sensor

    AY4706

    REV 01

    (26190949) 3 days, 0:45:09.49

    710-004333

    8

    1

    1

    0

    jnxT320PIC3

    PIC: 1x OC-192 SM SR2 @ 0/0/*

    HJ9283

    REV 06

    (6378) 0:01:03.78

    750-004535

    8

    1

     

    2

    0

    jnxT320PIC3

    PIC: 1x OC-192 SM SR2 @ 0/1/*

    HJ9298

    REV 06

    (6434) 0:01:04.34

    750-004535

     

    9

    1

    0

    0

    jnxT320HM.0

    Host 0

    2108 6570 0286

    REV 01

    (32762924) 3 days, 19:00:29.24

    740-005022

    9

    2

    0

    0

    jnxT320HM.0

    Host 1

    2109 2900 0186

    REV 01

    (110269900) 12 days, 18:18:19.00

    740-005022

    10

    1

    0

    0

    jnxT320FPB.0

    FPM

    AY4514

    REV 02

    (0) 0:00:00.00

    710-004461

    11

    1

    0

    0

    jnxT320SCG.0

    SCG 0

    AY4520

    REV 06

    (0) 0:00:00.00

    710-004455

    11

    2

    0

    0

    jnxT320SCG.0

    SCG 1

    AY4526

    REV 06

    (0) 0:00:00.00

    710-004455

    12

    1

    0

    0

    jnxT320CB.0

    CB 0

    AY4765

    REV 11

    (0) 0:00:00.00

    710-002728

    12

    2

    0

    0

    jnxT320CB.0

    CB 1

    HG6051

    REV 06

    (0) 0:00:00.00

    710-002728

    13

    1

    0

    0

    jnxT320CIP.0

    CIP

    HC0476

    REV 05

    (0) 0:00:00.00

    710-002895

    14

    1

    0

    0

    jnxT320SPMB.0

    SPMB 0

    HB1893

    REV 02

    (26186997) 3 days, 0:44:29.97

    710-003229

    14

    2

    0

    0

    jnxT320SPMB.0

    SPMB 1

    HD5520

    REV 02

    (26186913) 3 days, 0:44:29.13

    710-003229

    15

    1

    0

    0

    jnxT320SIB.0

    SIB 0

    BC1509

    REV 02

    (0) 0:00:00.00

    710-005157

    15

    2

    0

    0

    jnxT320SIB.0

    SIB 1

    BC1512

    REV 02

    (0) 0:00:00.00

    710-005157

    15

    3

    0

    0

    jnxT320SIB.0

    SIB 2

    BC1494

    REV 02

    (0) 0:00:00.00

    710-005157

    To verify the L1, L2, and L3 indexes, use the show chassis hardware command. Sample command output from a T320 router is as follows:

    user@host> show chassis hardware
    Hardware inventory:
    Item             Version  Part number  Serial number     Description
    Chassis  T320
    Midplane         REV 01   710-004339   AY4527
    FPM GBUS         REV 02   710-004461   AY4514
    FPM Display      REV 02   710-002897   HF6097
    CIP              REV 05   710-002895   HC0476
    PEM 0            Rev 01   740-004359   ML14099           Power Entry
    Module
    SCG 0            REV 06   710-004455   AY4520
    SCG 1            REV 06   710-004455   AY4526
    RE 0               REV 01   740-005022   210865700286      RE-3.0
    RE 1               REV 01   740-005022   210929000186      RE-3.0
    CB 0             REV 11   710-002728   AY4765
    CB 1             REV 06   710-002728   HG6051
    FPC 1            REV 01   710-004333   AY4507            FPC Type 3
      CPU            REV 06   710-001726   HA4719
      MMB 1          REV 03   710-004047   HD5738            MMB-288mbit
      PPB 0          REV 02   710-002845   HC0988            PPB Type 3
    FPC 3            REV 01   710-004333   AY4706            FPC Type 3
      CPU            REV 06   710-001726   HE7916
      MMB 1          REV 03   710-004047   HG6326            MMB-288mbit
      PPB 0          REV 02   710-002845   HC0958            PPB Type 3
    SPMB 0           REV 02   710-003229   HB1893
    SPMB 1           REV 02   710-003229   HD5520
    SIB 0            REV 02   710-005157   BC1509            SIB-I8-F16
    SIB 1            REV 02   710-005157   BC1512            SIB-I8-F16
    SIB 2            REV 02   710-005157   BC1494            SIB-I8-F16
    

    Table 13 provides an example of jnxContentstEntry objects in the jnxContentTable of a T4000 router.

    Table 13: jnxContentsEntry Objects in the jnxContentsTable of a T4000 Router

    Container Index

    L1 Index

    L2 Index

    L3 Index

    Type

    Description

    Serial Number

    Revision

    Installed

    Part Number

    1

    1

    0

    0

    jnxMidplaneT1600.0

    Midplane

    S/NRC8652

    REV 01

    0:0:00:00.00

    710-027486

    2

    1

    0

    0

    jnxPower.0

    PEM 0

    MD21815

    REV 01

    0:0:00:00.00

    40-026384

    4

    1

    0

    0

    jnxT4000Fan.0

    Front Top Fan Tray

    0:0:00:00.00

    4

    1

    1

    0

    jnxT4000Fan.0

    Top Left Front fan

    0:0:00:00.00

    4

    1

    2

    0

    jnxT4000Fan.0

    Top Left Middle fan

    0:0:00:00.00

    4

    1

    3

    0

    jnxT4000Fan.0

    Top Left Rear fan

    0:0:00:00.00

    4

    1

    4

    0

    jnxT4000Fan.0

    Top Right Front fan

    0:0:00:00.00

    4

    1

    5

    0

    jnxT4000Fan.0

    Top right Middle fan

    0:0:00:00.00

    4

    1

    6

    0

    jnxT4000Fan.0

    Top Right Rear Fan

    0:0:00:00.00

    4

    2

    0

    0

    jnxT4000Fan.0

    Front Bottom fanTray

    0:0:00:00.00

    4

    2

    1

    0

    jnxT4000Fan.0

    BottomLeft Front fan

    0:0:00:00.00

    4

    2

    2

    0

    jnxT4000Fan.0

    BottomLeft Middle Fan

    0:0:00:00.00

    4

    2

    3

    0

    jnxT4000Fan.0

    BottomLeft Rear fan

    0:0:00:00.00

    4

    2

    4

    0

    jnxT4000Fan.0

    Bottom Right Front Fan

    0:0:00:00.00

    4

    2

    5

    0

    jnxT4000Fan.0

    Bottom Right Middle Fan

    0:0:00:00.00

    4

    2

    6

    0

    jnxT4000Fan.0

    Bottom Right Rear Fan

    0:0:00:00.00

    4

    3

    0

    0

    jnxT4000Fan.0

    Rear fan Tray

    0:0:00:00.00

    4

    3

    1

    0

    jnxT4000Fan.0

    Rear Tray Top Fan

    0:0:00:00.00

    4

    3

    2

    0

    jnxT4000Fan.0

    Rear Tray Second Fan

    0:0:00:00.00

    4

    3

    3

    0

    jnxT4000Fan.0

    Rear Tray Third Fan

    0:0:00:00.00

    4

    3

    4

    0

    jnxT4000Fan.0

    Rear Tray Fourth Fan

    0:0:00:00.00

    4

    3

    5

    0

    jnxT4000Fan.0

    Rear Tray Fifth Fan

    0:0:00:00.00

    4

    3

    6

    0

    jnxT4000Fan.0

    Rear Tray Sixth Fan

    0:0:00:00.00

    4

    3

    7

    0

    jnxT4000Fan.0

    Rear Tray Seventh Fan

    0:0:00:00.00

    4

    3

    8

    0

    jnxT4000Fan.0

    Rear Tray Bottom Fan

    0:0:00:00.00

    7

    2

    0

    0

    jnxT4000FPC.0

    FPC Type 4-ES@ 1/*/*

    S/NBBAG9691

    REV 03

    0:18:57:02.71

    710-033871

    7

    2

    1

    0

    jnxT4000FPC.0

    FPC Type 4-ES@ 1/*/* top temperature sensor

    S/NBBAG9691

    REV 03

    0:18:57:02.71

    710-033871

    7

    2

    2

    0

    jnxT4000FPC.0

    FPC Type 4-ES@ 1/*/* bottom temperature sensor

    S/NBBAG9691

    REV 03

    0:18:57:02.71

    710-033871

    7

    3

    0

    0

    jnxT4000FPC.0

    FPC Type 5-3D@ 2/*/*

    S/NEG3636

    REV 07

    0:18:56:52.85

    750-010153

    7

    3

    1

    0

    jnxT4000FPC.0

    FPC Type 5-3D@ 2/*/*

    S/NEG3636

    REV 07

    0:18:56:52.85

    750-010153

    7

    3

    2

    0

    jnxT4000FPC.0

    FPC Type 5-3D@ 2/*/* exhaust

    S/NEG3636

    REV 07

    0:18:56:52.85

    750-010153

    7

    5

    0

    0

    jnxT4000FPC.0

    FPC Type 5-3D @ 4/*/*

    S/NEG3641

    REV 07

    0:18:56:52.85

    750-032819

    7

    5

    1

    0

    jnxT4000FPC.0

    FPC Type 5-3D @ 4/*/* intake

    S/NEG3641

    REV 07

    0:18:56:52.85

    750-032819

    7

    5

    2

    0

    jnxT4000FPC.0

    FPC Type 5-3D @ 4/*/* exhaust

    S/NEG3641

    REV 07

    0:18:56:52.85

    750-032819

    8

    3

    1

    0

    jnxT4000PIC3.0

    PIC: 12x10GE (LAN/WAN) SFPP @ 2/0/*

    S/NEE3734

    REV 02

    0:18:57:04.47

    50-034624

    8

    3

    2

    0

    jnxT4000PIC3.0

    PIC: 12x10GE (LAN/WAN) SFPP @ 2/1/*

    S/NEE3705

    REV 02

    0:18:57:04.55

    750-034624

    8

    5

    1

    0

    jnxT4000PIC3.0

    PIC: 12x10GE (LAN/WAN) SFPP @ 4/1/*

    S/NEE3708

    REV 02

    0:18:56:55.16

    750-034624

    9

    1

    2

    0

    jnxT4000HM.0

    Routing Engine 0

    P737F-002685

    REV 06

    0:19:19:30.95

    740-02694

    9

    2

    0

    0

    jnxT4000HM.0

    Routing Engine 1

    P737F-002553

    REV 06

    2:19:45:51.00

    740-026941

    10

    1

    1

    0

    jnxT4000FPB.0

    FPM GBUS

    S/NBBAF7038

    REV 13

    0:0:00:00.00

    710-002901

    10

    1

    2

    0

    jnxT4000FPB.0

    FPM Display

    S/NBBAF7038

    REV 13

    0:0:00:00.00

    710-021387

    11

    1

    0

    0

    jnxT4000SCG.0

    SCG 0

    S/NBBAE5661

    REV 18

    0:0:00:00.00

    710-003423

    11

    2

    0

    0

    jnxT4000SCG.0

    SCG 1

    S/NBBAE5661

    REV 18

    0:0:00:00.00

    710-003423

    12

    1

    0

    0

    jnxT4000CB.0

    CB 0

    S/NEF7357

    REV 09

    0:0:00:00.00

    710-022597

    12

    2

    0

    0

    jnxT4000CB.0

    CB 1

    S/NEF7368

    REV 09

    0:0:00:00.00

    710-022597

    13

    1

    0

    0

    jnxT4000CIP.0

    CIP

    S/NBBAE2106

    REV 06

    0:0:00:00.00

    710-002895

    14

    1

    0

    0

    jnxT4000SPMB.0

    SPMB 0

    S/NEF6110

    REV 05

    0:18:56:06.72

    710-023321

    14

    2

    0

    0

    jnxT4000SPMB.0

    SPMB 1

    S/NEF6100

    REV 05

    0:18:56:08.01

    710-023321

    15

    1

    0

    0

    jnxT4000SIB.0

    SIB 0

    S/NEE6281

    REV 02

    0:0:00:00.00

    710-023321

    15

    2

    0

    0

    jnxT4000SIB.0

    SIB 1

    S/NEG2262

    REV 07

    0:0:00:00.00

    711-036340

    15

    3

    0

    0

    jnxT4000SIB.0

    SIB 2

    S/NEF1308

    REV 02

    0:0:00:00.00

    711-036340

    15

    4

    0

    0

    jnxT4000SIB.0

    SIB 3

    S/NEF1317

    REV 02

    0:0:00:00.00

    711-036340

    15

    5

    0

    0

    jnxT4000SIB.0

    SIB 4

    S/NEG2301

    REV 07

    0:0:00:00.00

    711-036340

    To verify the L1, L2, and L3 indexes, use the show chassis hardware command. Sample command output from a T4000 router is as follows:

    user@host> show chassis hardware
    Hardware inventory:
    Item             Version  Part number  Serial number     Description
    Chassis                                JN1172F25AHA      T4000
    Midplane         REV 01   710-027486   RC8355            T-series Backplane
    FPM GBUS         REV 13   710-002901   BBAE0927          T640 FPM Board
    FPM Display      REV 01   710-021387   EF6764            T1600 FPM Display
    CIP              REV 06   710-002895   BBAD9210          T-series CIP
    PEM 0            REV 01   740-036442   VA00016           Power Entry Module 6x60
    SCG 0            REV 18   710-003423   BBAD7248          T640 Sonet Clock Gen.
    SCG 1            REV 18   710-003423   BBAE3874          T640 Sonet Clock Gen.
    Routing Engine 0 REV 05   740-026941   P737F-002248      RE-DUO-1800
    Routing Engine 1 REV 06   740-026941   P737F-002653      RE-DUO-1800
    CB 0             REV 09   710-022597   ED0295            LCC Control Board
    CB 1             REV 09   710-022597   EA6050            LCC Control Board
    FPC 0            REV 26   750-032819   EK1173            FPC Type 5-3D
      CPU            REV 12   711-030686   EJ8584            SNG PMB
      PIC 0          REV 07   750-034624   EF6837            12x10GE (LAN/WAN) SFPP
        Xcvr 0       REV 01   740-031980   123363A01145      SFP+-10G-SR
        Xcvr 1       REV 01   740-031980   123363A01147      SFP+-10G-SR
        Xcvr 2       REV 01   740-031980   AJJ01P3           SFP+-10G-SR
        Xcvr 3       REV 01   740-031980   B10M03256         SFP+-10G-SR
        Xcvr 4       REV 01   740-031980   AJJ01M2           SFP+-10G-SR
        Xcvr 5       REV 01   740-031980   123363A01137      SFP+-10G-SR
        Xcvr 6       REV 01   740-031980   AJJ01PN           SFP+-10G-SR
        Xcvr 7       REV 01   740-031980   AJJ01NW           SFP+-10G-SR
        Xcvr 8       REV 01   740-031980   123363A01139      SFP+-10G-SR
        Xcvr 9       REV 01   740-031980   AJJ01KE           SFP+-10G-SR
        Xcvr 10      REV 01   740-031980   123363A01336      SFP+-10G-SR
        Xcvr 11      REV 01   740-031980   B10M01325         SFP+-10G-SR
      PIC 1          REV 07   750-034624   EF6800            12x10GE (LAN/WAN) SFPP
        Xcvr 0       REV 01   740-031980   AJJ01SA           SFP+-10G-SR
        Xcvr 1       REV 01   740-031980   AJJ01QZ           SFP+-10G-SR
        Xcvr 2       REV 01   740-031980   AJH0217           SFP+-10G-SR
        Xcvr 3       REV 01   740-031980   AJJ01TE           SFP+-10G-SR
        Xcvr 4       REV 01   740-031980   AJJ01KV           SFP+-10G-SR
        Xcvr 5       REV 01   740-031980   AJJ01MU           SFP+-10G-SR
        Xcvr 6       REV 01   740-031980   AJJ01R0           SFP+-10G-SR
        Xcvr 7       REV 01   740-031980   AJJ01TC           SFP+-10G-SR
        Xcvr 8       REV 01   740-031980   AJJ0364           SFP+-10G-SR
        Xcvr 9       REV 01   740-031980   AJD0GV3           SFP+-10G-SR
        Xcvr 10      REV 01   740-031980   B10M03343         SFP+-10G-SR
        Xcvr 11      REV 01   740-031980   AJJ01QJ           SFP+-10G-SR
      LMB 0          REV 05   711-034381   EJ8490            Type-0 LMB
      LMB 1          REV 04   711-035774   EJ8517            Type-1 LMB
      LMB 2          REV 05   711-034381   EJ8489            Type-0 LMB
    FPC 3            REV 07   750-032819   EG3637            FPC Type 5-3D
      CPU            REV 09   711-030686   EG0150            SNG PMB
      PIC 0          REV 08   750-035293   EF3657            1x100GE
        Xcvr 0       REV 01   740-032210   C22CQNJ           CFP-100G-LR4
      PIC 1          REV 10   750-034624   BBAN4098          12x10GE (LAN/WAN) SFPP
        Xcvr 0       REV 01   740-031980   B11J04902         SFP+-10G-SR
        Xcvr 1       REV 01   740-031980   B11J04891         SFP+-10G-SR
        Xcvr 2       REV 01   740-031980   AJJ01MX           SFP+-10G-SR
        Xcvr 3       REV 01   740-031980   B11J04183         SFP+-10G-SR
        Xcvr 4       REV 01   740-031980   B11J04894         SFP+-10G-SR
        Xcvr 5       REV 01   740-031980   B11J04184         SFP+-10G-SR
        Xcvr 6       REV 01   740-031980   B11J04897         SFP+-10G-SR
        Xcvr 7       REV 01   740-031980   B11J04899         SFP+-10G-SR
        Xcvr 8       REV 01   740-031980   AJJ01TV           SFP+-10G-SR
        Xcvr 9       REV 01   740-031980   B11J04057         SFP+-10G-SR
        Xcvr 10      REV 01   740-031980   AJJ01M4           SFP+-10G-SR
        Xcvr 11      REV 01   740-031980   B11J04905         SFP+-10G-SR
      LMB 0          REV 04   711-034381   EG1524            Type-0 LMB
      LMB 1          REV 03   711-035774   EG0345            Type-1 LMB
      LMB 2          REV 04   711-034381   EG1522            Type-0 LMB
    FPC 5            REV 03   710-033871   BBAJ0768          FPC Type 4-ES
      CPU            REV 11   710-016744   BBAH9342          ST-PMB2
      PIC 0          REV 09   750-029262   EE6789            100GE
      PIC 1          REV 03   750-034781   EE6655            100GE CFP
        Xcvr 0       REV 01   740-032210   J11A22334         CFP-100G-LR4
      BRIDGE 0       REV 03   711-029995   EE6572            100GE Bridge Board
      MMB 0          REV 07   710-025563   BBAJ4657          ST-MMB2
      MMB 1          REV 07   710-025563   BBAJ3073          ST-MMB2
    FPC 6            REV 05   750-010153   EF4936            FPC Type 5-3D
      CPU            REV 06   711-030686   EF4189            SNG PMB
      PIC 0          REV 10   750-034624   BBAN4109          12x10GE (LAN/WAN) SFPP
        Xcvr 0       REV 01   740-031980   B11J04895         SFP+-10G-SR
        Xcvr 1       REV 01   740-031980   B11J04898         SFP+-10G-SR
        Xcvr 2       REV 01   740-031980   B11J04021         SFP+-10G-SR
        Xcvr 3       REV 01   740-031980   B11J04903         SFP+-10G-SR
        Xcvr 4       REV 01   740-031980   B11J04311         SFP+-10G-SR
        Xcvr 5       REV 01   740-031980   B11J04059         SFP+-10G-SR
        Xcvr 6       REV 01   740-031980   B11J04016         SFP+-10G-SR
        Xcvr 7       REV 01   740-031980   B11J04017         SFP+-10G-SR
        Xcvr 8       REV 01   740-031980   B11J04887         SFP+-10G-SR
        Xcvr 9       REV 01   740-031980   B11J04297         SFP+-10G-SR
        Xcvr 10      REV 01   740-031980   B11J04893         SFP+-10G-SR
        Xcvr 11      REV 01   740-031980   B11J04022         SFP+-10G-SR
      PIC 1          REV 02   750-034624   EE3711            12x10GE (LAN/WAN) SFPP
        Xcvr 0       REV 01   740-031980   AJH033X           SFP+-10G-SR
        Xcvr 1       REV 01   740-031980   AJJ01N0           SFP+-10G-SR
        Xcvr 2       REV 01   740-031980   AJJ01SV           SFP+-10G-SR
        Xcvr 3       REV 01   740-031980   AJJ032L           SFP+-10G-SR
        Xcvr 4       REV 01   740-031980   B10M01593         SFP+-10G-SR
        Xcvr 5       REV 01   740-031980   AJD0FF1           SFP+-10G-SR
        Xcvr 6       REV 01   740-031980   AJJ01NU           SFP+-10G-SR
        Xcvr 7       REV 01   740-031980   123363A01305      SFP+-10G-SR
        Xcvr 8       REV 01   740-031980   B10M00361         SFP+-10G-SR
        Xcvr 9       REV 01   740-031980   AJJ01M7           SFP+-10G-SR
        Xcvr 10      REV 01   740-031980   AJJ032X           SFP+-10G-SR
        Xcvr 11      REV 01   740-031980   AJJ01PG           SFP+-10G-SR
      LMB 0          REV 04   711-034381   EF3838            Type-0 LMB
      LMB 1          REV 03   711-035774   EF3821            Type-1 LMB
      LMB 2          REV 04   711-034381   EF3834            Type-0 LMB
    SPMB 0           REV 05   710-023321   ED1990            LCC Switch CPU
    SPMB 1           REV 05   710-023321   EA2768            LCC Switch CPU
    SIB 0            REV 02   711-036340   EF8802            SIB-HC-3D
    SIB 1            REV 07   711-036340   EG2286            SIB-HC-3D
    SIB 2            REV 07   711-036340   EG2252            SIB-HC-3D
    SIB 3            REV 02   711-036340   EF1358            SIB-HC-3D
    SIB 4            REV 02   711-036340   EF8806            SIB-HC-3D
    Fan Tray 0                                               Front Top Fan Tray
    Fan Tray 1                                               Front Bottom Fan Tray -- Rev 2
    Fan Tray 2                                               Rear Fan Tray -- Rev 3

    jnxLEDLastChange

    The object identifier for the jnxLEDLastChange object is {jnxBoxAnatomy 9}. This object indicates when the LED last changed state. Its value is 0 if the sysUpTime value is unknown or if it already existed when the agent was active.

    jnxLEDTable

    The object identifier for the jnxLEDTable object is {jnxBoxAnatomy 10}. This object indicates the LED status of the router and lists the contents of an entry. Entries in the jnxLEDTable are represented by the jnxLEDEntry object, whose object identifier is {jnxLEDTable 1}.

    The jnxLEDTable describes the components of the LED Box Indicators, whose elements are described as follows:

    • jnxLEDAssociateTable—The associate table to which the entry is related, whose object identifier is {jnxLEDEntry 1}.
    • jnxLEDAssociateIndex—The index of the subject in the associated table to which the entry is related, whose object identifier is {jnxLEDEntry 2}. The associate index is the index of the subject in the associated table, which returns you to the jnxContainersTable.
    • jnxLEDL1Index—The level-one index of the associate table to which an entry is related, whose object identifier is {jnxLEDEntry 3}. It indicates the position of the component within the different levels of the containers. This value is 0 if the position is unavailable or not applicable.

      Note: MIBs start with a value of 1, while the physical count on the router starts with a value of 0. To find the actual location of a component within a router, you must subtract 1 from the L1, L2, or L3 index.

    • jnxLEDL2Index—The level-two index of the associate table to which an entry is related, whose object identifier is {jnxLEDEntry 4}. It indicates the position of the component within the different levels of the containers. This value is 0 if the position is unavailable or not applicable.
    • jnxLEDL3Index—The level-three index of the associate table to which an entry is related, whose object identifier is {jnxLEDEntry 5}. It indicates the position of the component within the different levels of the containers. This value is 0 if the position is unavailable or not applicable.
    • jnxLEDOriginator—The chassis component that originated the update, whose object identifier is {jnxLEDEntry 6}.
    • jnxLEDDescr—The name or detailed description of the entry, whose object identifier is {jnxLEDEntry 7}.
    • jnxLEDState—The state of the LED indicator, whose object identifier is {jnxLEDEntry 8}. The state is represented by one of the following values:
      • Amber—Alarm, offline, not working
      • Blue—Online as the active primary
      • Green—Working normally online as a standby backup if there is an active primary
      • Other—Unknown or unavailable
      • Red—Alert, component failed
      • Yellow—Alarm, warning
    • jnxLEDStateOrdered—The state of the LED indicator, whose object identifier is {jnxLEDEntry 9}. jnxLEDStateOrdered provides the same information as jnxLEDState but lists the states in a different order. The states are defined as follows:
      • Blue—Online as the active primary
      • Green—Working normally online as a standby backup if there is an active primary
      • Amber—Alarm, offline, not working
      • Yellow—Alarm, warning
      • Red—Alert, component failed
      • Other—Unknown or unavailable

    Table 14 through Table 16 provide examples of jnxLEDEntry objects. The following column headings for each table are abbreviated to correspond to the parts of the jnxLEDEntry objects:

    • Associate table—jnxLEDAssociateTable
    • Associate index—jnxLEDAssociateIndex
    • L1 Index—jnxLEDL1Index
    • L2 Index—jnxLEDL2Index
    • L3 Index—jnxLEDL3Index
    • Originator—jnxLEDOriginator
    • Description—jnxLEDDescr
    • State—jnxLEDState

    Table 14 provides an example of jnxLEDEntry objects in the jnxLEDTable of an M20 router.

    Table 14: jnxLEDEntry Objects in the jnxLEDTable of an M20 Router

    Associate Table

    Associate Index

    L1 Index

    L2 Index

    L3 Index

    Originator

    Description

    State

    jnxContentsTable

    1

    1

    0

    0

    jnxChassisM20.0

    Chassis alarm LED

    Other

    jnxContentsTable

    6

    1

    0

    0

    jnxM20SSB.0

    SSB 1 LED

    Blue

    jnxContentsTable

    6

    2

    0

    0

    jnxM20SSB.0

    SSB 2 LED

    Green

    jnxContentsTable

    7

    1

    0

    0

    jnxM20FPC.0

    FPC 1 LED

    Amber

    jnxContentsTable

    7

    2

    0

    0

    jnxM20FPC.0

    FPC 2 LED

    Blue

    jnxContentsTable

    7

    3

    0

    0

    jnxM20FPC.0

    FPC 3 LED

    Blue

    jnxContentsTable

    7

    4

    0

    0

    jnxM20FPC.0

    FPC 4 LED

    Amber

    jnxContentsTable

    9

    1

    0

    0

    jnxM20RE.0

    Routing Engine 1 LED

    Blue

    jnxContentsTable

    9

    2

    0

    0

    jnxM20RE.0

    Routing Engine 2 LED

    Other

    Table 15 provides an example of jnxLEDEntry objects in the jnxLEDTable of a T640 router.

    Table 15: jnxLEDEntry Objects in the jnxLEDTable of a T640 Router

    Associate Table

    Associate Index

    L1 Index

    L2 Index

    L3 Index

    Originator

    Description

    State

    jnxContentsTable

    1

    1

    0

    0

    jnxChassisT640.0

    Chassis alarm LED

    Other

    jnxContentsTable

    7

    1

    0

    0

    jnxT640FPC.0

    FPC slot 0 LED

    Other

    jnxContentsTable

    7

    2

    0

    0

    jnxT640FPC.0

    FPC slot 1 LED

    Green

    jnxContentsTable

    7

    3

    0

    0

    jnxT640FPC.0

    FPC slot 2 LED

    Other

    jnxContentsTable

    7

    4

    0

    0

    jnxT640FPC.0

    FPC slot 3 LED

    Other

    jnxContentsTable

    7

    5

    0

    0

    jnxT640FPC.0

    FPC slot 4 LED

    Other

    jnxContentsTable

    7

    6

    0

    0

    jnxT640FPC.0

    FPC slot 5 LED

    Green

    jnxContentsTable

    7

    7

    0

    0

    jnxT640FPC.0

    FPC slot 6 LED

    Other

    jnxContentsTable

    7

    8

    0

    0

    jnxT640FPC.0

    FPC slot 7 LED

    Green

    jnxContentsTable

    9

    1

    0

    0

    jnxT640HM.0

    Host 0 LED

    Blue

    jnxContentsTable

    9

    2

    0

    0

    jnxT640HM.0

    Host 1 LED

    Green

    Table 16 provides an example of jnxLEDEntry objects in the jnxLEDTable of a T320 router.

    Table 16: jnxLEDEntry Objects in the jnxLEDTable of a T320 Router

    Associate Table

    Associate Index

    L1 Index

    L2 Index

    L3 Index

    Originator

    Description

    State

    jnxContentsTable(3)

    1

    1

    0

    0

    jnxChassisT320.0

    Chassis alarm LED

    Other

    jnxContentsTable(3)

    7

    1

    0

    0

    jnxT320FPC.0

    FPC slot 0 LED

    Other

    jnxContentsTable(3)

    7

    2

    0

    0

    jnxT320FPC.0

    FPC slot 1 LED

    Other

    jnxContentsTable(3)

    7

    3

    0

    0

    jnxT320FPC.0

    FPC slot 2 LED

    Other

    jnxContentsTable(3)

    7

    4

    0

    0

    jnxT320FPC.0

    FPC slot 3 LED

    Other

    jnxContentsTable(3)

    7

    5

    0

    0

    jnxT320FPC.0

    FPC slot 4 LED

    Other

    jnxContentsTable(3)

    7

    6

    0

    0

    jnxT320FPC.0

    FPC slot 5 LED

    Other

    jnxContentsTable(3)

    7

    7

    0

    0

    jnxT320FPC.0

    FPC slot 6 LED

    Other

    jnxContentsTable(3)

    7

    8

    0

    0

    jnxT320FPC.0

    FPC slot 7 LED

    Other

    jnxContentsTable(3)

    9

    1

    0

    0

    jnxT320HM.0

    Host 0 LED

    Blue

    jnxContentsTable(3)

    9

    2

    0

    0

    jnxT320HM.0

    Host 1 LED

    Green

    jnxFilledLastChange

    The object identifier for the jnxFilledLastChange object is {jnxBoxAnatomy 11}. This object indicates when the box filled status last changed. This variable is 0 if the sysUpTime value is unknown or it already existed when the agent was active.

    jnxFilledTable

    The object identifier for the jnxFilledTable object is {jnxBoxAnatomy 12}. This object indicates whether a specific container in the router is used (filled) or empty. This table is used for inventory and capacity planning.

    Entries in the jnxFilledTable are represented by the jnxFilledEntry object, whose object identifier is {jnxFilledTable 1}.

    The jnxFilledTable describes the status of specific containers whose component objects are described as follows:

    • jnxFilledContainerIndex—The associated jnxContainersIndex in the jnxContainersTable, whose object identifier is {jnxFilledEntry 1}.
    • jnxFilledL1Index—The level-one index of the container housing the entry, whose object identifier is {jnxFilledEntry 2}.
    • jnxFilledL2Index—The level-two index of the container housing the entry, whose object identifier is {jnxFilledEntry 3}.
    • jnxFilledL3Index—The level-three index of the container housing the entry, whose object identifier is {jnxFilledEntry 4}.
    • jnxFilledDescr—The entry’s name or detailed description of the entry, whose object identifier is {jnxFilledEntry 5}.
    • jnxFilledState—The entry’s state (filled or empty), whose object identifier is {jnxFilledEntry 6}.

    Table 17 through Table 19 provide examples of jnxFilledEntry objects in the jnxFilledTable. The following column headings for each table are abbreviated to correspond to the parts of the jnxFilledEntry objects:

    • Container index—jnxFilledContainerIndex
    • L1—jnxFilledL1Index
    • L2—jnxFilledL2Index
    • L3—jnxFilledL3Index
    • Description—jnxFilledDescr
    • State—jnxFilledState

    Table 17 provides an example of jnxFilledEntry objects in the jnxFilledTable of an M20 router.

    Table 17: jnxFilledEntry Objects in the jnxFilledTable of an M20 Router

    Container Index

    L1

    L2

    L3

    Description

    State

    1

    1

    0

    0

    Chassis frame compartment

    Filled

    1

    1

    1

    0

    Temperature sensor space 0

    Filled

    1

    1

    2

    0

    Temperature sensor space 1

    Filled

    2

    1

    0

    0

    Power supply compartment A

    Filled

    2

    2

    0

    0

    Power supply compartment B

    Empty

    3

    1

    0

    0

    Rear top impeller compartment

    Filled

    3

    2

    0

    0

    Front bottom impeller compartment

    Filled

    4

    1

    0

    0

    Rear left fan compartment

    Filled

    4

    2

    0

    0

    Right center fan compartment

    Filled

    4

    3

    0

    0

    Rear right fan compartment

    Filled

    5

    1

    0

    0

    Host controller compartment

    Filled

    6

    1

    0

    0

    SCB slot

    Filled

    7

    1

    0

    0

    FPC slot 0

    Empty

    7

    2

    0

    0

    FPC slot 1

    Empty

    7

    3

    0

    0

    FPC slot 2

    Filled

    7

    4

    0

    0

    FPC slot 3

    Filled

    7

    5

    0

    0

    FPC slot 4

    Empty

    7

    6

    0

    0

    FPC slot 5

    Filled

    7

    7

    0

    0

    FPC slot 6

    Empty

    7

    8

    0

    0

    FPC slot 7

    Empty

    8

    1

    1

    0

    PIC space @ 0/0/*

    Empty

    8

    1

    2

    0

    PIC space @ 0/1/*

    Empty

    8

    1

    3

    0

    PIC space @ 0/2/*

    Empty

    8

    1

    4

    0

    PIC space @ 0/3/*

    Empty

    8

    2

    1

    0

    PIC space @ 1/0/*

    Empty

    8

    2

    2

    0

    PIC space @ 1/1/*

    Empty

    8

    2

    3

    0

    PIC space @ 1/2/*

    Empty

    8

    2

    4

    0

    PIC space @ 1/3/*

    Empty

    8

    3

    1

    0

    PIC space @ 2/0/*

    Filled

    8

    3

    2

    0

    PIC space @ 2/1/*

    Filled

    8

    3

    3

    0

    PIC space @ 2/2/*

    Filled

    8

    3

    4

    0

    PIC space @ 2/3/*

    Filled

    8

    4

    1

    0

    PIC space @ 3/0/*

    Filled

    8

    4

    2

    0

    PIC space @ 3/1/*

    Filled

    8

    4

    3

    0

    PIC space @ 3/2/*

    Filled

    8

    4

    4

    0

    PIC space @ 3/3/*

    Filled

    8

    5

    1

    0

    PIC space @ 4/0/*

    Empty

    8

    5

    2

    0

    PIC space @ 4/1/*

    Empty

    8

    5

    3

    0

    PIC space @ 4/2/*

    Empty

    8

    5

    4

    0

    PIC space @ 4/3/*

    Empty

    8

    6

    1

    0

    PIC space @ 5/0/*

    Filled

    8

    6

    2

    0

    PIC space @ 5/1/*

    Filled

    8

    6

    3

    0

    PIC space @ 5/2/*

    Filled

    8

    6

    4

    0

    PIC space @ 5/3/*

    Filled

    8

    7

    1

    0

    PIC space @ 6/0/*

    Empty

    8

    7

    2

    0

    PIC space @ 6/1/*

    Empty

    8

    7

    3

    0

    PIC space @ 6/2/*

    Empty

    8

    7

    4

    0

    PIC space @ 6/3/*

    Empty

    8

    8

    1

    0

    PIC space @ 7/0/*

    Empty

    8

    8

    2

    0

    PIC space @ 7/1/*

    Empty

    8

    8

    3

    0

    PIC space @ 7/2/*

    Empty

    8

    8

    4

    0

    PIC space @ 7/3/*

    Empty

    9

    1

    0

    0

    Routing Engine compartment

    Filled

    Table 18 provides an example of jnxFilledEntry objects in the jnxFilledTable of a T640 router.

    Table 18: jnxFilledEntry Objects in the jnxFilledTable of a T640 Router

    Container Index

    L1

    L2

    L3

    Description

    State

    1

    1

    0

    0

    Chassis frame

    Filled

    2

    1

    0

    0

    PEM slot 0

    Empty

    2

    2

    0

    0

    PEM slot 1

    Filled

    4

    1

    1

    0

    Top left front fan slot

    Filled

    4

    1

    2

    0

    Top left middle fan slot

    Filled

    4

    1

    3

    0

    Top left rear fan slot

    Filled

    4

    1

    4

    0

    Top right front fan slot

    Filled

    4

    1

    5

    0

    Top right middle fan slot

    Filled

    4

    1

    6

    0

    Top right rear fan slot

    Filled

    4

    2

    1

    0

    Bottom left front fan slot

    Filled

    4

    2

    2

    0

    Bottom left middle fan slot

    Filled

    4

    2

    3

    0

    Bottom left rear fan slot

    Filled

    4

    2

    4

    0

    Bottom right front fan slot

    Filled

    4

    2

    5

    0

    Bottom right middle fan slot

    Filled

    4

    2

    6

    0

    Bottom right rear fan slot

    Filled

    4

    3

    1

    0

    Fourth blower from top slot

    Filled

    4

    3

    2

    0

    Bottom blower slot

    Filled

    4

    3

    3

    0

    Middle blower slot

    Filled

    4

    3

    4

    0

    Top blower slot

    Filled

    4

    3

    5

    0

    Second blower from top slot

    Filled

    7

    3

    2

    0

    FPC slot 0

    Empty

    7

    3

    3

    0

    FPC slot 0 top temperature sensor

    Empty

    7

    3

    4

    0

    FPC slot 0 bottom temperature sensor

    Empty

    7

    3

    5

    0

    FPC slot 1

    Filled

    7

    3

    6

    0

    FPC slot 1 top temperature sensor

    Filled

    7

    1

    0

    0

    FPC slot 1 bottom temperature sensor

    Filled

    7

    1

    1

    0

    FPC slot 2

    Empty

    7

    1

    2

    0

    FPC slot 2 top temperature sensor

    Empty

    7

    2

    0

    0

    FPC slot 2 bottom temperature sensor

    Empty

    7

    2

    1

    0

    FPC slot 3

    Empty

    7

    2

    2

    0

    FPC slot 3 top temperature sensor

    Empty

    7

    3

    0

    0

    FPC slot 3 bottom temperature sensor

    Empty

    7

    3

    1

    0

    FPC slot 4

    Empty

    7

    3

    2

    0

    FPC slot 4 top temperature sensor

    Empty

    7

    4

    0

    0

    FPC slot 4 bottom temperature sensor

    Empty

    7

    4

    1

    0

    FPC slot 5

    Filled

    7

    4

    2

    0

    FPC slot 5 top temperature sensor

    Filled

    7

    5

    0

    0

    FPC slot 5 bottom temperature sensor

    Filled

    7

    5

    1

    0

    FPC slot 6

    Empty

    7

    5

    2

    0

    FPC slot 6 top temperature sensor

    Empty

    7

    6

    0

    0

    FPC slot 6 bottom temperature sensor

    Empty

    7

    6

    1

    0

    FPC slot 7

    Filled

    7

    6

    2

    0

    FPC slot 7 top temperature sensor

    Filled

    7

    7

    0

    0

    FPC slot 7 bottom temperature sensor

    Filled

    8

    1

    1

    0

    PIC slot @ 0/0/*

    Empty

    8

    1

    2

    0

    PIC slot @ 0/1/*

    Empty

    8

    1

    3

    0

    PIC slot @ 0/2/*

    Empty

    8

    1

    4

    0

    PIC slot @ 0/3/*

    Empty

    8

    2

    1

    0

    PIC slot @ 1/0/*

    Filled

    8

    2

    2

    0

    PIC slot @ 1/1/*

    Filled

    8

    2

    3

    0

    PIC slot @ 1/2/*

    Filled

    8

    2

    4

    0

    PIC slot @ 1/3/*

    Empty

    8

    3

    1

    0

    PIC slot @ 2/0/*

    Empty

    8

    3

    2

    0

    PIC slot @ 2/1/*

    Empty

    8

    3

    3

    0

    PIC slot @ 2/2/*

    Empty

    8

    3

    4

    0

    PIC slot @ 2/3/*

    Empty

    8

    4

    1

    0

    PIC slot @ 3/0/*

    Empty

    8

    4

    2

    0

    PIC slot @ 3/1/*

    Empty

    8

    4

    3

    0

    PIC slot @ 3/2/*

    Empty

    8

    4

    4

    0

    PIC slot @ 3/3/*

    Empty

    8

    5

    1

    0

    PIC slot @ 4/0/*

    Empty

    8

    5

    2

    0

    PIC slot @ 4/1/*

    Empty

    8

    5

    3

    0

    PIC slot @ 4/2/*

    Empty

    8

    5

    4

    0

    PIC slot @ 4/3/*

    Empty

    8

    6

    1

    0

    PIC slot @ 5/0/*

    Filled

    8

    6

    2

    0

    PIC slot @ 5/1/*

    Filled

    8

    6

    3

    0

    PIC slot @ 5/2/*

    Filled

    8

    6

    4

    0

    PIC slot @ 5/3/*

    Empty

    8

    7

    1

    0

    PIC slot @ 6/0/*

    Empty

    8

    7

    2

    0

    PIC slot @ 6/1/*

    Empty

    8

    7

    3

    0

    PIC slot @ 6/2/*

    Empty

    8

    7

    4

    0

    PIC slot @ 6/3/*

    Empty

    8

    8

    1

    0

    PIC slot @ 7/0/*

    Filled

    8

    8

    2

    0

    PIC slot @ 7/1/*

    Filled

    8

    8

    3

    0

    PIC slot @ 7/2/*

    Filled

    8

    8

    4

    0

    PIC slot @ 7/3/*

    Filled

    9

    1

    0

    0

    Host 0 slot

    Filled

    9

    2

    0

    0

    Host 1 slot

    Filled

    10

    1

    0

    0

    FPM slot

    Filled

    11

    1

    0

    0

    SCG slot 0

    Filled

    11

    2

    0

    0

    SCG slot 1

    Filled

    12

    1

    0

    0

    CB slot 0

    Filled

    12

    2

    0

    0

    CB slot 1

    Filled

    13

    1

    0

    0

    CIP slot

    Filled

    14

    1

    0

    0

    SPMB slot 0

    Filled

    14

    2

    0

    0

    SPMB slot 1

    Filled

    15

    1

    0

    0

    SIB slot 0

    Filled

    15

    2

    0

    0

    SIB slot 1

    Filled

    15

    3

    0

    0

    SIB slot 2

    Filled

    15

    4

    0

    0

    SIB slot 3

    Filled

    15

    5

    0

    0

    SIB slot 4

    Filled

    Table 19 provides an example of jnxFilledEntry objects in the jnxFilledTable of a T320 router.

    Table 19: jnxFilledEntry Objects in the jnxFilledTable of a T320 Router

    Container Index

    L1

    L2

    L3

    Description

    State

    1

    1

    0

    0

    Chassis frame

    Filled

    2

    1

    0

    0

    PEM slot 0

    Filled

    2

    2

    0

    0

    PEM slot 1

    Empty

    4

    1

    1

    0

    Top left front fan slot

    Filled

    4

    1

    2

    0

    Top left middle fan slot

    Filled

    4

    1

    3

    0

    Top left rear fan slot

    Filled

    4

    1

    4

    0

    Top right front fan slot

    Filled

    4

    1

    5

    0

    Top right middle fan slot

    Filled

    4

    1

    6

    0

    Top right rear fan slot

    Filled

    4

    2

    1

    0

    Bottom left front fan slot

    Filled

    4

    2

    2

    0

    Bottom left middle fan slot

    Filled

    4

    2

    3

    0

    Bottom left rear fan slot

    Filled

    4

    2

    4

    0

    Bottom right front fan slot

    Filled

    4

    2

    5

    0

    Bottom right middle fan slot

    Filled

    4

    2

    6

    0

    Bottom right rear fan slot

    Filled

    4

    3

    1

    0

    Rear tray top fan slot

    Filled

    4

    3

    2

    0

    Rear tray second fan slot

    Filled

    4

    3

    3

    0

    Rear tray middle fan slot

    Filled

    4

    3

    4

    0

    Rear tray fourth fan slot

    Filled

    4

    3

    5

    0

    Rear tray bottom fan slot

    Filled

    7

    1

    0

    0

    FPC slot 0

    Empty

    7

    1

    1

    0

    FPC slot top temperature sensor

    Empty

    7

    1

    2

    0

    FPC slot 0 bottom temperature sensor

    Empty

    7

    2

    0

    0

    FPC slot 1

    Empty

    7

    2

    1

    0

    FPC slot 1 top temperature sensor

    Empty

    7

    2

    2

    0

    FPC slot 1 bottom temperature sensor

    Empty

    7

    3

    0

    0

    FPC slot 2

    Empty

    7

    3

    1

    0

    FPC slot 2 top temperature sensor

    Empty

    7

    3

    2

    0

    FPC slot 2 bottom temperature sensor

    Empty

    7

    4

    0

    0

    FPC slot 3

    Filled

    7

    4

    1

    0

    FPC slot 3 top temperature sensor

    Filled

    7

    4

    2

    0

    FPC slot 3 bottom temperature sensor

    Filled

    7

    5

    1

    0

    FPC slot 4

    Empty

    7

    5

    2

    0

    FPC slot 4 top temperature sensor

    Empty

    7

    5

    0

    0

    FPC slot 4 bottom temperature sensor

    Empty

    7

    6

    1

    0

    FPC slot 5

    Empty

    7

    6

    2

    0

    FPC slot 5 top temperature sensor

    Empty

    7

    6

    0

    0

    FPC slot 5 bottom temperature sensor

    Empty

    7

    7

    1

    0

    FPC slot 6

    Empty

    7

    7

    2

    0

    FPC slot 6 top temperature sensor

    Empty

    7

    7

    0

    0

    FPC slot 6 bottom temperature sensor

    Empty

    7

    8

    1

    0

    FPC slot 7

    Empty

    7

    8

    2

    0

    FPC slot 7 top temperature sensor

    Empty

    7

    8

    0

    0

    FPC slot 7 bottom temperature sensor

    Empty

    8

    1

    1

    0

    PIC slot @ 0/0/*

    Empty

    8

    1

    2

    0

    PIC slot @ 0/1/*

    Empty

    8

    2

    1

    0

    PIC slot @ 1/0/*

    Empty

    8

    2

    2

    0

    PIC slot @ 1/1/*

    Empty

    8

    3

    1

    0

    PIC slot @ 2/0/*

    Empty

    8

    3

    2

    0

    PIC slot @ 2/1/*

    Empty

    8

    4

    1

    0

    PIC slot @ 3/0/*

    Filled

    8

    4

    2

    0

    PIC slot @ 3/1/*

    Filled

    8

    5

    1

    0

    PIC slot @ 4/0/*

    Empty

    8

    5

    2

    0

    PIC slot @ 4/1/*

    Empty

    8

    6

    1

    0

    PIC slot @ 5/0/*

    Empty

    8

    6

    2

    0

    PIC slot @ 5/1/*

    Empty

    8

    7

    1

    0

    PIC slot @ 6/0/*

    Empty

    8

    7

    2

    0

    PIC slot @ 6/1/*

    Empty

    8

    8

    1

    0

    PIC slot @ 7/0/*

    Empty

    8

    8

    2

    0

    PIC slot @ 7/1/*

    Empty

    9

    1

    0

    0

    Host 0 slot

    Filled

    9

    2

    0

    0

    Host 1 slot

    Filled

    10

    1

    0

    0

    FPM slot

    Filled

    11

    1

    0

    0

    SCG slot 0

    Filled

    11

    2

    0

    0

    SCG slot 1

    Filled

    12

    1

    0

    0

    CB slot 0

    Filled

    12

    2

    0

    0

    CB slot 1

    Filled

    13

    1

    0

    0

    CIP slot

    Filled

    14

    1

    0

    0

    SPMB slot 0

    Filled

    14

    2

    0

    0

    SPMB slot 1

    Filled

    15

    1

    0

    0

    SIB slot 0

    Filled

    15

    2

    0

    0

    SIB slot 1

    Filled

    15

    3

    0

    0

    SIB slot 2

    Filled

    Table 20 provides an example of jnxFilledEntry objects in the jnxFilledTable of a T4000 router.

    Table 20: jnxFilledEntry Objects in the jnxFilledTable of a T4000 Router

    Container Index

    L1

    L2

    L3

    Description

    State

    1

    1

    0

    0

    Chassis frame

    Filled

    2

    1

    0

    0

    PEM slot 0

    Empty

    2

    2

    0

    0

    PEM slot 1

    Filled

    4

    1

    0

    0

    Front Top Fan Tray slot

    Filled

    4

    1

    1

    0

    Top Left Front Fan slot

    Filled

    4

    1

    2

    0

    Top Left Middle Fan slot

    Filled

    4

    1

    3

    0

    Top Left Rear Fan slot

    Filled

    4

    1

    4

    0

    Top Right Front fan slot

    Filled

    4

    1

    5

    0

    Top Right Middle fan slot

    Filled

    4

    1

    6

    0

    Top Right Rear Fan slot

    Filled

    4

    2

    0

    0

    Front Bottom Fan slot

    Filled

    4

    2

    1

    0

    Bottom Left Front Fan slot

    Filled

    4

    2

    2

    0

    Bottom Left Middle Fan slot

    Filled

    4

    2

    3

    0

    BottomLeft Rear Fan slot

    Filled

    4

    2

    4

    0

    Bottom Right Front Fan slot

    Filled

    4

    2

    5

    0

    Bottom Right Middle Fan slot

    Filled

    4

    2

    6

    0

    Bottom Right Rear Fan slot

    Filled

    4

    3

    0

    0

    Rear Fan Tray slot

    Filled

    4

    3

    1

    0

    Rear Tray Top Fan slot

    Filled

    4

    3

    2

    0

    Rear Tray Second Fan slot

    Filled

    4

    3

    3

    0

    Rear Tray Third Fan slot

    Empty

    4

    3

    4

    0

    Rear Tray Fourth Fan slot

    Empty

    4

    3

    5

    0

    Rear Tray Fifth Fan slot

    Empty

    4

    3

    6

    0

    Rear Tray Sixth Fan slot

    Empty

    4

    3

    7

    0

    Rear Tray Seventh Fan slot

    Empty

    4

    3

    8

    0

    Rear Tray Bottom Fan slot

    Empty

    7

    1

    3

    0

    FPC slot 0 MMB0

    Filled

    7

    1

    4

    0

    FPC slot 0 MMB1

    Filled

    7

    2

    0

    0

    FPC slot 1

    Empty

    7

    2

    1

    0

    FPC slot 1 top temperature sensor

    Empty

    7

    2

    2

    0

    FPCslot 1 bottom temperature sensor

    Empty

    7

    2

    3

    0

    FPC slot 1 MMB0

    Empty

    7

    2

    4

    0

    FPC slot 1 MMB1

    Empty

    7

    3

    0

    0

    FPC slot 2

    Empty

    7

    3

    1

    0

    FPC slot 2 top temperature sensor

    Empty

    7

    3

    2

    0

    FPC slot 2 bottom temperature sensor

    Empty

    7

    3

    3

    0

    FPC slot 2 MMB0

    Empty

    7

    3

    4

    0

    FPC slot 2 MMB1

    Filled

    7

    4

    0

    0

    FPC slot 3

    Filled

    7

    4

    1

    0

    FPC slot 3 top temperature sensor

    Filled

    7

    4

    2

    0

    FPC slot 3 bottom temperature sensor

    Filled

    7

    4

    3

    0

    FPC slot 3 MMB0

    Filled

    7

    4

    4

    0

    FPC slot 3 MMB1

    Filled

    7

    5

    0

    0

    FPC slot 4

    Filled

    7

    5

    1

    0

    FPC slot 4 top temperature sensor

    Empty

    7

    5

    2

    0

    FPC slot 4 bottom temperature sensor

    Empty

    7

    5

    3

    0

    FPC slot 4 MMB0

    Empty

    7

    5

    4

    0

    FPC slot 4 MMB1

    Empty

    7

    5

    5

    0

    FPC slot 5

    Empty

    7

    6

    1

    0

    FPC slot 5 top temperature sensor

    Empty

    7

    6

    2

    0

    FPC slot 5 bottom temperature sensor

    Filled

    7

    6

    3

    0

    FPC slot 5 MMB0

    Filled

    7

    6

    4

    0

    FPC slot 5 MMB1

    Filled

    7

    7

    0

    0

    FPC slot 6

    Empty

    7

    7

    1

    0

    FPC slot 6 top temperature sensor

    Filled

    7

    7

    2

    0

    FPC slot 6 bottom temperature sensor

    Filled

    7

    7

    3

    0

    FPC slot 6 MMB0

    Filled

    7

    7

    4

    0

    FPC slot 6 MMB1

    Empty

    7

    8

    0

    0

    FPC slot 7

    Filled

    7

    8

    1

    0

    FPC slot 7 top temperature sensor

    Filled

    7

    8

    2

    0

    FPC slot 7 bottom temperature sensor

    Filled

    7

    8

    3

    0

    FPC slot 7 MMB0

    Filled

    7

    8

    4

    0

    FPC slot 7 MMB1

    Filled

    8

    1

    4

    0

    PIC slot @ 0/3/*

    Empty

    8

    2

    1

    0

    PIC slot @ 1/0/*

    Filled

    8

    2

    2

    0

    PIC slot @ 1/1/*

    Filled

    8

    2

    3

    0

    PIC slot @ 1/2/*

    Filled

    8

    2

    4

    0

    PIC slot @ 1/3/*

    Empty

    8

    3

    1

    0

    PIC slot @ 2/0/*

    Empty

    8

    3

    2

    0

    PIC slot @ 2/1/*

    Empty

    8

    3

    3

    0

    PIC slot @ 2/2/*

    Empty

    8

    3

    4

    0

    PIC slot @ 2/3/*

    Empty

    8

    4

    1

    0

    PIC slot @ 3/0/*

    Empty

    8

    4

    2

    0

    PIC slot @ 3/1/*

    Empty

    8

    4

    3

    0

    PIC slot @ 3/2/*

    Empty

    8

    4

    4

    0

    PIC slot @ 3/3/*

    Empty

    8

    5

    1

    0

    PIC slot @ 4/0/*

    Empty

    8

    5

    2

    0

    PIC slot @ 4/1/*

    Empty

    8

    5

    4

    0

    PIC slot @ 4/3/*

    Empty

    8

    6

    1

    0

    PIC slot @ 5/0/*

    Filled

    8

    6

    2

    0

    PIC slot @ 5/1/*

    Filled

    8

    6

    3

    0

    PIC slot @ 5/2/*

    Filled

    8

    6

    4

    0

    PIC slot @ 5/3/*

    Empty

    8

    7

    1

    0

    PIC slot @ 6/0/*

    Empty

    8

    7

    2

    0

    PIC slot @ 6/1/*

    Empty

    8

    7

    3

    0

    PIC slot @ 6/2/*

    Empty

    8

    7

    4

    0

    PIC slot @ 6/3/*

    Empty

    8

    8

    1

    0

    PIC slot @ 7/0/*

    Filled

    8

    8

    2

    0

    PIC slot @ 7/1/*

    Filled

    8

    8

    3

    0

    PIC slot @ 7/2/*

    Filled

    8

    8

    4

    0

    PIC slot @ 7/3/*

    Filled

    9

    1

    0

    0

    Routing Engine 0 slot

    Filled

    9

    2

    0

    0

    Routing Engine 1 slot

    Filled

    10

    1

    1

    0

    FPM GBUS slot

    Filled

    10

    1

    2

    0

    FPM Display slot

    Filled

    11

    1

    0

    0

    SCG slot 0

    Filled

    11

    2

    0

    0

    SCG slot 1

    Filled

    12

    1

    0

    0

    CB slot 0

    Filled

    12

    2

    0

    0

    CB slot 1

    Filled

    13

    1

    0

    0

    CIP slot

    Filled

    14

    1

    0

    0

    SPMB slot 0

    Filled

    14

    2

    0

    0

    SPMB slot 1

    Filled

    15

    1

    0

    0

    SIB slot 0

    Filled

    15

    2

    0

    0

    SIB slot 1

    Filled

    15

    3

    0

    0

    SIB slot 2

    Filled

    15

    4

    0

    0

    SIB slot 3

    Filled

    15

    5

    0

    0

    SIB slot 4

    Filled

    jnxOperatingTable

    The object identifier for the jnxOperatingTable is {jnxBoxAnatomy 13}. This object reports the operating status of various components such as CPU, buffers, and memory.

    Juniper Networks devices implement packet forwarding and routing functions with two separate components, the Packet Forwarding Engine and the Routing Engine, to ensure stability. The clean separation of these two functions permits superior forwarding performance and a highly reliable operating system. Therefore, it is not necessary to monitor CPU, memory, and buffer utilization, as is the case with traditional, monolithic code base routers. The Routing Engine has its own CPU, memory, and buffers—separate from those of the Packet Forwarding Engine. The ASIC-based Packet Forwarding Engine forwards packets on all interfaces at wire speed, eliminating the need to monitor packet buffers being exhausted. As a result, CPU utilization under 2 percent is normal.

    Entries in the jnxOperatingTable are represented by the jnxOperatingEntry object, whose object identifier is {jnxOperatingTable 1}.

    The jnxOperatingTable describes the status of specific objects, which are described as follows:

    • jnxOperatingContents—The associated jnxContentsIndex in the jnxContentsTable, whose object identifier is {jnxOperatingEntry 1}.
    • jnxOperatingL1Index—The level-one index of the container housing the entry, whose object identifier is {jnxOperatingEntry 2}.
    • jnxOperatingL2Index—The level-two index of the container housing the entry, whose object identifier is {jnxOperatingEntry 3}.
    • jnxOperatingL3Index—The level-three index of the container housing the entry, whose object identifier is {jnxOperatingEntry 4}.
    • jnxOperatingDescr—The name or detailed description of the entry, whose object identifier is {jnxOperatingEntry 5}.
    • jnxOperatingState—The operating state of the entry, whose object identifier is {jnxOperatingEntry 6}. The state can be any of the following:
      • Unknown(1)—State of the component is unknown or unavailable
      • Running(2)—Up and running as an active primary
      • Ready(3)—Ready to run; not running yet
      • Reset(4)—Held in reset; not ready yet
      • RunningAtFullSpeed(5)—Valid for fans only
      • Down(6)—Power supply is down or off
      • Standby(7)—Running as a standby backup
    • jnxOperatingTemp—The entry’s temperature, in degrees Celsius (°C), whose object identifier is {jnxOperatingEntry 7}.
    • jnxOperatingCPU—The CPU utilization percentage of the entry, whose object identifier is {jnxOperatingEntry 8}. It is valid for the Control Board, the FPC, and the Routing Engine. It is a 5-second rolling-weighted average calculated every second for each of the CPUs. The value is sent to the Routing Engine every 10 seconds. The value for the Routing Engine is calculated as the average CPU usage over a 5-second period. The chassis process (chassisd) computes this value for every 5-second period and returns the latest value from the cache when probed for the value of jnxOperatingCPU.9.1.0.0, which maps to the Routing Engine CPU. The Routing Engine is the only object of interest; the rest of the objects are most likely zero because CPUs on those cards are only used for management purposes.

      The following three MIB objects provide for better CPU utilization reporting over SNMP:

      • jnxOperating1MinAvgCPU—Indicates the average utilization of CPU during the last minute.
      • jnxOperating5MinAvgCPU—Indicates the average utilization of CPU during the last 5-minute period.
      • jnxOperating15MinAvgCPU—Indicates the average utilization of CPU during the last 15-minute period.

        All these objects return a zero value if the data is not available or is not applicable.

    • jnxOperatingISR—The CPU utilization percentage of the entry in relation to the interrupt service routing (ISR), whose object identifier is {jnxOperatingEntry 9}.
    • jnxOperatingDRAMSize—The DRAM size of the entry, in bytes, whose object identifier is {jnxOperatingEntry 10}. It is valid for the FPC, Routing Engine, and Control Board.
    • jnxOperatingBuffer—The buffer pool utilization of the entry (a percentage), whose object identifier is {jnxOperatingEntry 11}. It is valid for the FPC and Control Board as a percentage of utilization. Buffers are normally fixed-length memory preallocated for read/write, input/output, or reception/transmission. A measurement against these buffers gives some indication of how busy the system is. The larger the percentage utilization, the busier the system. In terms of absolute numbers, the bigger the buffer size, the better the system can handle bursty traffic patterns.
    • jnxOperatingHeap—The heap utilization of the entry, whose object identifier is {jnxOperatingEntry 12}.
    • jnxOperatingUpTime—The time interval, in 10-millisecond periods, that the entry has been up and running, whose object identifier is {jnxOperatingEntry 13}.
    • jnxOperatingLastRestart—The value of sysUpTime when the entry was last restarted, whose object identifier is {jnxOperatingEntry 14}.
    • jnxOperatingMemory—The entry’s installed memory size, in megabytes (MB), whose object identifier is {jnxOperatingEntry 15}.
    • jnxOperatingStateOrdered—The operating state of the entry, whose object identifier is {jnxOperatingEntry 16}. The state is represented by one of the following values:
      • Running(1)—Up and running as an active primary
      • Standby(2)—Running as a standby backup
      • Ready(3)—Ready to run; not running yet
      • RunningAtFullSpeed(4)—Valid for fans only
      • Reset(5)—Held in reset; not ready yet
      • Down(6)—Power supply is down or off
      • Unknown(7)—State of the component is unknown or unavailable
    • jnxOperatingBufferCP—The buffer pool utilization of the entry, in percentage, in the control plane, whose object identifier is {jnxOperatingEntry 23}.
    • jnxOperatingMemoryCP—The entry’s installed memory size, in megabytes (MB), in the control plane, whose object identifier is jnxOperatingEntry 24}.

    Table 21 through Table 23 provide examples of jnxOperatingEntry objects. The following column headings for each table are abbreviated to correspond to the parts of the jnxOperatingEntry objects:

    • Contents index—jnxOperatingContents
    • L1—jnxOperatingL1Index
    • L2—jnxOperatingL2Index
    • L3—jnxOperatingL3Index
    • Description—jnxOperatingDescr
    • State—jnxOperatingState
    • Temp—jnxOperatingTemp
    • CPU—jnxOperatingCPU
    • ISR—jnxOperatingISR
    • DRAM—jnxOperatingDRAMSize
    • Buffer—jnxOperatingBuffer
    • BufferCP—jnxOperatingBufferCP
    • Heap—jnxOperatingHeap
    • UpTime—jnxOperatingUpTime
    • Last Restart—jnxOperatingLastRestart
    • Memory—jnxOperatingMemory
    • MemoryCP—jnxOperatingMemoryCP

    Table 21 provides an example of jnxOperatingEntry objects in the jnxOperatingTable of an M20 router.

    Table 21: jnxOperatingEntry Objects in the jnxOperatingTable of an M20 Router

    Index

    L1

    L2

    L3

    Description

    State

    Temp

    CPU

    ISR

    DRAM

    Buffer

    Heap

    UpTime

    LastRestart

    Memory

    1

    1

    0

    0

    Midplane

    Running

    26

    0

    0

    0

    0

    0

    0

    0:0:00:00.0

    0

    2

    1

    0

    0

    Power supply A

    Running

    28

    0

    0

    0

    0

    0

    0

    0:0:00:00.0

    0

    2

    2

    0

    0

    Power supply B

    Running

    29

    0

    0

    0

    0

    0

    0

    0:0:00:00.0

    0

    4

    1

    0

    0

    Front top fan

    Running

    0

    0

    0

    0

    0

    0

    0

    0:0:00:00.0

    0

    4

    2

    0

    0

    Front middle fan

    Running

    0

    0

    0

    0

    0

    0

    0

    0:0:00:00.0

    0

    4

    3

    0

    0

    Front bottom fan

    Running

    0

    0

    0

    0

    0

    0

    0

    0:0:00:00.0

    0

    4

    4

    0

    0

    Rear fan

    Running

    0

    0

    0

    0

    0

    0

    0

    0:0:00:00.0

    0

    6

    1

    0

    0

    SSB 0

    Running

    30

    0

    0

    671088

    6

    0

    67038195

    0:0:00:35.41

    64

    7

    1

    0

    0

    FPC @ 0/*/*

    Running

    31

    0

    0

    83886

    3

    0

    67035034

    0:0:01:06.91

    8

    7

    2

    0

    0

    FPC @ 1/*/*

    Running

    33

    0

    0

    83886

    4

    0

    67034422

    0:0:01:13.04

    8

    7

    3

    0

    0

    FPC @ 2/*/*

    Running

    31

    0

    0

    83886

    3

    0

    67033809

    0:0:01:19.18

    8

    9

    1

    0

    0

    Routing Engine 0

    Running

    29

    4

    0

    802738

    0

    0

    67046146

    0:0:00:00.00

    765

    To verify the size of the memory, use the show chassis fpc, show chassis routing-engine, and show chassis ssb commands.

    Table 22 provides an example of jnxOperatingEntry objects in the jnxOperatingTable of a T640 router.

    Table 22: jnxOperatingEntry Objects in the jnxOperatingTable of a T640 Router

    Index

    L1

    L2

    L3

    Description

    State

    Temp

    CPU

    ISR

    DRAM

    Buffer

    Heap

    UpTime

    LastRestart

    Memory

    1

    1

    0

    0

    Midplane

    Running

    0

    2

    2

    0

    0

    PEM 1

    Running

    29

    4

    1

    1

    0

    Top left front fan

    Running

    0

    4

    1

    2

    0

    Top left middle fan

    Running

    0

    4

    1

    3

    0

    Top left rear fan

    Running

    0

    0

    0

    0

    0

    0

    0

    0:0:00:00.00

    0

    4

    1

    4

    0

    Top right front fan

    Running

    0

    0

    0

    0

    0

    0

    0

    0:0:00:00.00

    0

    4

    1

    5

    0

    Top right middle fan

    Running

    0

    0

    0

    0

    0

    0

    0

    0:0:00:00.00

    0

    4

    1

    6

    0

    Top right rear fan

    Running

    0

    0

    0

    0

    0

    0

    0

    0:0:00:00.00

    0

    4

    2

    1

    0

    Bottom left front fan

    Running

    0

    0

    0

    0

    0

    0

    0

    0:0:00:00.00

    0

    4

    2

    2

    0

    Bottom left middle fan

    Running

    0

    0

    0

    0

    0

    0

    0

    0:0:00:00.00

    0

    4

    2

    3

    0

    Bottom left rear fan

    Running

    0

    0

    0

    0

    0

    0

    0

    0:0:00:00.00

    0

    4

    2

    4

    0

    Bottom right front fan

    Running

    0

    0

    0

    0

    0

    0

    0

    0:0:00:00.00

    0

    4

    2

    5

    0

    Bottom right middle fan

    Running

    0

    0

    0

    0

    0

    0

    0

    0:0:00:00.00

    0

    4

    3

    1

    0

    Bottom right rear fan

    Running

    0

    0

    0

    0

    0

    0

    0

    0:0:00:00.00

    0

    4

    3

    1

    0

    Bottom blower

    Running

    0

    0

    0

    0

    0

    0

    0

    0:0:00:00.00

    0

    4

    3

    2

    0

    Bottom blower

    Running

    0

    0

    0

    0

    0

    0

    0

    0:0:00:00.00

    0

    4

    3

    3

    0

    Middle blower

    Running

    0

    0

    0

    0

    0

    0

    0

    0:0:00:00.00

    0

    4

    3

    4

    0

    Top blower

    Running

    0

    0

    0

    0

    0

    0

    0

    0:0:00:00.00

    0

    4

    3

    5

    0

    Second blower from top

    Running

    0

    0

    0

    0

    0

    0

    0

    0:0:00:00.00

    0

    7

    2

    0

    0

    FPC @ 1/*/*

    Running

    0

    1

    0

    512

    41

    3

    138367

    0:18:56:48.81

    512

    7

    2

    1

    0

    FPC @ 1/0/* top temperature sensor

    Running

    35

    0

    0

    0

    0

    0

    0

    0:18:56:48.81

    0

    7

    2

    2

    0

    FPC @ 1/1/* bottom temperature sensor

    Running

    32

    0

    0

    0

    0

    0

    0

    0:18:56:48.81

    0

    7

    6

    0

    0

    FPC @ 5/*/*

    Running

    0

    3

    0

    256

    41

    14

    136976

    0:18:57:02.71

    256

    7

    6

    1

    0

    FPC @ 5/0/* top temperature sensor

    Running

    44

    0

    0

    0

    0

    0

    0

    0:18:57:02.71

    0

    7

    6

    2

    0

    FPC @ 5/1/* bottom temperature sensor

    Running

    33

    0

    0

    0

    0

    0

    0

    0:18:57:02.71

    0

    7

    8

    0

    0

    FPC @ 7/*/*

    Running

    0

    2

    0

    256

    41

    7

    137963

    0:18:56:52.85

    256

    7

    8

    1

    0

    FPC @ 7/0/* top temperature sensor

    Running

    38

    0

    0

    0

    0

    0

    0

    0:18:56:52.85

    0

    7

    8

    2

    0

    FPC @ 7/1/* bottom temperature sensor

    Running

    33

    0

    0

    0

    0

    0

    0

    0:18:56:52.85

    0

    9

    1

    0

    0

    Host 0

    Running

    35

    0

    0

    2048

    0

    0

    6963005

    0:19:20:30.07

    2048

    9

    2

    0

    0

    Host 1

    Standby

    32

    2

    0

    2048

    0

    0

    24401100

    2:19:46:51.00

    2048

    10

    1

    0

    0

    FPM

    Running

    30

    0

    0

    0

    0

    0

    0

    0:0:00:00.00

    0

    11

    1

    0

    0

    SCG 0

    Running

    36

    0

    0

    0

    0

    0

    0

    0:0:00:00.00

    0

    11

    2

    0

    0

    SCG 1

    Standby

    35

    0

    0

    0

    0

    0

    0

    0:0:00:00.00

    0

    12

    1

    0

    0

    CB 0

    Running

    36

    0

    0

    0

    0

    0

    0

    0:0:00:00.00

    0

    12

    2

    0

    0

    CB 1

    Standby

    39

    0

    0

    0

    0

    0

    0

    0:0:00:00.00

    0

    14

    1

    0

    0

    SPMB 0

    Running

    36

    1

    0

    128

    40

    0

    142576

    0:18:56:06.72

    128

    14

    2

    0

    0

    SPMB 1

    Standby

    39

    0

    0

    128

    40

    0

    142447

    0:18:56:08.01

    128

    15

    1

    0

    0

    SIB 0

    Unknown

    40

    0

    0

    0

    0

    0

    0

    0:0:00:00.00

    0

    15

    2

    0

    0

    SIB 1

    Unknown

    39

    0

    0

    0

    0

    0

    0

    0:0:00:00.00

    0

    15

    3

    0

    0

    SIB 2

    Unknown

    39

    0

    0

    0

    0

    0

    0

    0:0:00:00.00

    0

    15

    4

    0

    0

    SIB 3

    Unknown

    40

    0

    0

    0

    0

    0

    0

    0:0:00:00.00

    0

    15

    5

    0

    0

    SIB 4

    Unknown

    40

    0

    0

    0

    0

    0

    0

    0:0:00:00.00

    0

    Table 23 provides an example of jnxOperatingEntry objects in the jnxOperatingTable of a T320 router.

    Table 23: jnxOperatingEntry Objects in the jnxOperatingTable of a T320 Router

    Index

    L1

    L2

    L3

    Description

    State

    Temp

    CPU

    ISR

    DRAM

    Buffer

    Heap

    UpTime

    LastRestart

    Memory

    1

    1

    0

    0

    Midplane

    Running

    0

    0

    0

    0

    0

    0

    0

    (0) 0:00:00.00

    0

    2

    1

    0

    0

    PEM 0

    Running

    0

    0

    0

    0

    0

    0

    0

    (0) 0:00:00.00

    0

    4

    1

    1

    0

    Top left front fan

    Running

    0

    0

    0

    0

    0

    0

    0

    (0) 0:00:00.00

    0

    4

    1

    2

    0

    Top left middle fan

    Running

    0

    0

    0

    0

    0

    0

    0

    (0) 0:00:00.00

    0

    4

    1

    3

    0

    Top left rear fan

    Running

    0

    0

    0

    0

    0

    0

    0

    (0) 0:00:00.00

    0

    4

    1

    4

    0

    Top right front fan

    Running

    0

    0

    0

    0

    0

    0

    0

    (0) 0:00:00.00

    0

    4

    1

    5

    0

    Top right middle fan

    Running

    0

    0

    0

    0

    0

    0

    0

    (0) 0:00:00.00

    0

    4

    2

    6

    0

    Top right rear fan

    Running

    0

    0

    0

    0

    0

    0

    0

    (0) 0:00:00.00

    0

    4

    2

    1

    0

    Bottom left front fan

    Running

    0

    0

    0

    0

    0

    0

    0

    (0) 0:00:00.00

    0

    4

    2

    2

    0

    Bottom left middle fan

    Running

    0

    0

    0

    0

    0

    0

    0

    (0) 0:00:00.00

    0

    4

    2

    3

    0

    Bottom left rear fan

    Running

    0

    0

    0

    0

    0

    0

    0

    (0) 0:00:00.00

    0

    4

    2

    4

    0

    Bottom right front fan

    Running

    0

    0

    0

    0

    0

    0

    0

    (0) 0:00:00.00

    0

    4

    2

    5

    0

    Bottom right middle fan

    Running

    0

    0

    0

    0

    0

    0

    0

    (0) 0:00:00.00

    0

    4

    2

    6

    0

    Bottom right rear fan

    Running

    0

    0

    0

    0

    0

    0

    0

    (0) 0:00:00.00

    0

    4

    3

    1

    0

    Rear tray top fan

    Running

    0

    0

    0

    0

    0

    0

    0

    (0) 0:00:00.00

    0

    4

    3

    2

    0

    Rear tray second fan

    Running

    0

    0

    0

    0

    0

    0

    0

    (0) 0:00:00.00

    0

    4

    3

    3

    0

    Rear tray middle fan

    Running

    0

    0

    0

    0

    0

    0

    0

    (0) 0:00:00.00

    0

    4

    3

    4

    0

    Rear tray fourth fan

    Running

    0

    0

    0

    0

    0

    0

    0

    (0) 0:00:00.00

    0

    4

    3

    5

    0

    Rear tray bottom fan

    Running

    0

    0

    0

    0

    0

    0

    0

    (0) 0:00:00.00

    0

    7

    4

    0

    0

    FPC @ 3/*/*

    Running

    0

    1

    0

    256

    41

    7

    6568428

    (26190949) 3 days, 0:45:09.49

    256

    7

    4

    1

    0

    FPC @ 3/0/* top temperature sensor

    Running

    41

    0

    0

    0

    0

    0

    0

    (26190949) 3 days, 0:45:09.49

    0

    7

    4

    2

    0

    FPC @ 3/1/* bottom temperature sensor

    Running

    37

    0

    0

    0

    0

    0

    0

    (26190949) 3 days, 0:45:09.49

    0

    9

    1

    0

    0

    Host 0

    Running

    34

    1

    0

    2048

    0

    0

    32763001

    (32763004) 3 days, 19:00:30.04

    2048

    9

    2

    0

    0

    Host 1

    Standby

    32

    1

    0

    2048

    0

    0

    110271900

    (110271900) 12 days, 18:18:39.00

    2048

    10

    1

    0

    0

    FPM

    Running

    30

    0

    0

    0

    0

    0

    0

    (0) 0:00:00.00

    0

    11

    1

    0

    0

    SCG 0

    Running

    33

    0

    0

    0

    0

    0

    0

    (0) 0:00:00.00

    0

    11

    2

    0

    0

    SCG 1

    Standby

    31

    0

    0

    0

    0

    0

    0

    (0) 0:00:00.00

    0

    12

    1

    0

    0

    CB 0

    Running

    37

    0

    0

    0

    0

    0

    0

    (0) 0:00:00.00

    0

    12

    2

    0

    0

    CB 1

    Standby

    34

    0

    0

    0

    0

    0

    0

    (0) 0:00:00.00

    0

    14

    1

    0

    0

    SPMB 0

    Running

    36

    0

    0

    128

    40

    0

    6572381

    (26186997) 3 days, 0:44:29.97

    128

    14

    2

    0

    0

    SPMB 1

    Standby

    36

    1

    0

    128

    40

    0

    6572465

    (26186913) 3 days, 0:44:29.13

    128

    15

    1

    0

    0

    SIB 0

    Standby

    36

    0

    0

    0

    0

    0

    0

    (0) 0:00:00.00

    0

    15

    2

    0

    0

    SIB 1

    Running

    36

    0

    0

    0

    0

    0

    0

    (0) 0:00:00.00

    0

    15

    3

    0

    0

    SIB 2

    Running

    38

    0

    0

    0

    0

    0

    0

    (0) 0:00:00.00

    0

    Table 24 provides an example of jnxOperatingEntry objects in the jnxOperatingTable of a T4000 router.

    Table 24: jnxOperatingEntry Objects in the jnxOperatingTable of a T4000 Router

    Index

    L1

    L2

    L3

    Description

    State

    Temp

    CPU

    ISR

    DRAM

    Buffer

    Heap

    UpTime

    LastRestart

    Memory

    1

    1

    0

    0

    Midplane

    Running

    0

    0

    0

    0

    0

    0

    2494800

    0

    0

    2

    1

    0

    0

    PEM 1

    Running

    29

    0

    0

    0

    0

    0

    2494800

    0

    0

    4

    1

    0

    0

    Front Top fan tray

    Running

    0

    0

    0

    0

    0

    0

    2494800

    0

    0

    4

    1

    1

    0

    Top left front fan

    Running

    0

    0

    0

    0

    0

    0

    2494800

    0

    0

    4

    1

    2

    0

    Top left middle fan

    Running

    0

    0

    0

    0

    0

    0

    2494800

    0:0:00:00.00

    0

    4

    1

    3

    0

    Top left rear fan

    Running

    0

    0

    0

    0

    0

    0

    1398451

    0:0:00:00.00

    0

    4

    1

    4

    0

    Top right front fan

    Running

    0

    0

    0

    0

    0

    0

    1398451

    0:0:00:00.00

    0

    4

    1

    5

    0

    Top right middle fan

    Running

    0

    0

    0

    0

    0

    0

    13984511398451

    0:0:00:00.00

    0

    4

    1

    5

    0

    Top right middle fan

    Running

    0

    0

    0

    0

    0

    0

    13984511398451

    0:0:00:00.00

    0

    4

    1

    6

    0

    Top right middle fan

    Running

    0

    0

    0

    0

    0

    0

    1398451

    0:0:00:00.00

    0

    4

    2

    0

    0

    Front Bottom Fan Tray

    Running

    0

    0

    0

    0

    0

    0

    1398451

    0:0:00:00.00

    0

    4

    2

    1

    0

    Bottom Left Front fan

    Running

    0

    0

    0

    0

    0

    0

    1398451

    0:0:00:00.00

    0

    4

    2

    0

    0

    Bottom left middle fan

    Running

    0

    0

    0

    0

    0

    0

    1398451

    0:0:00:00.00

    0

    4

    2

    3

    0

    Bottom left rear fan

    Running

    0

    0

    0

    0

    0

    0

    1398451

    0:0:00:00.00

    0

    4

    2

    4

    0

    Bottom right front fan

    Running

    0

    0

    0

    0

    0

    0

    1398452

    0:0:00:00.00

    0

    4

    2

    5

    0

    Bottom right middle fan

    Running

    0

    0

    0

    0

    0

    0

    1398452

    0:0:00:00.00

    0

    4

    2

    6

    0

    Bottom Right Rear fan

    Running

    0

    0

    0

    0

    0

    0

    1398452

    0:0:00:00.00

    0

    4

    3

    0

    0

    Rear Fan Tray

    Running

    0

    0

    0

    0

    0

    0

    1398452

    0:0:00:00.00

    0

    4

    3

    1

    0

    Rear Tray Top fan

    Running

    0

    0

    0

    0

    0

    0

    1398452

    0:0:00:00.00

    0

    4

    3

    2

    0

    Rear Tray Second fan

    Running

    0

    0

    0

    0

    0

    0

    0

    0:0:00:00.00

    0

    4

    3

    3

    0

    Rear Tray Third fan

    Running

    0

    0

    0

    0

    0

    0

    0

    0:0:00:00.00

    0

    4

    3

    4

    0

    Rear Tray Fourth fan

    Running

    0

    0

    0

    0

    0

    0

    0

    0:0:00:00.00

    0

    4

    3

    6

    0

    Rear Tray Fifth fan

    Running

    0

    0

    0

    0

    0

    0

    0

    0:0:00:00.00

    0

    4

    3

    7

    0

    Rear Tray Sixth fan

    Running

    0

    0

    0

    0

    0

    0

    0

    0:0:00:00.00

    0

    4

    3

    8

    0

    Rear Tray Seventh fan

    Running

    0

    0

    0

    0

    0

    0

    0

    0:0:00:00.00

    0

    7

    2

    0

    0

    FPC Type 4-ES @ 1/*/*

    Running

    0

    1

    0

    512

    41

    3

    138367

    0:18:56:48.81

    512

    7

    2

    1

    0

    FPC Type 4-ES @ 1/*/* top temperature sensor

    Running

    35

    0

    0

    0

    0

    0

    0

    0:18:56:48.81

    0

    7

    2

    2

    0

    FPC Type 4-ES @ 1/*/* bottom temperature sensor

    Running

    32

    0

    0

    0

    0

    0

    0

    0:18:56:48.81

    0

    7

    3

    0

    0

    FPC Type 5-3D @ 2/*/*

    Running

    0

    3

    0

    256

    41

    14

    136976

    0:18:57:02.71

    256

    7

    3

    1

    0

    FPC Type 5-3D @ 2/*/* intake

    Running

    44

    0

    0

    0

    0

    0

    0

    0:18:57:02.71

    0

    7

    3

    2

    0

    FPC Type 5-3D @ 2/*/* exhaust

    Running

    33

    0

    0

    0

    0

    0

    0

    0:18:57:02.71

    0

    7

    5

    0

    0

    FPC Type 5-3D @ 4/*/*

    Running

    0

    3

    0

    256

    41

    14

    136976

    0:18:57:02.71

    256

    7

    6

    1

    0

    FPC Type 5-3D @ 4/*/* intake

    Running

    44

    0

    0

    0

    0

    0

    0

    0:18:57:02.71

    0

    7

    5

    2

    0

    FPC Type 5-3D @ 4/*/* exhaust

    Running

    33

    0

    0

    0

    0

    0

    0

    0:18:57:02.71

    0

    8

    3

    1

    0

    PIC: 12x10GE (LAN/WAN) SFPP @ 2/0/*

    Running

    0

    0

    0

    0

    0

    0

    2409241

    0:18:56:52.85

    0

    8

    3

    2

    0

    PIC: 12x10GE (LAN/WAN) SFPP @ 2/1/*

    Running

    33

    0

    0

    0

    0

    0

    0

    0:18:56:52.85

    0

    8

    5

    1

    0

    PIC: 24x10GE (LAN/WAN) SFPP @ 4/0/*

    Running

    3

    0

    0

    49

    0

    2396241

    0

    0:18:56:52.85

    0

    8

    5

    2

    0

    PIC: 12x10GE (LAN/WAN) SFPP @ 4/1/*

    Running

    33

    0

    0

    0

    0

    2392440

    0

    0:18:56:52.85

    0

    9

    1

    0

    0

    Routing Engine 0

    Running

    35

    3

    0

    805306368

    20

    0

    2494800

    0:19:20:30.07

    8950

    9

    2

    0

    0

    Routing Engine 1

    Standby

    32

    0

    0

    805306368

    0

    0

    2402100

    2:19:46:51.00

    8

    10

    1

    1

    0

    FPM GBUS

    Running

    30

    0

    0

    0

    0

    0

    1398474

    0:0:00:00.00

    0

    10

    1

    2

    0

    FPM Display

    Running

    26

    0

    0

    0

    0

    20

    1398474

    0:0:00:00.00

    0

    11

    1

    0

    0

    SCG 0

    Running

    36

    0

    0

    0

    0

    0

    577202

    0:0:00:00.00

    0

    11

    2

    0

    0

    SCG 1

    Standby

    35

    0

    0

    0

    0

    0

    0

    0:0:00:00.00

    0

    12

    1

    0

    0

    CB 0

    Running

    36

    0

    0

    0

    0

    0

    1398518

    0:0:00:00.00

    0

    12

    2

    0

    0

    CB 1

    Standby

    39

    0

    0

    0

    0

    0

    0

    0:0:00:00.00

    0

    14

    1

    0

    0

    SPMB 0

    Running

    36

    1

    0

    128

    40

    0

    142576

    0:18:56:06.72

    128

    14

    1

    0

    0

    SPMB 1

    Standby

    39

    0

    0

    128

    22

    0

    1396458

    0:18:56:08.01

    128

    15

    1

    0

    0

    SIB 0

    Unknown

    40

    0

    0

    0

    22

    0

    1396458

    0:0:00:00.00

    0

    15

    2

    0

    0

    SIB 1

    Unknown

    39

    0

    0

    0

    0

    0

    1389454

    0:0:00:00.00

    0

    15

    3

    0

    0

    SIB 2

    Unknown

    39

    0

    0

    0

    0

    0

    386470

    0:0:00:00.00

    0

    15

    4

    0

    0

    SIB 3

    Unknown

    40

    0

    0

    0

    0

    0

    1383482

    0:0:00:00.00

    0

    15

    5

    0

    0

    SIB 4

    Unknown

    40

    0

    0

    0

    0

    0

    0

    0:0:00:00.00

    0

     

    jnxRedundancyTable

    The object identifier for the jnxRedundancyTable is {jnxBoxAnatomy 14}. This object shows the internal configuration settings for the redundant subsystems or components in the chassis.

    Entries within the jnxRedundancyTable are represented by the jnxRedundancyEntry object, whose object identifier is {jnxRedundancyEntry 1}. This jnxRedundancyEntry contains the following objects, which describe the internal configuration settings for the redundant subsystems or components in the chassis:

    • jnxRedundancyContentsIndex—The index value of an entry in jnxRedundancyEntry, whose object identifier is {jnxContainersEntry 1}.
    • jnxRedundancyL1Index—The level-one index associated with the redundant component, whose object identifier is {jnxContainersEntry 2}.
    • jnxRedundancyL2Index—The level-two index associated with the redundant component, whose object identifier is {jnxContainersEntry 3}.
    • jnxRedundancyL3Index—The level-three index associated with the redundant component, whose object identifier is {jnxContainersEntry 4}.
    • jnxRedundancyDescr—The description of the redundant component, whose object identifier is {jnxContainersEntry 5}.
    • jnxRedundancyConfig—The election priority of redundancy configuration, whose object identifier is {jnxContainersEntry 6}.
    • jnxRedundancyState—The current running state of the redundant component, whose object identifier is {jnxContainersEntry 7}.
    • jnxRedundancySwitchoverCount—The total number of switchovers, defined as a change in the jnxRedundancyState from master to backup or vice versa, as perceived by the redundant component since the Routing Engine is up and running, whose object identifier is {jnxContainersEntry 8}.
    • jnxRedundancySwitchoverTime—The value of sysUpTime when the jnxRedundancyState was last switched over from master to backup or vice versa, whose object identifier is {jnxContainersEntry 9}.
    • jnxRedundancySwitchoverReason—The reason for the last switchover to the redundant component, whose object identifier is {jnxContainersEntry 10}.
    • jnxKeepaliveHeartbeat—The period of sending keepalive messages between the master and the backup subsystem, which is a system-wide preset value in seconds used by internal mastership resolution, whose object identifier is {jnxContainersEntry 11}.
    • jnxRedundancyKeepaliveTimeout—The timeout period in seconds used by the watchdog timer before it initiates a switchover to the backup subsystem, whose object identifier is {jnxContainersEntry 12}.
    • jnxRedundancyKeepaliveElapsed—The elapsed time since the redundant component received the last keepalive message from the outer subsystems, whose object identifier is {jnxContainersEntry 13}.
    • jnxRedundancyKeepaliveLoss—The total number of keepalive messages lost between the master and the backup subsystems as perceived by the redundant component since the Routing Engine is up and running, whose object identifier is {jnxContainersEntry 14}.

    Table 25 through Table 27 provide examples of jnxRedundancyEntry objects. The following column headings for each table are abbreviated to correspond to the parts of the jnxOperatingTable objects:

    • Contents index—jnxRedundancyContentsIndex
    • L1—jnxRedundancyL1Index
    • L2—jnxRedundancyL2Index
    • L3—jnxRedundancyL3Index
    • Description—jnxRedundancyDescr
    • Config—jnxRedundancyConfig
    • State—jnxRedundancyState
    • Count—jnxRedundancySwitchoverCount
    • Time—jnxRedundancySwitchoverTime
    • Reason—jnxRedundancySwitchoverReason
    • Heartbeat—jnxKeepaliveHeartbeat
    • Timeout—jnxRedundancyKeepaliveTimeout
    • Elapsed—jnxRedundancyKeepaliveElapsed
    • Loss—jnxRedundancyKeepaliveLoss

    Table 25 provides an example of jnxRedundancyEntry objects in the jnxRedundancyTable of an M20 router.

    Table 25: jnxRedundancyEntry Objects in the jnxRedundancyTable of an M20 Router

    Index

    L1

    L2

    L3

    Description

    Config

    State

    Count

    Time

    Reason

    Heart beat

    Time out

    Elapsed

    Loss

    6

    1

    0

    0

    SSB 0 Internet Processor II

    Master

    Master

    0

    3383

    Never switched

    0

    0

    0

    0

    6

    2

    0

    0

    SSB 1

    Disabled

    Disabled

    0

    0

    Never switched

    0

    0

    0

    0

    9

    1

    0

    0

    Routing Engine 0

    Master

    Master

    1

    421

    User switched

    3

    300

    1

    0

    9

    2

    0

    0

    Routing Engine 1

    Backup

    Backup

    0

    0

    Other

    0

    0

    0

    0

    To verify Routing Engine status, use the show chassis routing-engine command. Sample command output from an M20 router is as follows:

    user@host> show chassis routing-engine
    Routing Engine status:
     Slot 0:
      Current state      Master
      Election priority      Master (default)
      Temperature      26 degrees C / 78 degrees F
      DRAM                 768 Mbytes
      CPU utilization:
       User                 2 percent
       Background      0 percent
       Kernel            0 percent
       Interrupt         0 percent
       Idle                98 percent
      Model              teknor
      Serial ID      32000004f8ff1201
      Start time      2002-01-29 12:30:42 PST
      Uptime             21 hours, 17 minutes, 14 seconds
      Load averages:      1 minute  5 minute 15 minute
        0.03    0.02    0.00
    Routing Engine status:
     Slot 1:
      Current state      Backup
      Election priority  Backup (default)
      DRAM                805306368 Mbytes
      CPU utilization:
       User                0 percent
       Background      0 percent
       Kernel            1 percent
       Interrupt         0 percent
       Idle                99 percent
      Model              teknor
      Serial ID      100000078c10df01
      Start time      2002-01-24 16:47:39 PST
      Uptime             5 days, 17 hours, 14 seconds
    

    To verify SSB status, use the show chassis ssb command. Sample command output from an M20 router is as follows:

    user@host> show chassis ssb
    SSB status:
    Slot 0 information:
     State                    Master
     Temperature                24 degrees C / 75 degrees F
     CPU utilization              2 percent
     Interrupt utilization           0 percent
     Heap utilization             16 percent
     Buffer utilization           43 percent
     Total CPU DRAM              64 Mbytes
     Internet Processor II            Version 1, Foundry IBM, Part number 9
     Start time:                 2002-01-29 12:32:24 PST
     Uptime:                   21 hours, 30 minutes, 53 seconds
    Slot 1 information:
     State                    Backup
    

    Table 26 provides an example of jnxRedundancyEntry objects in the jnxRedundancyTable of a T640 router.

    Table 26: jnxRedundancyEntry Objects in the jnxRedundancyTable of a T640 Router

    Index

    L1

    L2

    L3

    Description

    Config

    State

    Count

    Time

    Reason

    Heart beat

    Time out

    Elapsed

    Loss

    9

    1

    0

    0

    Host 0

    Master

    Master

    3

    0:18:55:49.42

    User switched

    20

    300

    1

    0

    9

    2

    0

    0

    Host 1

    Backup

    Backup

    0

    0:0:00:00.00

    Other

    0

    0

    0

    0

    15

    1

    0

    0

    SIB 0

    Unknown

    Backup

    1

    0:0:00:00.00

    0

    0

    0

    0

    0

    15

    2

    0

    0

    SIB 1

    Unknown

    Master

    1

    0:0:00:00.00

    0

    0

    0

    0

    0

    15

    3

    0

    0

    SIB 2

    Unknown

    Master

    1

    0:0:00:00.00

    0

    0

    0

    0

    0

    15

    4

    0

    0

    SIB 3

    Unknown

    Master

    1

    0:0:00:00.00

    0

    0

    0

    0

    0

    15

    5

    0

    0

    SIB 4

    Unknown

    Master

    1

    0:0:00:00.00

    0

    0

    0

    0

    0

    To verify Routing Engine status, use the show chassis routing-engine command. Sample command output from a T640 router is as follows:

    user@host> show chassis routing-engine
    Routing Engine status:
      Slot 0:
        Current state        Master
        Election priority       Master (default)
        Temperature       35 degrees C / 95 degrees F
        DRAM            2048 MB
        CPU utilization:
          User             1 percent
          Background       0 percent
          Kernel           5 percent
          Interrupt        0 percent
          Idle            94 percent
        Model               unknown
        Start time     2002-03-31 14:26:49 PST
        Uptime         19 hours, 22 minutes, 13 seconds
        Load averages: 1 minute   5 minute  15 minute
           0.00       0.00       0.00
    Routing Engine status:
      Slot 1:
        Current state  Backup
        Election priority              Backup (default)
        Temperature 32 degrees C / 89 degrees F
        DRAM      2048 MB
        CPU utilization:
          User       0 percent
          Background 0 percent
          Kernel     0 percent
          Interrupt  0 percent
          Idle     100 percent
        Model          RE-3.0
        Start time     2002-03-29 14:00:18 PST
        Uptime         2 days, 19 hours, 48 minutes, 32 seconds
    

    Table 27 provides an example of jnxRedundancyEntry objects in the jnxRedundancyTable of a T320 router.

    Table 27: jnxRedundancyEntry Objects in the jnxRedundancyTable of a T320 Router

    Index

    L1

    L2

    L3

    Description

    Config

    State

    Count

    Time

    Reason

    Heart beat

    Timeout

    Elapsed

    Loss

    9

    1

    0

    0

    Host 0

    Master

    Master

    6

    (26185188)3 days, 0:44:11.88

    User switched

    20

    300

    1

    0

    9

    2

    0

    0

    Host 1

    Backup

    Backup

    0

    (0) 0:00:00.00

    Other

    0

    0

    0

    0

    15

    1

    0

    0

    SIB 0

    Backup

    Backup

    1

    (0) 0:00:00.00

    0

    0

    0

    0

    0

    15

    2

    0

    0

    SIB 1

    Master

    Master

    1

    (0) 0:00:00.00

    0

    0

    0

    0

    0

    15

    3

    0

    0

    SIB 2

    Master

    Master

    1

    (0) 0:00:00.00

    0

    0

    0

    0

    0

    To verify Routing Engine status, use the show chassis routing-engine command. Sample command output from a T320 router is as follows:

    user@host> show chassis routing-engine
    Routing Engine status:
      Slot 0:
        Current state  Master
        Election priority              Master (default)
        Temperature 34 degrees C / 93 degrees F
        DRAM      2048 MB
        CPU utilization:
          User       0 percent
          Background 0 percent
          Kernel     1 percent
          Interrupt  0 percent
          Idle      98 percent
        Model          RE-3.0
        Start time     2002-04-05 14:43:16 PST
        Uptime         17 days, 23 hours, 3 minutes, 47
    seconds
        Load averages: 1 minute   5 minute  15 minute
           0.00       0.00       0.00
    Routing Engine status:
      Slot 1:
        Current state  Backup
        Election priority              Backup (default)
        Temperature 32 degrees C / 89 degrees F
        DRAM      2048 MB
        CPU utilization:
          User       0 percent
          Background 0 percent
          Kernel     0 percent
          Interrupt  0 percent
          Idle     100 percent
        Model          RE-3.0
        Start time     2002-03-27 15:25:07 PST
        Uptime         26 days, 22 hours, 21 minutes, 44 seconds
    

    Table 28 provides an example of jnxRedundancyEntry objects in the jnxRedundancyTable of a T4000 router.

    Table 28: jnxRedundancyEntry Objects in the jnxRedundancyTable of a T4000 Router

    Index

    L1

    L2

    L3

    Description

    Config

    State

    Count

    Time

    Reason

    Heart beat

    Time out

    Elapsed

    Loss

    9

    1

    0

    0

    Routing Engine 0

    Master

    Master

    0

    0:18:55:49.42

    User switched

    20

    300

    1

    0

    9

    2

    0

    0

    Routing Engine 1

    Backup

    Backup

    0

    0:0:00:00.00

    Other

    0

    0

    0

    0

    15

    1

    0

    0

    SIB 0

    Unknown

    Backup

    0

    0:0:00:00.00

    0

    0

    0

    0

    0

    15

    2

    0

    0

    SIB 1

    Unknown

    Master

    0

    0:0:00:00.00

    0

    0

    0

    0

    0

    15

    3

    0

    0

    SIB 2

    Unknown

    Master

    0

    0:0:00:00.00

    0

    0

    0

    0

    0

    15

    4

    0

    0

    SIB 3

    Unknown

    Master

    0

    0:0:00:00.00

    0

    0

    0

    0

    0

    15

    5

    0

    0

    SIB 4

    Unknown

    Master

    0

    0:0:00:00.00

    0

    0

    0

    0

    0

    To verify Routing Engine status, use the show chassis routing-engine command. Sample command output from a T4000 router is as follows:

    user@host> show chassis routing-engine
    Routing Engine status:
      Slot 0:
        Current state                  Master
        Election priority              Master (default)
        Temperature                 33 degrees C / 91 degrees F
        CPU temperature             50 degrees C / 122 degrees F
        DRAM                      8960 MB
        Memory utilization          18 percent
        CPU utilization:
          User                       0 percent
          Background                 0 percent
          Kernel                     4 percent
          Interrupt                  1 percent
          Idle                      95 percent
        Model                          RE-DUO-1800
        Serial ID                      P737F-002248
        Start time                     2012-02-09 22:49:53 PST
        Uptime                         2 hours, 21 minutes, 35 seconds
        Last reboot reason             Router rebooted after a normal shutdown.
        Load averages:                 1 minute   5 minute  15 minute
                                           0.00       0.04       0.00
    Routing Engine status:
      Slot 1:
        Current state                  Backup
        Election priority              Backup (default)
        Temperature                 32 degrees C / 89 degrees F
        CPU temperature             46 degrees C / 114 degrees F
        DRAM                      8960 MB
        Memory utilization          24 percent
        CPU utilization:
          User                       0 percent
          Background                 0 percent
          Kernel                     0 percent
          Interrupt                  0 percent
          Idle                      99 percent
        Model                          RE-DUO-1800
        Serial ID                      P737F-002653
        Start time                     2012-02-08 20:12:51 PST
        Uptime                         1 day, 4 hours, 58 minutes, 28 seconds
        Last reboot reason             Router rebooted after a normal shutdown.

    jnxFruTable

    The object identifier for the jnxFruTable is {jnxBoxAnatomy 15}. This object shows the status of field-replaceable units (FRUs) in the chassis.

    Entries within the jnxFruTable are represented by the jnxFruEntry object, whose object identifier is {jnxFruEntry 1}. This jnxFruEntry object contains the following objects, which describe the FRUs in the chassis:

    • jnxFruContentsIndex—The index value of an entry in jnxFruEntry, whose object identifier is {jnxFruEntry 1}.
    • jnxFruL1Index—The level-one index associated with the FRU, whose object identifier is {jnxFruEntry 2}.
    • jnxFruL2Index—The level-two index associated with the FRU, whose object identifier is {jnxFruEntry 3}.
    • jnxFruL3Index—The level-three index associated with the FRU, whose object identifier is {jnxFruEntry 4}.
    • jnxFruName—The name or detailed description of the FRU, whose object identifier is {jnxFruEntry 5}.
    • jnxFruType—The FRU type, whose object identifier is {jnxFruEntry 6}. The FRU type is represented by one of the following values:
      • other(1)
      • clockGenerator(2)
      • flexiblePicConcentrator(3)
      • switchingAndForwardingModule(4)
      • controlBoard(5)
      • routingEngine(6)
      • powerEntryModule(7)
      • frontPanelModule(8)
      • switchInterfaceBoard(9)
      • processorMezzanineBoardForSIB(10)
      • portInterfaceCard(11)
      • craftInterfacePanel(12)
      • fan(13)
      • lineCardChassis(14)
      • forwardingEngineBoard(13)
      • protectedSystemDomain(13)
    • jnxFruSlot—The slot number of the FRU, whose object identifier is {jnxFruEntry 7}. This is equivalent to jnxFruL1Index. The slot number is zero if unavailable or inapplicable.
    • jnxFruState—The current state of the FRU, whose object identifier is {jnxFruEntry 8}. The FRU state can be any of the following:
      • unknown(1)
      • empty(2)
      • present(3)
      • ready(4)
      • announceOnline(5)
      • online(6)
      • announceOffline(7)
      • offline(8)
      • diagnostic(9)
      • standby(10)
    • jnxFruTemp—The temperature of the FRU, in degrees Celsius, whose object identifier is {jnxFruEntry 9}. The value is zero if unavailable or inapplicable.
    • jnxFruOfflineReason—The reason the FRU is offline, whose object identifier is {jnxFruEntry 10}. The reason is represented by the following values:
      • unknown(1)—Unknown or other
      • none(2)—None
      • error(3)—Error
      • noPower(4)—No power
      • configPowerOff(5)—Configured to power off
      • configHoldInReset(6)—Configured to hold in reset
      • cliCommand(7)—Brought offline by a command-line interface (CLI) command
      • buttonPress(8)—Brought offline by button press
      • cliRestart(9)—Restarted by CLI command
      • overtempShutdown(10)—Overtemperature shutdown
      • masterClockDown(11)—Master clock down
      • singleSfmModeChange(12)—Single SFM mode change
      • packetSchedulingModeChange(13)—Packet scheduling mode change
      • physicalRemoval(14)—Physical removal
      • unresponsiveRestart(15)—Restarting unresponsive board
      • sonetClockAbsent(16)—SONET out clock absent
    • jnxFruLastPowerOff—The value of sysUpTime when this subject was last powered off, whose object identifier is {jnxFruEntry 11}. The value is zero if unavailable or inapplicable.
    • jnxFruLastPowerOn—The value of sysUpTime when this subject was last powered on, whose object identifier is {jnxFruEntry 12}. The value is zero if unavailable or inapplicable.
    • jnxFruPowerUpTime—The time interval in 10-millisecond periods that this subject has been up and running since the last power-on time, whose object identifier is {jnxFruEntry 13}. The value is zero if unavailable or inapplicable.
    • jnxFruChassisId—The chassis type of this subject. The object identifier for this object is {jnxFruEntry 14}.
    • jnxFruChassisDescr—The textual description for the chassis type of this subject. The object identifier is {jnxFruEntry 15}.
    • jnxFruPsdAssignment—The protected system domain (PSD) assignment for this subject. The object identifier is {jnxFruEntry 16}.

    Table 29 through Table 34 provide examples of jnxFruEntry objects. The following column headings for each table are abbreviated to correspond to the parts of the jnxFruEntry objects:

    • Contents index—jnxFruContentsIndex
    • L1—jnxFruL1Index
    • L2—jnxFruL2Index
    • L3—jnxFruL3Index
    • Name—jnxFruName
    • Type—jnxFruType
    • Slot—jnxFruSlot
    • State—jnxFruState
    • Temp—jnxFruTemp
    • Offline—jnxFruOffline
    • PowerOff—jnxFruPowerOff
    • PowerOn—jnxFruPowerOn
    • Uptime—jnxFruPowerUpTime

    Table 29 provides an example of jnxFruEntry objects in the jnxFruTable of an M10 router.

    Table 29: jnxFruContents Objects in the jnxFruTable of an M10 Router

    Index

    L1

    L2

    L3

    Name

    Type

    Slot

    State

    Temp

    Offline

    PowerOff

    PowerOn

    Uptime

    2

    1

    0

    0

    Power supply A

    powerEntryModule

    1

    Online

    0

    None

    0:0:00:00.00

    0:0:11:08.73

    264319

    2

    2

    0

    0

    Power supply B

    powerEntryModule

    2

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    4

    1

    1

    0

    Left fan 1

    fan

    1

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    4

    1

    2

    0

    Left fan 2

    fan

    1

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    4

    1

    3

    0

    Left fan 3

    fan

    1

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    4

    1

    4

    0

    Left fan 4

    fan

    1

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    6

    1

    0

    0

    FEB Internet Processor II

    controlBoard

    1

    Online

    24

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    7

    1

    0

    0

    FPC @ 0/*/*

    flexiblePicConcentrator

    1

    Online

    24

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    7

    2

    0

    0

    FPC @ 1/*/*

    flexiblePicConcentrator

    2

    Online

    24

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    1

    1

    0

    PIC: @ 0/0/*

    portInterfaceCard

    1

    Ready

    24

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    1

    2

    0

    PIC: 1x Monitor @ 0/1/*

    portInterfaceCard

    1

    Ready

    24

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    1

    3

    0

    PIC: 1x OC-12 ATM, MM @ 0/2/*

    portInterfaceCard

    1

    Ready

    24

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    1

    4

    0

    PIC: 4x T3 @ 0/3/*

    portInterfaceCard

    1

    Ready

    24

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    2

    1

    0

    PIC: 4x OC-3 SONET, SMIR @ 1/0/*

    portInterfaceCard

    2

    Ready

    24

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    2

    2

    0

    PIC: 4x OC-3 SONET, MM @ 1/1/*

    portInterfaceCard

    2

    Ready

    24

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    2

    3

    0

    PIC: 2x OC-3 ATM, MM @ 1/2/*

    portInterfaceCard

    2

    Ready

    24

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    2

    4

    0

    PIC: 2x OC-3 ATM, MM @ 1/3/*

    portInterfaceCard

    2

    Ready

    24

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    9

    1

    0

    0

    Routing Engine

    routingEngine

    1

    Online

    27

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    To verify the L1, L2, and L3 indexes, use the show chassis hardware command. Sample command output from an M10 router is as follows:.

    user@host> show chassis hardware
    Hardware inventory:
    Item             Version  Part number  Serial number     Description
    Chassis                                58974             M10
    Midplane         REV 03   710-001950   HB1590
    Power Supply A   Rev 03   740-002498   LK33505           DC
    Display          REV 04   710-001995   HE8442
    Routing Engine   REV 01   740-003239   9001025728        RE-2.0
    FEB              REV 12   710-001948   HA4221            Internet Processor II
    FPC 0
      PIC 1          REV 01   750-004188   AR2912            1x Monitor
      PIC 2          REV 04   750-001551   AN7869            1x OC-12 ATM, MM
      PIC 3          REV 02   750-002485   AN2803            4x T3
    FPC 1
      PIC 0          REV 03   750-002970   HF2293            4x OC-3 SONET, SMIR
      PIC 1          REV 03   750-002971   HA8094            4x OC-3 SONET, MM
      PIC 2          REV 03   750-002977   HD9352            2x OC-3 ATM, MM
      PIC 3          REV 03   750-002977   HD9393            2x OC-3 ATM, MM
    

    To verify FPC status, use the show chassis fpc command. Sample command output from an M10 router is as follows:

    user@host> show chassis fpc
    Temp  CPU Utilization (%)   Memory    Utilization (%)
    Slot State            (C)  Total  Interrupt      DRAM (MB) Heap     Buffer
      0  Online            24      3          1        64        44         17
      1  Online            24      3          1        64        44         17
    

    To verify Routing Engine status, use the show chassis routing-engine command. Sample command output from an M10 router is as follows:

    user@host> show chassis routing-engine
    Routing Engine status:
        Temperature                 26 degrees C / 78 degrees F
        DRAM                       768 MB
        Memory utilization           9 percent
        CPU utilization:
          User                       0 percent
          Background                 0 percent
          Kernel                     0 percent
          Interrupt                  0 percent
          Idle                     100 percent
        Model                          RE-2.0
        Serial ID                      b7000007c81ce801
        Start time                     2002-06-21 09:33:45 PDT
        Uptime                         3 days, 1 hour, 23 minutes, 27 seconds
        Load averages:                 1 minute   5 minute  15 minute
                                           0.07       0.03       0.01
    

    To verify FEB status, use the show chassis feb command. Sample command output from an M10 router is as follows:

    user@host> show chassis feb
    FEB status:
      Temperature                 24 degrees C / 75 degrees F
      CPU utilization              3 percent
      Interrupt utilization        1 percent
      Heap utilization            17 percent
      Buffer utilization          44 percent
      Total CPU DRAM              64 MB
      Internet Processor II        Version 1, Foundry IBM, Part number 9
      Start time:       2002-06-21 09:45:46 PDT
      Uptime:       3 days, 1 hour, 11 minutes, 33 seconds
    

    Table 30 provides an example of jnxFruEntry objects in the jnxFruTable of an M20 router.

    Table 30: JnxFruContents Objects in the jnxFruTable of an M20 Router

    Index

    L1

    L2

    L3

    Name

    Type

    Slot

    State

    Temp

    Offline

    PowerOff

    PowerOn

    Uptime

    2

    1

    0

    0

    Power supply A

    powerEntryModule

    1

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    2

    2

    0

    0

    Power supply B

    powerEntryModule

    2

    Online

    25

    None

    0:0:00:00.00

    0:0:00:43.45

    24993357

    4

    1

    0

    0

    Rear fan

    fan

    1

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    4

    2

    0

    0

    Front upper fan

    fan

    2

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    4

    3

    0

    0

    Front middle fan

    fan

    3

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    4

    4

    0

    0

    Front bottom fan

    fan

    4

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    6

    1

    0

    0

    SSB 0

    controlBoard

    1

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    6

    2

    0

    0

    SSB 1 Internet Processor I

    controlBoard

    2

    Online

    29

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    7

    1

    0

    0

    FPC @ 0/*/*

    flexible PicConcentrator

    1

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    7

    2

    0

    0

    FPC @ 1/*/*

    flexible PicConcentrator-

    2

    Online

    27

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    7

    3

    0

    0

    FPC @ 2/*/*

    flexible PicConcentrator

    3

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    7

    4

    0

    0

    FPC @ 3/*/*

    flexible PicConcentrator

    4

    Online

    27

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    1

    1

    0

    PIC: @ 0/0/*

    portInterfaceCard

    1

    Offline

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    1

    2

    0

    PIC: @ 0/1/*

    portInterfaceCard

    1

    Offline

    28

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    1

    3

    0

    PIC: @ 0/2/*

    portInterfaceCard

    1

    Offline

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    1

    4

    0

    PIC: @ 0/3/*

    portInterfaceCard

    1

    Offline

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    2

    1

    0

    PIC: 1x Tunnel @ 1/0/*

    portInterfaceCard

    2

    Ready

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    2

    2

    0

    PIC: 4x T3 @ 1/1/*

    portInterfaceCard

    2

    Ready

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    2

    3

    0

    PIC: 2x OC-3 ATM, MM @ 1/2/*

    portInterfaceCard

    2

    Ready

    27

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    2

    4

    0

    PIC: 1x G/E, 1000Base-SX @ 1/3/*

    portInterfaceCard

    2

    Ready

    27

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    3

    1

    0

    PIC: @ 2/0/*

    portInterfaceCard

    3

    Offline

    27

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    3

    2

    0

    PIC: @ 2/1/*

    portInterfaceCard

    3

    Offline

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    3

    3

    0

    PIC: @ 2/2/*

    portInterfaceCard

    3

    Offline

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    3

    4

    0

    PIC: @ 2/3/*

    portInterfaceCard

    3

    Offline

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    4

    1

    0

    PIC: @ 3/0/*

    portInterfaceCard

    4

    Ready

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    4

    2

    0

    PIC: @ 3/1/*

    portInterfaceCard

    4

    Ready

    28

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    4

    3

    0

    PIC: 2x OC-3 SONET, SMIR @ 3/2/*

    portInterfaceCard

    4

    Ready

    28

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    4

    4

    0

    PIC: @ 3/3/*

    portInterfaceCard

    4

    Ready

    28

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    9

    1

    0

    0

    Routing Engine 0

    routingEngine

    1

    Online

    25

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    9

    2

    0

    0

    Routing Engine 1

    routingEngine

    2

    Online

    24

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    10

    1

    0

    0

    Front panel display

    frontPanelModule

    1

    Online

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    To verify the L1, L2, and L3 indexes, use the show chassis hardware command. Sample command output from an M20 router is as follows:

    user@host> show chassis hardware
    Hardware inventory:
    Item             Version  Part number  Serial number     Description
    Chassis                                20200             M20
    Backplane        REV 07   710-001517   AB5911
    Power Supply B   Rev 02   7            000240            AC
    Display          REV 04   710-001519   AD1903
    Routing Engine 0 REV01    740          umeshk            RE-2.0
    Routing Engine 1                       270000078ba48501  RE-2.0
    SSB slot 0       N/A      N/A          N/A               backup
    SSB slot 1       REV 04   710-001411   AD0281            Internet Processor I
    FPC 1            REV 01   710-001292   AC9230
      PIC 0          REV 01   750-001323   AA2812            1x Tunnel
      PIC 1          REV 01   750-002963   AK8586            4x T3
      PIC 2          REV 03   750-000612   AM8116            2x OC-3 ATM, MM
      PIC 3          REV 08   750-001072   AB9884            1x G/E, 1000 BASE-SX
    FPC 3            REV 01   710-001197   AA8661
      PIC 2          REV 01   750-003748   HE9734            2x OC-3 SONET, SMIR
    
    user@host> show chassis environment
    Class Item                   Status     Measurement
    Power Power Supply A         Absent
          Power Supply B         OK         25 degrees C / 77 degrees F
    Temp  FPC 1                  OK         27 degrees C / 80 degrees F
          FPC 3                  OK         28 degrees C / 82 degrees F
          SSB 1                  OK         29 degrees C / 84 degrees F
          Backplane              OK         23 degrees C / 73 degrees F
          Routing Engine 0       OK         25 degrees C / 77 degrees F
          Routing Engine 1       OK         24 degrees C / 75 degrees F
    Fans  Rear Fan               OK         Spinning at normal speed
          Front Upper Fan        OK         Spinning at normal speed
          Front Middle Fan       OK         Spinning at normal speed
          Front Bottom Fan       OK         Spinning at normal speed
    Misc  Craft Interface        OK
    
    user@host> show chassis fpc
                         Temp  CPU Utilization (%)   Memory    Utilization (%)
    Slot State            (C)  Total  Interrupt      DRAM (MB) Heap     Buffer
      0  Empty              0      0          0         0         0          0
      1  Online            27      8          7         8         9         14
      2  Empty              0      0          0         0         0          0
      3  Online            28      0          0         8         8         14
    

    To verify Routing Engine status, use the show chassis routing-engine command. Sample command output from an M10 router is as follows:

    user@host> show chassis routing-engine
    Routing Engine status:
      Slot 0:
        Current state                  Master
        Election priority              Master (default)
        Temperature                 25 degrees C / 77 degrees F
        DRAM                       768 MB
        Memory utilization           8 percent
        CPU utilization:
          User                       0 percent
          Background                 0 percent
          Kernel                     1 percent
          Interrupt                  0 percent
          Idle                      99 percent
        Model                          RE-2.0
        Serial ID                      ba0000061779d601
        Start time                     2002-06-21 15:37:36 PDT
        Uptime                         2 days, 21 hours, 27 minutes, 25 seconds
        Load averages:                 1 minute   5 minute  15 minute
                                           0.00       0.00       0.00
    Routing Engine status:
      Slot 1:
        Current state                  Backup
        Election priority              Backup (default)
        Temperature                 24 degrees C / 75 degrees F
        DRAM                       768 MB
        Memory utilization           9 percent
        CPU utilization:
          User                       0 percent
          Background                 0 percent
          Kernel                     0 percent
          Interrupt                  0 percent
          Idle                      99 percent
        Model                          RE-2.0
        Serial ID                      270000078ba48501
        Start time                     2002-06-17 14:30:21 PDT
        Uptime                         6 days, 22 hours, 34 minutes, 28 seconds
    

    To verify SSB status, use the show chassis ssb command. Sample command output from an M10 router is as follows:

    user@host> show chassis ssb
    SSB status:
    Slot 0 information:
      State                          Backup
    Slot 1 information:
      State                          Master
      Temperature                 29 degrees C / 84 degrees F
      CPU utilization              1 percent
      Interrupt utilization        0 percent
      Heap utilization             8 percent
      Buffer utilization          43 percent
      Total CPU DRAM              64 MB
      Internet Processor I           Version 1, Foundry IBM, Part number 3
      Start time:                    2002-06-21 15:38:53 PDT
      Uptime:                        2 days, 21 hours, 26 minutes, 26 seconds
    

    Table 31 provides an example of jnxFruEntry objects in the jnxFruTable of an M160 router.

    Table 31: jnxFruContents Objects in the jnxFruTable of an M160 Router

    Index

    L1

    L2

    L3

    Name

    Type

    Slot

    State

    Temp

    Offline

    PowerOff

    PowerOn

    Uptime

    2

    1

    0

    0

    PEM 0

    powerEntryModule

    1

    Online

    0

    None

    0:00:00.00

    0:00:12.83

    6906955

    2

    2

    0

    0

    PEM 1

    powerEntryModule

    2

    Online

    0

    None

    0:00:00.00

    0:00:12.83

    6906955

    4

    1

    0

    0

    Front top blower

    fan

    1

    Present

    0

    None

    0:00:00.00

    0:00:00.00

    0

    4

    2

    1

    0

    Fan tray front left

    fan

    2

    Present

    0

    None

    0:00:00.00

    0:00:00.00

    0

    4

    2

    2

    0

    Fan tray front right

    fan

    2

    Present

    0

    None

    0:00:00.00

    0:00:00.00

    0

    4

    2

    3

    0

    Fan tray rear left

    fan

    2

    Present

    0

    None

    0:00:00.00

    0:00:00.00

    0

    4

    2

    4

    0

    Fan tray rear right

    fan

    2

    Present

    0

    None

    0:00:00.00

    0:00:00.00

    0

    4

    3

    0

    0

    Rear top blower

    fan

    3

    Present

    0

    None

    0:00:00.00

    0:00:00.00

    0

    4

    4

    0

    0

    Rear bottom blower

    fan

    4

    Present

    0

    None

    0:00:00.00

    0:00:00.00

    0

    6

    1

    1

    0

    SFM 0 SPP

    switchingAnd ForwardingMode

    1

    Online

    35

    None

    0:00:03.13

    0:00:00.00

    0

    6

    1

    2

    0

    SFM 0 SPR Internet Processor II

    switchingAnd ForwardingMode

    1

    Online

    35

    None

    0:00:03.13

    0:00:00.00

    0

    6

    2

    1

    0

    SFM 1 SPP

    switchingAnd ForwardingMode

    2

    Empty

    0

    None

    0:00:00.00

    0:00:00.00

    0

    6

    2

    2

    0

    SFM 1 SPR

    switchingAnd ForwardingMode

    2

    Empty

    0

    None

    0:00:00.00

    0:00:00.00

    0

    6

    3

    1

    0

    SFM 2 SPP

    switchingAnd ForwardingMode

    3

    Online

    44

    None

    0:00:03.20

     

    0:00:00.00

    0

    6

    3

    2

    0

    SFM 2 SPR Internet Processor II

    switchingAnd ForwardingMode

    3

    Online

    44

    None

    0:00:03.20

     

    0:00:00.00

    0

    6

    4

    1

    0

    SFM 3 SPP

    switchingAnd ForwardingMode

    4

    Offline

    0

    Config- ured to power off

    0:00:03.22

     

    0:00:00.00

    0

    6

    4

    2

    0

    SFM 3 SPR

    switchingAnd ForwardingMode

    4

    Offline

    0

    Config- ured to power off

    0:00:03.22

    0:00:00.00

    0

    7

    1

    0

    0

    FPC @ 0/*/*

    flexiblePic Concentrator

    1

    Offline

    0

    Config- ured to power off

    0:00:02.28

    0:00:00.00

    0

    7

    2

    0

    0

    FPC @ 1/*/*

    flexiblePic Concentrator

    2

    Offline

    0

    Error

    0:13:08.12

    0:00:00.00

    0

    7

    3

    0

    0

    FPC @ 2/*/*

    flexiblePic Concentrator

    3

    Online

     

    30

    None

    0:00:02.32

    0:00:00.00

    0

    7

    4

    0

    0

    FPC: 1x OC-192 SM LR @ 3/*/*

    flexiblePic Concentrator

    4

    Online

    41

    None

    0:00:02.34

     

    0:00:00.00

    0

    7

    5

    0

    0

    FPC @ 4/*/*

    flexiblePic Concentrator

    5

    Empty

    0

    None

    0:00:00.00

    0:00:00.00

    0

    7

    6

    0

    0

    FPC @ 5/*/*

    flexiblePic Concentrator

    6

    Offline

    0

    Config ured to power off

    0:00:02.37

     

    0:00:00.00

    0

    7

    7

    0

    0

    FPC @ 6/*/*

    flexiblePic Concentrator

    7

    Empty

    0

    None

    0:00:00.00

    0:00:00.00

    0

    7

    8

    0

    0

    FPC @ 7/*/*

    flexiblePic Concentrator

    8

    Online

    41

    None

    0:00:03.11

    0:00:00.00

    0

    8

    1

    1

    0

    PIC: @ 0/0/*

    portInterfaceCard

    1

    Online

    40

    None

    0:00:00.00

    0:00:00.00

    0

    8

    1

    2

    0

    PIC: @ 0/1/*

    portInterface Card

    1

    Online

    40

    None

    0:00:00.00

    0:00:00.00

    0

    8

    1

    3

    0

    PIC: @ 0/2/*

    portInterfaceCard

    1

    Online

    40

    None

    0:00:00.00

    0:00:00.00

    0

    8

    1

    4

    0

    PIC: @ 0/3/*

    portInterfaceCard

    1

    Online

    40

    None

    0:00:00.00

    0:00:00.00

    0

    8

    2

    1

    0

    PIC: @ 1/0/*

    portInterfaceCard

    2

    Online

    46

    None

    0:00:00.00

    0:00:00.00

    0

    8

    2

    2

    0

    PIC: @ 1/1/*

    portInterfaceCard

    2

    Online

    46

    None

    0:00:00.00

    0:00:00.00

    0

    8

    2

    3

    0

    PIC: @ 1/2/*

    portInterfaceCard

    2

    Online

    46

    None

    0:00:00.00

    0:00:00.00

    0

    8

    2

    4

    0

    PIC: @ 1/3/*

    portInterfaceCard

    2

    Online

    46

    None

    0:00:00.00

    0:00:00.00

    0

    8

    3

    1

    0

    PIC: @ 2/0/*

    portInterfaceCard

    3

    Offline

    0

    Config- ured to power off

    0:00:02.28

    0:00:00.00

    0

    8

    3

    2

    0

    PIC: @ 2/1/*

    portInterfaceCard

    3

    Offline

    0

    Config- ured to power off

    0:00:02.28

    0:00:00.00

    0

    8

    3

    3

    0

    PIC: @ 2/2/*

    portInterfaceCard

    3

    Offline

    0

    Config ured to power off

    0:00:02.28

    0:00:00.00

    0

    8

    3

    4

    0

    PIC: @ 2/3/*

    portInterfaceCard

    3

    Offline

    0

    Config- ured to power off

    0:00:02.28

    0:00:00.00

    0

    8

    4

    1

    0

    PIC: 1x OC-192 SM LR @ 3/0/*

    portInterfaceCard

    4

    Offline

    0

    Error

    0:13:08.12

    0:00:00.00

    0

    8

    4

    2

    0

    PIC continued

    portInterfaceCard

    4

    Offline

    0

    Error

    0:13:08.12

    0:00:00.00

    0

    8

    4

    3

    0

    PIC continued

    portInterfaceCard

    4

    Offline

    0

    Error

    0:13:08.12

    0:00:00.00

    0

    8

    4

    4

    0

    PIC continued

    portInterfaceCard

    4

    Offline

    0

    Error

    0:13:08.12

    0:00:00.00

    0

    8

    5

    1

    0

    PIC: @ 4/0/*

    portInterfaceCard

    5

    Online

    30

    None

    0:00:02.32

    0:00:00.00

    0

    8

    5

    2

    0

    PIC: @ 4/1/*

    portInterfaceCard

    5

    Online

    30

    None

    0:00:02.32

    0:00:00.00

    0

    8

    5

    3

    0

    PIC: @ 4/2/*

    portInterfaceCard

    5

    Online

    30

    None

    0:00:02.32

    0:00:00.00

    0

    8

    5

    4

    0

    PIC: @ 4/3/*

    portInterfaceCard

    5

    Online

    30

    None

    0:00:02.32

    0:00:00.00

    0

    8

    6

    1

    0

    PIC: @ 5/0/*

    portInterfaceCard

    6

    Online

    41

    None

    0:00:02.34

    0:00:00.00

    0

    8

    6

    2

    0

    PIC: @ 5/1/*

    portInterfaceCard

    6

    Online

    41

    None

    0:00:02.34

    0:00:00.00

    0

    8

    6

    3

    0

    PIC: @ 5/2/*

    portInterfaceCard

    6

    Online

    41

    None

    0:00:02.34

    0:00:00.00

    0

    8

    6

    4

    0

    PIC: @ 5/3/*

    portInterfaceCard

    6

    Online

    41

    None

    0:00:02.34

    0:00:00.00

    0

    8

    7

    1

    0

    PIC: @ 6/0/*

    portInterfaceCard

    7

    Empty

    0

    None

    0:00:00.00

    0:00:00.00

    0

    8

    7

    2

    0

    PIC: @ 6/1/*

    portInterfaceCard

    7

    Empty

    0

    None

    0:00:00.00

    0:00:00.00

    0

    8

    7

    3

    0

    PIC: @ 6/2/*

    portInterfaceCard (11)

    7

    Empty

    0

    None

    0:00:00.00

    0:00:00.00

    0

    8

    7

    4

    0

    PIC: @ 6/3/*

    portInterfaceCard (11)

    7

    Empty

    0

    None

    0:00:00.00

    0:00:00.00

    0

    8

    8

    1

    0

    PIC: 1x OC-12 SONET, SMIR @ 7/0/*

    portInterfaceCard

    8

    Offline

     

    0

    Config- ured to power off

    0:00:02.37

     

    0:00:00.00

    0

    8

    8

    2

    0

    PIC: 4x E3 @ 7/1/*

    portInterfaceCard

    8

    Offline

     

    0

    Config- ured to power off

    0:00:02.37

     

    0:00:00.00

    0

    8

    8

    3

    0

    PIC: 1x OC-12 SONET, MM @ 7/2/*

    jnxFruName

    portInterfaceCard

    8

    Offline

     

    0

    Config- ured to power off

    0:00:02.37

    0:00:00.00

    0

    8

    8

    4

    0

    PIC: @ 7/3/*

    portInterfaceCard

    8

    Offline

    0

    Config- ured to power off

    0:00:02.37

     

    0:00:00.00

    0

    9

    1

    0

    0

    Routing Engine 0

    routingEngine

    1

    Online

    31

    None

    0:00:00.00

    0:00:00.00

    0

    9

    2

    0

    0

    Routing Engine 1

    routingEngine

    2

    Present

    0

    None

    0:00:00.00

    0:00:00.00

    0

    10

    1

    1

    0

    FPM CMB

    frontPanelModule

    1

    Online

    28

    None

    0:00:00.00

    0:00:00.00

    0

    10

    1

    2

    0

    FPM Display

    frontPanelModule

    1

    Online

    28

    None

    0:00:00.00

    0:00:00.00

    0

    11

    1

    0

    0

    PCG 0

    clockGenerator

    1

    Online

    40

    None

    0:00:00.00

    0:00:00.00

    0

    11

    2

    0

    0

    PCG 1

    clockGenerator

    2

    Online

    46

    None

    0:00:00.00

    0:00:00.00

    0

    12

    1

    0

    0

    MCS 0

    controlBoard

    1

    Online

    47

    None

    0:00:00.00

    0:00:00.00

    0

    12

    2

    0

    0

    MCS 1

    controlBoard

    2

    Empty

    0

    None

    0:00:00.00

    0:00:00.00

    0

    13

    1

    0

    0

    CIP

    craftInterfacePanel-

    1

    Present

    0

    None

    0:00:00.00

    0:00:00.00

    0

    To verify the L1, L2, and L3 indexes, use the show chassis hardware command. Sample command output from an M160 router is as follows:

    user@host> show chassis hardware
    Hardware inventory:
    Item             Version  Part number  Serial number     Description
    Chassis                                47                M160
    Midplane         REV 02   710-001245   AB4113
    FPM CMB          REV 01   710-001642   AA9721
    FPM Display      REV 01   710-001647   AA2995
    CIP              REV 02   710-001593   AA9886
    PEM 0            Rev 01   740-001243   KJ35782           DC
    PEM 1            Rev 01   740-001243   kj35756           DC
    PCG 0            REV 01   710-001568   AA9796
    PCG 1            REV 01   710-001568   AA9895
    Routing Engine 0 REV01    740-003239   AARCHOO           RE-2.0
    Routing Engine 1
    MCS 0            REV 03   710-001226   AA9779
    SFM 0 SPP        REV 07   710-001228   AE5504
    SFM 0 SPR        REV 03   710-002189   AE4707            Internet Processor II
    SFM 2 SPP        REV 06   710-001228   AB3133
    SFM 2 SPR        REV 01   710-002189   AB2941            Internet Processor II
    SFM 3 SPP        REV 07   710-001228   AV3167
    SFM 3 SPR        REV 04   710-002189   AV3439            Internet Processor II
    FPC 0            REV 02   710-001611   AA9518            FPC Type 2
      CPU            REV 02   710-001217   AA9572
    FPC 1            REV 03   710-001255   AA9812            FPC Type 1
      CPU
    FPC 2            REV 02   710-001611   AA9527            FPC Type 2
      CPU            REV 02   710-001217   AA9592
    FPC 3            REV 01   710-003061   HB2029            FPC Type OC192
      CPU            REV 05   710-001217   AF5950
      PIC 0          REV 01   750-003063   HB2029            1x OC-192 SM LR
    FPC 5            REV 01   710-001255   AA2914            FPC Type 1
      CPU            REV 02   710-001217   AA2893
    FPC 7            REV 03   710-001255   AA9809            FPC Type 1
      CPU            REV 02   710-001217   AA9573
      PIC 0          REV 04   750-000613   AA0374            1x OC-12 SONET, SMIR
      PIC 1          REV 02   750-E3-PIC   AC1903            4x E3
      PIC 2          REV 02   750-001020   AA8944            1x OC-12 SONET, MM
    

    To verify FPC status, use the show chassis fpc command. Sample command output from an M160 router is as follows:

    user@host> show chassis fpc
    Temp  CPU Utilization (%)   Memory    Utilization (%)
    Slot State            (C)  Total  Interrupt      DRAM (MB) Heap     Buffer
      0  Announce offline   0      0          0         0         0          0
      1  Present            0      0          0         0         0          0
      2  Online            32      4          0        32         1         39
      3  Online            44      1          0        32         1         40
      4  Empty              0      0          0         0         0          0
      5  Offline         --- Chassis connection dropped ---
      6  Empty              0      0          0         0         0          0
      7  Online            42      4          0        32         1         40
    

    To verify Routing Engine status, use the show chassis routing-engine command. Sample command output from an M160 router is as follows:

    user@host> show chassis routing-engine
    Routing Engine status:
      Slot 0:
        Current state                  Master
        Election priority              Master (default)
        Temperature                 35 degrees C / 95 degrees F
        DRAM                       768 MB
        Memory utilization          10 percent
        CPU utilization:
          User                       1 percent
          Background                 0 percent
          Kernel                    10 percent
          Interrupt                  3 percent
          Idle                      87 percent
        Model                          RE-2.0
        Serial ID                      0c000004f8d26401
        Start time                     2002-06-14 14:39:03 PDT
        Uptime                         11 minutes, 46 seconds
        Load averages:                 1 minute   5 minute  15 minute
                                           0.18       0.19       0.14
    Routing Engine status:
      Slot 1:
        Current state                  Present
    

    To verify SFM status, use the show chassis sfm command. Sample command output from an M160 router is as follows:

    user@host> show chassis sfm
    Temp  CPU Utilization (%)   Memory    Utilization (%)
    Slot State            (C)  Total  Interrupt      DRAM (MB) Heap     Buffer
      0  Online            35      1          0        64        16         46
      1  Empty              0      0          0         0         0          0
      2  Online            47      1          0        64        16         45
      3  Online            50      1          0        64        16         45
    Packet scheduling mode : Disabled
    

    Table 32 provides an example of jnxFruEntry objects in the jnxFruTable of an M40 router.

    Table 32: jnxFruContents Objects in the jnxFruTable of an M40 Router

    Index

    L1

    L2

    L3

    Name

    Type

    Slot

    State

    Temp

    Offline

    PowerOff

    PowerOn

    Uptime

    2

    1

    0

    0

    Power supply A

    powerEntry Module

    1

    Online

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    101974

    2

    2

    0

    0

    Power supply B

    powerEntry Module

    2

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    3

    1

    0

    0

    Top impeller

    fan

    1

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    3

    2

    0

    0

    Bottom impeller

    fan

    2

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    4

    1

    0

    0

    Rear left fan

    fan

    1

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    4

    2

    0

    0

    Rear center fan

    fan

    2

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    4

    3

    0

    0

    Rear right fan

    fan

    3

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    5

    1

    0

    0

    Host controller

    routingEngine

    1

    Online

    37

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    6

    1

    0

    0

    SCB Internet Processor I

    controlBoard

    1

    Online

    27

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    7

    1

    0

    0

    FPC @ 0/*/*

    flexiblePic Concentrator

    1

    Online

    28

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    7

    2

    0

    0

    FPC @ 1/*/*

    flexible PicConcentrator

    2

    Online

    29

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    7

    3

    0

    0

    FPC @ 2/*/*

    flexible PicConcentrator

    3

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    7

    4

    0

    0

    FPC @ 3/*/*

    flexiblePic Concentrator

    4

    Online

    24

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    7

    5

    0

    0

    FPC @ 4/*/*

    flexiblePic Concentrator

    5

    Online

    27

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    7

    6

    0

    0

    FPC @ 5/*/*

    flexiblePic Concentrator

    6

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    7

    7

    0

    0

    FPC: 1x OC-48 SONET, SMIR @ 6/*/*

    flexiblePic Concentrator

    7

    Online

    28

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    7

    8

    0

    0

    FPC @ 7/*/*

    flexible PicConcentrator

    8

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    1

    1

    0

    PIC: 1x G/E, 1000Base-SX @ 0/0/*

    portInterfaceCard

    1

    Ready

    24

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    1

    2

    0

    PIC: 1x Tunnel @ 0/1/*

    portInterfaceCard

    1

    Ready

    24

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    1

    3

    0

    PIC: 4x T1, RJ48 @ 0/2/*

    portInterfaceCard

    1

    Ready

    24

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    1

    4

    0

    PIC: 1x COC12, SMIR @ 0/3/*

    portIntefaceCard

    1

    Ready

    24

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    2

    1

    0

    PIC: 2x OC-3 ATM, MM @ 1/0/*

    portInterfaceCard

    2

    Ready

    27

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    2

    2

    0

    PIC: 4x OC-3 SONET, MM @ 1/1/*

    portInterfaceCard

    2

    Ready

    27

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    2

    3

    0

    PIC: 2x T3 @ 1/2/*

    portInterfaceCard

    2

    Ready

    27

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    2

    4

    0

    PIC: 1x CSTM1, SMIR @ 1/3/*

    portInterfaceCard

    2

    Ready

    27

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    3

    1

    0

    PIC: @ 2/0/*

    portInterfaceCard

    3

    Offline

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    3

    2

    0

    PIC: @ 2/1/*

    portInterfaceCard

    3

    Offline

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    3

    3

    0

    PIC: @ 2/2/*

    portInterfaceCard

    3

    Offline

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    3

    4

    0

    PIC: @ 2/3/*

    portInterfaceCard

    3

    Offline

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    4

    1

    0

    PIC: @ 3/0/*

    portInterfaceCard

    4

    Ready

    24

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    4

    2

    0

    PIC: 4x F/E, 100 BASE-TX @ 3/1/*

    portInterfaceCard

    4

    Ready

    24

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    4

    3

    0

    PIC: 1x 800M Crypto @ 3/2/*

    portInterfaceCard

    4

    Ready

    24

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    4

    4

    0

    PIC: 1x CT3-NxDS0 @ 3/3/*

    portInterfaceCard

    4

    Ready

    24

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    5

    1

    0

    PIC: @ 4/0/*

    portInterfaceCard

    5

    Ready

    27

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    5

    2

    0

    PIC: @ 4/1/*

    portInterfaceCard

    5

    Ready

    27

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    5

    3

    0

    PIC: @ 4/2/*

    portInterfaceCard

    5

    Ready

    27

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    5

    4

    0

    PIC: @ 4/3/*

    flexible PicConcentrator

    5

    Ready

    27

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    6

    1

    0

    PIC: @ 5/0/*

    portInterfaceCard

    6

    Offline

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    6

    2

    0

    PIC: @ 5/1/*

    portInterfaceCard

    6

    Offline

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    6

    3

    0

    PIC: @ 5/2/*

    portInterfaceCard

    6

    Offline

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    6

    4

    0

    PIC: @ 5/3/*

    portInterfaceCard

    6

    Offline

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    7

    1

    0

    PIC: 1x OC-48 SONET, SMIR @ 6/0/*

    portInterfaceCard

    7

    Ready

    28

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    7

    2

    0

    PIC continued

    portInterfaceCard

    7

    Ready

    28

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    7

    3

    0

    PIC continued

    portInterfaceCard

    7

    Ready

    28

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    7

    4

    0

    PIC continued

    portInterfaceCard

    7

    Ready

    28

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    8

    1

    0

    PIC: @ 7/0/*

    portInterfaceCard

    8

    Offline

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    8

    2

    0

    PIC: @ 7/1/*

    portInterfaceCard

    8

    Offline

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    8

    3

    0

    PIC: @ 7/2/*

    portInterfaceCard

    8

    Offline

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    8

    4

    0

    PIC: @ 7/3/*

    portInterfaceCard

    8

    Offline

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    9

    1

    0

    0

    Routing Engine

    routingEngine

    1

    Online

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    To verify the L1, L2, and L3 indexes, use the show chassis hardware command. Sample command output from an M40 router is as follows:

    user@host> show chassis hardware
    Hardware inventory:
    Item             Version  Part number  Serial number     Description
    Chassis
    Backplane        REV 03   710-000073   AA2005
    Power Supply A   Rev A    740-000235   000119            DC
    Maxicab          REV 04   710-000229   AA0691
    Minicab          REV 02   710-000482   AA0270
    Display          REV 06   710-000150   AA1042
    Routing Engine                                           RE-1.0
    SCB              REV 07   710-000075   AA1033            Internet Processor I
    FPC 0            REV 01   710-001292   AB8159
      PIC 0          REV 08   750-001072   AP5525            1x G/E, 1000 BASE-SX
      PIC 1          REV 01   750-001323   AB1645            1x Tunnel
      PIC 2          REV 01   750-002953   AD9083            4x T1, RJ48
      PIC 3          REV 03   750-001190   AE2907            1x COC12, SMIR
    FPC 1            REV 10   710-000175   AA7219
      PIC 0          REV 03   750-002977   HD9331            2x OC-3 ATM, MM
      PIC 1          REV 04   750-002971   HC8020            4x OC-3 SONET, MM
      PIC 2          REV 02.1 710-000608   AA1592            2x T3
      PIC 3          REV 05   750-003248   AD9648            1x CSTM1, SMIR
    FPC 3            REV 10   710-000175   AA4782
      PIC 1          REV 04   750-002992   HC3974            4x F/E, 100 BASE-TX
      PIC 2          REV 03   750-003844   AY4806            1x 800M Crypto
      PIC 3          REV 03   750-004743   BD9433            1x CT3-NxDS0
    FPC 4            REV 01   710-001292   AC5265
    FPC 6            REV 01   710-001292   AB7485
      PIC 0          REV 03   750-000617   AA4566            1x OC-48 SONET, SMIR
    
    user@host> show chassis environment
    Class Item                   Status     Measurement
    Power Power Supply A         OK
          Power Supply B         Absent
    Temp  FPC 0                  OK         28 degrees C / 82 degrees F
          FPC 1                  OK         29 degrees C / 84 degrees F
          FPC 3                  OK         24 degrees C / 75 degrees F
          FPC 4                  OK         27 degrees C / 80 degrees F
          FPC 6                  OK         28 degrees C / 82 degrees F
          SCB                    OK         27 degrees C / 80 degrees F
          Backplane @ A1         OK         30 degrees C / 86 degrees F
          Backplane @ A2         OK         26 degrees C / 78 degrees F
          Routing Engine         OK         37 degrees C / 98 degrees F
    Fans  Top Impeller           OK         Spinning at normal speed
          Bottom impeller        OK         Spinning at normal speed
          Rear Left Fan          OK         Spinning at normal speed
          Rear Center Fan        OK         Spinning at normal speed
          Rear Right Fan         OK         Spinning at normal speed
    Misc  Craft Interface        OK
    

    To verify FPC status, use the show chassis fpc command. Sample command output from an M40 router is as follows:

    user@host> show chassis fpc
    Temp  CPU Utilization (%)   Memory    Utilization (%)
    Slot State            (C)  Total  Interrupt      DRAM (MB) Heap     Buffer
      0  Online            28      2          0         8        11         14
      1  Online            29      7          0         8        21         14
      2  Empty              0      0          0         0         0          0
      3  Online            24     17          0         8        22         15
      4  Online            27      1          0         8         6         13
      5  Empty              0      0          0         0         0          0
      6  Online            28      1          0         8         7         15
      7  Empty              0      0          0         0         0          0
    

    To verify Routing Engine status, use the show chassis routing-engine command. Sample command output from an M40 router is as follows:

    user@host> show chassis routing-engine
    Routing Engine status:
        Temperature                 37 degrees C / 98 degrees F
        DRAM                               256 MB
        Memory utilization          19 percent
        CPU utilization:
          User                       1 percent
          Background                 0 percent
          Kernel                     3 percent
          Interrupt                  1 percent
          Idle                         96 percent
        Model         RE-1.0
        Start time                     2002-06-24 17:28:30 UTC
        Uptime                         20 minutes, 30 seconds
        Load averages:                 1 minute   5 minute  15 minute
                                           0.00       0.04       0.11
    

    To verify SCB status, use the show chassis scb command. Sample command output from an M40 router is as follows:

    user@host> show chassis scb
    SCB status:
      Temperature                          27 degrees C / 80 degrees F
      CPU utilization                      3 percent
      Interrupt utilization                  0 percent
      Heap utilization          9 percent
      Buffer utilization          44 percent
      Total CPU DRAM                         64 MB
      Internet Processor I           Version 1, Foundry IBM, Part number 3
      Start time:                    2002-06-24 17:30:10 UTC
      Uptime:                        19 minutes, 8 seconds
    

    Table 33 provides an example of jnxFruEntry objects in the jnxFruTable of an M40e router.

    Table 33: jnxFruContents Objects in the jnxFruTable of an M40e Router

    Index

    L1

    L2

    L3

    Name

    Type

    Slot

    State

    Temp

    Offline

    PowerOff

    PowerOn

    Uptime

    2

    1

    0

    0

    PEM 0

    powerEntryModule

    1

    Present

    0

    None

    0:0:00:00.00

    0:0:00:25.99

    208927

    2

    2

     

    0

    PEM 1

    powerEntryModule

    2

    Online

    0

    None

    0:0:00:00.00

    0:0:00:25.99

    208928

    4

    1

    0

    0

    Front top blower

    fan

    1

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    4

    2

    1

    0

    Fan tray front left

    fan

    2

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    4

    2

    2

    0

    Fan tray front right

    fan

    2

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    4

    2

    3

    0

    Fan tray rear left

    fan

    2

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    4

    2

    4

    0

    Fan tray rear right

    fan

    2

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    4

    3

    0

    0

    Rear top blower

    fan

    3

    Present

     

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    4

    4

    0

    0

    Rear bottom blower

    fan

    4

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    6

    1

    1

    0

    SFM 0 SPP

    switchingAnd ForwardingModule

    1

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    6

    1

    2

    0

    SFM 0 SPR

    switchingAnd ForwardingModule

    1

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    6

    2

    1

    0

    SFM 1 SPP

    switchingAnd ForwardingModule

    2

    Online

    42

    None

    0:0:00:21.95

    0:0:00:00.00

    0

    6

    2

    2

    0

    SFM 1 SPR Internet Processor II

    switchingAnd ForwardingModule

    2

    Online

    42

    None

    0:0:00:21.95

    0:0:00:00.00

    0

    7

    1

    0

    0

    FPC @ 0/*/*

    flexiblePic Concentrator

    1

    Online

    41

    None

    0:0:00:21.85

    0:0:00:00.00

    0

    7

    2

    0

    0

    FPC @ 1/*/*

    flexible PicConcentrator

    2

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    7

    3

    0

    0

    FPC @ 2/*/*

    flexible PicConcentrator

    3

    Online

    43

    None

    0:0:00:21.87

    0:0:00:00.00

    0

    7

    4

    0

    0

    FPC @ 3/*/*

    flexible PicConcentrator

    4

    Online

    38

    None

    0:0:00:21.89

    0:0:00:00.00

    0

    7

    5

    0

    0

    FPC @ 4/*/*

    flexiblePic Concentrator

    5

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    7

    6

    0

    0

    FPC @ 5/*/*

    flexiblePic Concentrator

    6

    Online

    46

    None

    0:0:00:21.91

    0:0:00:00.00

    0

    7

    7

    0

    0

    FPC @ 6/*/*

    flexiblePic Concentrator

    7

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    7

    8

    0

    0

    FPC @ 7/*/*

    flexiblePic Concentrator

    8

    Online

    44

    None

    0:0:00:21.93

    0:0:00:00.00

    0

    8

    1

    1

    0

    PIC: @ 0/0/*

    portInterfaceCard

    1

    Online

    45

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    1

    2

    0

    PIC: 1x OC-12 SONET, MM @ 0/1/*

    portInterfaceCard

    1

    Online

    45

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    1

    3

    0

    PIC: 4x CT3 @ 0/2/*

    portInterfaceCard

    1

    Online

    45

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    1

    4

    0

    PIC: 1x Multi Link(32) @ 0/3/*

    portInterfaceCard

    1

    Online

    45

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    2

    1

    0

    PIC: @ 1/0/*

    portInterfaceCard

    2

    Online

    50

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    2

    2

    0

    PIC: @ 1/1/*

    portInterfaceCard

    2

    Online

    50

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    2

    3

    0

    PIC: @ 1/2/*

    portInterfaceCard

    2

    Online

    50

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    2

    4

    0

    PIC: @ 1/3/*

    portInterfaceCard

    2

    Online

    50

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    3

    1

    0

    PIC: 1x OC-12 SONET, MM @ 2/0/*

    portInterfaceCard

    3

    Online

    41

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    3

    2

    0

    PIC: 1x OC-12 SONET, MM @ 2/1/*

    portInterfaceCard

    3

    Online

    41

    None

    0:0:00:21.85

    0:0:00:00.00

    0

    8

    3

    3

    0

    PIC: 1x OC-12 SONET, MM @ 2/2/*

    portInterfaceCard

    3

    Online

    41

    0:0:00:21.85

    0:0:00:00.00

    8

    3

    4

    0

    PIC: @ 2/3/*

    portInterfaceCard

    3

    Online

    41

    0:0:00:21.85

    0:0:00:00.00

    8

    4

    1

    0

    PIC: 1x OC-48 SONET, SMIR @ 3/0/*

    portInterfaceCard

    4

    Empty

    0

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    4

    2

    0

    PIC: @ 3/1/*

    portInterfaceCard

    4

    Empty

    0

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    4

    3

    0

    PIC: @ 3/2/*

    portInterfaceCard

    4

    Empty

    0

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    4

    4

    0

    PIC: @ 3/3/*

    portInterfaceCard

    4

    Empty

    0

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    5

    1

    0

    PIC: @ 4/0/*

    portInterfaceCard

    5

    Online

    43

    0:0:00:21.87

    0:0:00:00.00

    0

    8

    5

    2

    0

    PIC: @ 4/1/*

    portInterfaceCard

    5

    Online

    43

    0:0:00:21.87

    0:0:00:00.00

    0

    8

    5

    3

    0

    PIC: @ 4/2/*

    portInterfaceCard

    5

    Online

    43

    0:0:00:21.87

    0:0:00:00.00

    0

    8

    5

    4

    0

    PIC: @ 4/3/*

    portInterfaceCard

    5

    Online

    43

    0:0:00:21.87

    0:0:00:00.00

    0

    8

    6

    1

    0

    PIC: @ 5/0/*

    portInterfaceCard

    6

    Online

    38

    0:0:00:21.89

    0:0:00:00.00

    0

    8

    6

    2

    0

    PIC: @ 5/1/*

    portInterfaceCard

    6

    Online

    38

    0:0:00:21.89

    0:0:00:00.00

    0

    8

    6

    3

    0

    PIC: 1x OC-12 SONET, SMIR @ 5/2/*

    portInterfaceCard

    6

    Online

    38

    0:0:00:21.89

    0:0:00:00.00

    0

    8

    6

    4

    0

    PIC: 1x OC-12 SONET, MM @ 5/3/*

    portInterfaceCard

    6

    Online

    38

    0:0:00:21.89

    0:0:00:00.00

    0

    8

    7

    1

    0

    PIC: @ 6/0/*

    portInterfaceCard

    7

    Empty

    0

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    7

    2

    0

    PIC: @ 6/1/*

    portInterfaceCard

    7

    Empty

    0

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    7

    3

    0

    PIC: @ 6/2/*

    portInterfaceCard

    7

    Empty

    0

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    7

    4

    0

    PIC: @ 6/3/*

    portInterfaceCard

    7

    Empty

    0

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    8

    1

    0

    PIC: 8x FE-FX, 100 BASE-FX @ 7/0/*

    portInterfaceCard

    8

    Online

    46

    0:0:00:21.91

    0:0:00:00.00

    0

    8

    8

    2

    0

    PIC: @ 7/1/*

    portInterfaceCard

    8

    Online

    46

    0:0:00:21.91

    0:0:00:00.00

    0

    8

    8

    3

    0

    PIC: 1x Link Service(4) @ 7/2/*

    portInterfaceCard

    8

    Online

    46

    0:0:00:21.91

    0:0:00:00.00

    0

    8

    8

    4

    0

    PIC: @ 7/3/*

    portInterfaceCard

    1

    Online

    46

    0:0:00:00.00

    0:0:00:00.00

    0

    9

    1

    0

    0

    Routing Engine 0

    routingEngine

    2

    Online

    46

    0:0:00:00.00

    0:0:00:00.00

    0

    9

    2

    0

    0

    Routing Engine 1

    routingEngine

    1

    Present

    34

    0:0:00:00.00

    0:0:00:00.00

    0

    10

    1

    1

    0

    FPM CMB

    frontPanelModule

    1

    Online

    28

    0:0:00:00.00

    0:0:00:00.00

    0

    10

    1

    2

    0

    FPM Display

    frontPanelModule

    1

    Online

    28

    0:0:00:00.00

    0:0:00:00.00

    0

    11

    1

    0

    0

    PCG 0

    clockGenerator

    1

    Online

    45

    0:0:00:00.00

    0:0:00:00.00

    0

    11

    2

    0

    0

    PCG 1

    clockGenerator

    2

    Online

    50

    0:0:00:00.00

    0:0:00:00.00

    0

    12

    1

    0

    0

    MCS 0

    controlBoard

    1

    Online

    46

    0:0:00:00.00

    0:0:00:00.00

    0

    12

    2

    0

    0

    MCS 1

    controlBoard

    2

    Online

    0

    0:0:00:00.00

    0:0:00:00.00

    0

    13

    1

    0

    0

    CIP

    craftInterfacePanel

    1

    Present

    0

    0:0:00:00.00

    0:0:00:00.00

    0

    To verify L1, L2, and L3 indexes, use the show chassis hardware command. The sample output from an M40e router is as follows:

    user@host> show chassis hardware
    Item             Version  Part number  Serial number     Description
    Chassis                                19084             M40e
    Midplane         REV 01   710-005071   AX3654
    FPM CMB          REV 03   710-001642   AR9037
    FPM Display      REV 03   710-001647   AP1334
    CIP              REV 08   710-001593   AE8486
    PEM 0            Rev 01   740-003787   ME13120           Power Entry Module
    PEM 1            Rev 01   740-003787   MC25354           Power Entry Module
    PCG 0            REV 07   710-001568   AG1377
    PCG 1            REV 07   710-001568   AR3806
    Routing Engine 0 REV 04   740-003239   9001026568        RE-2.0
    Routing Engine 1
    MCS 0            REV 11   710-001226   AN5810
    MCS 1            REV 11   710-001226   AR0109
    SFM 1 SPP        REV 07   710-001228   BE0106
    SFM 1 SPR        REV 05   710-002189   BE0062            Internet Processor II
    FPC 0            REV 01   710-005078   BE0642            M40e-FPC Type 1
      CPU            REV 01   710-004600   BD2496
      PIC 1          REV 04   750-001895   HE0885            1x OC-12 SONET, MM
      PIC 2          REV 06   750-003009   HE1422            4x CT3
      PIC 3          REV 03   750-003837   AP7134            1x Multi Link(32)
    FPC 2            REV 01   710-005078   BE0647            M40e-FPC Type 1
      CPU            REV 01   710-004600   AN4299
      PIC 0          REV 04   750-001895   HD2623            1x OC-12 SONET, MM
      PIC 1          REV 04   750-001895   HE0609            1x OC-12 SONET, MM
      PIC 2          REV 04   750-001895   HE0871            1x OC-12 SONET, MM
    FPC 3            REV 01   710-005197   BD9846            M40e-FPC Type 2
      CPU            REV 01   710-004600   BD2364
      PIC 0          REV 01   750-001900   AA9649            1x OC-48 SONET, SMIR
    FPC 5            REV 01   710-005078   BE0639            M40e-FPC Type 1
      CPU            REV 01   710-004600   BD2587
      PIC 2          REV 04   750-001896   AV4480            1x OC-12 SONET, SMIR
      PIC 3          REV 04   750-001895   HE1000            1x OC-12 SONET, MM
    FPC 7            REV 01   710-005196   BD9456            M40e-FPC
      CPU            REV 01   710-004600   AN4323
      PIC 0          REV 01   750-004944   AY4645            8x FE-FX, 100 BASE-FX
      PIC 2          REV 01   750-007927   AP1919            1x Link Service(4)
    

    To verify Routing Engine status, use the show chassis routing-engine command. Sample command output from an M40e router is as follows:

    user@host> show chassis routing-engine
    Routing Engine status:
      Slot 0:
        Current state          Master
        Election priority          Master (default)
        Temperature                           34 degrees C / 93 degrees F
        DRAM                                768 MB
        Memory utilization                   9 percent
        CPU utilization:
          User                        0 percent
          Background                         0 percent
          Kernel                      2 percent
          Interrupt                    0 percent
          Idle                               97 percent
        Model                          RE-2.0
        Serial ID                      9c000007c8644701
        Start time                     2002-06-24 10:33:41 PDT
        Uptime                         31 minutes, 7 seconds
        Load averages:                 1 minute   5 minute  15 minute
                                           0.01       0.02       0.00
    Routing Engine status:
      Slot 1:
        Current state                  Present
    

    To verify FPC status, use the show chassis fpc command. Sample command output from an M40e router is as follows:

    user@host> show chassis fpc
    Temp  CPU Utilization (%)   Memory    Utilization (%)
    Slot State            (C)  Total  Interrupt      DRAM (MB) Heap     Buffer
      0  Online            41      4          0        32         3         40
      1  Empty              0      0          0         0         0          0
      2  Online            43      4          0        32         1         40
      3  Online            38      1          0        32         1         40
      4  Empty              0      0          0         0         0          0
      5  Online            46      4          0        32         1         40
      6  Empty              0      0          0         0         0          0
      7  Online            44      4          0        32         2         39
    

    Table 34 provides an example of jnxFruEntry objects in the jnxFruTable of a T640 router.

    Table 34: jnxFruEntry Objects in the jnxFruTable of a T640 Router

    Index

    L1

    L2

    L3

    Name

    Type

    Slot

    State

    Temp

    Offline

    PowerOff

    PowerOn

    Uptime

    2

    1

    0

    0

    PEM 0

    power EntryModule

    1

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    2

    2

    0

    0

    PEM 1

    power EntryModule

    2

    Online

    27

    None

    0:0:00:00.00

    0:0:00:00.00

    217044

    4

    1

    1

    0

    Top left front fan

    fan

    1

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    4

    1

    2

    0

    Top left middle fan

    fan

    1

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    4

    1

    3

    0

    Top left rear fan

    fan

    1

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    4

    1

    4

    0

    Top right front fan

    fan

    1

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    4

    1

    5

    0

    Top right middle fan

    fan

    1

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    4

    1

    6

    0

    Top right rear fan

    fan

    1

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    4

    2

    1

    0

    Bottom left front fan

    fan

    2

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    4

    2

    2

    0

    Bottom left middle fan

    fan

    2

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    4

    2

    3

    0

    Bottom left rear fan

    fan

    2

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    4

    2

    4

    0

    Bottom right front fan

    fan

    2

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    4

    2

    5

    0

    Bottom right middle fan

    fan

    2

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    4

    2

    6

    0

    Bottom right rear fan

    fan

    2

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    4

    3

    1

    0

    Fourth blower from top

    fan

    3

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    4

    3

    2

    0

    Bottom blower

    fan

    3

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    4

    3

    3

    0

    Middle blower

    fan

    3

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    4

    3

    4

    0

    Top blower

    fan

    3

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    4

    3

    5

    0

    Second blower from top

    fan

    3

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    7

    1

    0

    0

    FPC @ 0/*/*

    flexiblePic Concentrator

    1

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    7

    1

    1

    0

    FPC @ 0/0/* top temper- ature sensor

    flexiblePic Concentrator

    1

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    7

    1

    2

    0

    FPC @ 0/1/* bottom temper- ature sensor

    flexiblePic Concentrator

    1

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    7

    2

    0

    0

    FPC @ 1/*/*

    flexiblePic Concentrator

    2

    Online

    30

    None

    0:0:00:01.94

    0:0:00:00.00

    0

    7

    2

    1

    0

    FPC @ 1/0/* top temper- ature sensor

    flexiblePic Concentrator

    2

    Online

    30

    None

    0:0:00:01.94

    0:0:00:00.00

    0

    7

    2

    2

    0

    FPC @ 1/1/* bottom temper- ature sensor

    flexiblePic Concentrator

    2

    Online

    30

    None

    0:0:00:01.94

    0:0:00:00.00

    0

    7

    3

    0

    0

    FPC @ 2/*/*

    flexiblePic Concentrator

    3

    Online

    30

    None

    0:0:00:01.96

    0:0:00:00.00

    0

    7

    3

    1

    0

    FPC @ 2/0/* top temper- ature sensor

    flexiblePic Concentrator

    3

    Online

    30

    None

    0:0:00:01.96

    0:0:00:00.00

    0

    7

    3

    2

    0

    FPC @ 2/1/* bottom temper- ature sensor

    flexiblePic Concentrator

    3

    Online

    30

    None

    0:0:00:01.96

    0:0:00:00.00

    0

    7

    4

    0

    0

    FPC @ 3/*/*

    flexiblePic Concentrator

    4

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    7

    4

    1

    0

    FPC @ 3/0/* top temper- ature sensor

    flexiblePic Concentrator

    4

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    7

    4

    2

    0

    FPC @ 3/1/* bottom temper- ature sensor

    flexiblePic Concentrator

    4

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    7

    5

    9

    0

    FPC @ 4/*/*

    flexiblePic Concentrator

    5

    Online

    36

    None

    0:0:00:01.98

    0:0:00:00.00

    0

    7

    5

    1

    0

    FPC @ 4/0/* top temper- ature sensor

    flexiblePic Concentrator

    5

    Online

    36

    None

    0:0:00:01.98

    0:0:00:00.00

    0

    7

    5

    2

    0

    FPC @ 4/1/* bottom temper- ature sensor

    flexiblePic Concentrator

    5

    Online

    36

    None

    0:0:00:01.98

    0:0:00:00.00

    0

    7

    6

    0

    0

    FPC @ 5/*/*

    flexiblePic Concentrator

    6

    Offline

    0

    Error

    0:0:12:51.28

    0:0:00:00.00

    0

    7

    6

    1

    0

    FPC @ 5/0/* top temper- ature sensor

    flexiblePic Concentrator

    6

    Offline

    0

    Error

    0:0:12:51.28

    0:0:00:00.00

    0

    7

    6

    2

    0

    FPC @ 5/1/* bottom temper- ature sensor

    flexiblePic Concentrator

    6

    Offline

    0

    Error

    0:0:12:51.28

    0:0:00:00.00

    0

    7

    7

    0

    0

    FPC @ 6/*/*

    flexiblePic Concentrator

    7

    Online

    30

    None

    0:0:00:02.05

    0:0:00:00.00

    0

    7

    7

    1

    0

    FPC @ 6/0/* top temper- ature sensor

    flexiblePic Concentrator

    7

    Online

    30

    None

    0:0:00:02.05

    0:0:00:00.00

    0

    7

    7

    2

    0

    FPC @ 6/1/* bottom temper- ature sensor

    flexiblePic Concentrator

    7

    Online

    30

    None

    0:0:00:02.05

    0:0:00:00.00

    0

    7

    8

    0

    0

    FPC @ 7/*/*

    flexiblePic Concentrator

    8

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    7

    8

    1

    0

    FPC @ 7/0/* top temper- ature sensor

    flexiblePic Concentrator

    8

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    7

    8

    2

    0

    FPC @ 7/1/* bottom temper- ature sensor

    flexiblePic Concentrator

    8

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    1

    1

    0

    PIC: @ 0/0/*

    portInterface- Card

    1

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    1

    2

    0

    PIC: @ 0/1/*

    portInterface- Card

    1

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    1

    3

    0

    PIC: @ 0/2/*

    portInterface- Card

    1

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    1

    4

    0

    PIC: @ 0/3/*

    portInterface- Card

    1

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    2

    1

    0

    PIC: 1x OC-48 SONET, SMIR @ 1/0/*

    portInterface- Card

    2

    Online

     

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    2

    2

    0

    PIC: 1x OC-48 SONET, SMSR @ 1/1/*

    portInterface- Card

    2

    Online

    36

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    2

    3

    0

    PIC: 1x OC-48 SONET, SMIR @ 1/2/*

    portInterface- Card

    2

    Online

    36

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    2

    4

    0

    PIC: 1x OC-48 SONET, SMIR @ 1/3/*

    portInterface- Card

    2

    Online

    36

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    3

    1

    0

    PIC: @ 2/0/*

    portInterface- Card

    3

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    3

    2

    0

    PIC: @ 2/1/*

    portInterface- Card

    3

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    3

    3

    0

    PIC: @ 2/2/*

    portInterface- Card

    3

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    3

    4

    0

    PIC: @ 2/3/*

    portInterface- Card

    3

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    4

    1

    0

    PIC: @ 3/0/*

    portInterface- Card

    4

    Online

     

    None

    0:0:00:01.00

    0:0:00:00.00

    0

    8

    4

    2

    0

    PIC: @ 3/1/*

    portInterface- Card

    4

    Online

    30

    None

    0:0:00:01.94

    0:0:00:00.00

    0

    8

    4

    3

    0

    PIC: @ 3/2/*

    portInterface- Card

    4

    Online

    30

    None

    0:0:00:01.94

    0:0:00:00.00

    0

    8

    4

    4

    0

    PIC: @ 3/3/*

    portInterface- Card

    4

    Online

    30

    None

    0:0:00:01.94

    0:0:00:00.00

    0

    8

    5

    1

    0

    PIC: 1x Tunnel @ 4/0/*

    portInterface- Card

    5

    Online

    30

    None

    0:0:00:01.94

    0:0:00:00.00

    0

    8

    5

    2

    0

    PIC: 1x OC-192 SM SR2 @ 4/1/*

    portInterface- Card

    5

    Online

    30

    None

    0:0:00:01.96

    0:0:00:00.00

    0

    8

    5

    3

    0

    PIC: 4x OC-48 SONET, SMSR @ 4/2/*

    portInterface- Card

    5

    Online

    30

    None

    0:0:00:01.96

    0:0:00:00.00

    0

    8

    5

    4

    0

    PIC: 1x OC-192 SM SR1 @ 4/3/*

    portInterface- Card

    5

    Online

    30

    None

    0:0:00:01.96

    0:0:00:00.00

    0

    8

    6

    1

    0

    PIC: @ 5/0/*

    portInterface- Card

    6

    Empty

    0

    None

    0:0:00:01.00

    0:0:00:00.00

    0

    8

    6

    2

    0

    PIC: @ 5/1/*

    portInterface- Card

    6

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    6

    3

    0

    PIC: @ 5/2/*

    portInterface- Card

    6

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    6

    4

    0

    PIC: @ 5/3/*

    portInterface- Card

    6

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    7

    1

    0

    PIC: @ 6/0/*

    portInterface- Card

    7

    Online

    30

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    7

    2

    0

    PIC: @ 6/1/*

    portInterface- Card

    7

    Online

    30

    None

    0:0:00:01.98

    0:0:00:00.00

    0

    8

    7

    3

    0

    PIC: @ 6/2/*

    portInterface- Card

    7

    Online

    30

    None

    0:0:00:01.98

    0:0:00:00.00

    0

    8

    7

    4

    0

    PIC: @ 6/3/*

    portInterface- Card

    7

    Online

    30

    None

    0:0:00:01.98

    0:0:00:00.00

    0

    8

    8

    1

    0

    PIC: @ 7/0/*

    portInterface- Card

    8

    Offline

    0

    Error

    0:0:12:51.28

    0:0:00:00.00

    0

    8

    8

    2

    0

    PIC: @ 7/1/*

    portInterface- Card

    8

    Offline

    0

    Error

    0:0:12:51.28

    0:0:00:00.00

    0

    8

    8

    3

    0

    PIC: @ 7/2/*

    portInterface- Card

    8

    Offline

    0

    Error

    0:0:12:51.28

    0:0:00:00.00

    0

    8

    8

    4

    0

    PIC: @ 7/3/*

    portInterface- Card

    8

    Offline

    0

    Error

    0:0:12:51.28

    0:0:00:00.00

    0

    9

    1

    0

    0

    Routing Engine 0

    routing- Engine

    1

    Online

    34

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    9

    2

    0

    0

    Routing Engine 1

    routing- Engine

    2

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    10

    1

    1

    0

    FPM GBUS

    frontPanel- Module

    1

    Online

    27

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    10

    1

    2

    0

    FPM Display

    frontPanel- Module

    1

    Online

    27

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    11

    1

    0

    0

    SCG 0

    clockGener ator

    1

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    11

    2

    0

    0

    SCG 1

    clockGener ator

    2

    Online

    27

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    12

    1

    0

    0

    CB 0

    control- Board

    1

    Online

    27

    None

    0:0:00:01.94

    0:0:00:00.00

    0

    12

    2

    0

    0

    CB 1

    control- Board

    2

    Unknown

    0

    None

    0:0:00:01.96

    0:0:00:00.00

    0

    13

    1

    0

    0

    CIP

    craftInter- facePanel

    1

    Present

    36

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    14

    1

    0

    0

    SPMB 0

    processor Mezzanine BoardForSIB

    1

    Online

    34

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    14

    2

    0

    0

    SPMB 1

    processor Mezzanine BoardForSIB

    2

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    15

    1

    0

    0

    SIB 0

    switchInter- faceBoard

    1

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    15

    2

    0

    0

    SIB 1

    switchInter- faceBoard

    2

    Online

    36

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    15

    3

    0

    0

    SIB 2

    switchInter- faceBoard

    3

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    15

    4

    0

    0

    SIB 3

    switchInter- faceBoard

    4

    Online

    30

    None

    0:0:00:01.94

    0:0:00:00.00

    0

    15

    5

    0

    0

    SIB 4

    switchInter- faceBoard

    5

    Online

    30

    None

    0:0:00:01.96

    0:0:00:00.00

    0

    To verify the L1, L2, and L3 indexes, use the show chassis hardware command. Sample command output from a T640 router is as follows:

    user@host> show chassis hardware
    Hardware inventory:
    Item             Version  Part number  Serial number     Description
    Chassis                                1234              T640
    Midplane         REV 04   710-002726   AX5603
    FPM GBUS         REV 02   710-002901   HE3062
    FPM Display      REV 01   710-002897   HD3033
    CIP              REV 05   710-002895   HA5022
    PEM 1            RevX02   740-002595   MD21812           Power Entry Module
    SCG 1            REV 01   710-003423   HD3025
    Routing Engine 0 REV 01   740-005022   210865700336      RE-3.0
    CB 0             REV 02   710-002728   HE3025
    CB 1
    FPC 1            REV 01   710-002385   HE3173            FPC Type 2
      CPU            REV 06   710-001726   HC0042
      PIC 0          REV 03   750-001900   AD5737            1x OC-48 SONET, SMIR
      PIC 1          REV 07   750-001900   AR3613            1x OC-48 SONET, SMSR
      PIC 2          REV 01   750-001900   AA9604            1x OC-48 SONET, SMIR
      PIC 3          REV 01   750-001900   AA9602            1x OC-48 SONET, SMIR
      MMB 1          REV 03   710-001723   HC0111            MMB-144mbit
      ICBM           REV 04   710-003384   HA4497
      PPB 0          REV 02   710-003758   HA4543            PPB Type 2
      PPB 1          REV 02   710-003758   HA4540            PPB Type 2
    FPC 2            REV 01   710-002385   HE3180            FPC Type 2
      CPU            REV 06   710-001726   HE7904
      MMB 1          REV 03   710-001723   HC0120            MMB-144mbit
      ICBM           REV 01   710-003384   HE3046
      PPB 0          REV 02   710-003758   HA4564            PPB Type 2
      PPB 1          REV 02   710-003758   HA4554            PPB Type 2
    FPC 4            REV 04   710-001721   HE3145            FPC Type 3
      CPU            REV 06   710-001726   HC0034
      PIC 0                                                  1x Tunnel
      PIC 1          REV 01   750-003824   HE7803            1x OC-192 SM SR2
      PIC 2          REV 01   750-003336   HE3420            4x OC-48 SONET, SMSR
      PIC 3          REV 01   750-003824   HE7802            1x OC-192 SM SR1
      MMB 0          REV 03   710-001723   HE7230            MMB-144mbit
      MMB 1          REV 03   710-001723   HE7267            MMB-144mbit
      ICBM           REV 04   710-003384   HA4485
      PPB 0          REV 02   710-002845   HA4550            PPB Type 3
      PPB 1          REV 02   710-002845   HA4525            PPB Type 3
    FPC 5            REV 04   710-001721   HE3175            FPC Type 3
      CPU
    FPC 6            REV 01   710-002385   HD5027            FPC Type 2
      CPU            REV 06   710-001726   HC0033
      MMB 1          REV 03   710-001723   HC0080            MMB-144mbit
      ICBM           REV 04   710-003384   HA4486
      PPB 0          REV 02   710-003758   HA4541            PPB Type 2
      PPB 1          REV 02   710-003758   HA4539            PPB Type 2
    SPMB 0           REV 01   710-003229   HA5999
    SIB 0            REV 01   710-003980   HD5054            SIB-I8
    SIB 2            REV 01   710-003980   HC0035            SIB-I8
    SIB 3            REV 01   710-003980   HA5065            SIB-I8
    SIB 4            REV 01   710-003980   HE3016            SIB-I8
    

    To verify FPC status, use the show chassis fpc command. Sample command output from a T640 router is as follows:

    user@host> show chassis fpc
    Temp  CPU Utilization (%)   Memory    Utilization (%)
    Slot State            (C)  Total  Interrupt      DRAM (MB) Heap     Buffer
      0  Empty              0      0          0         0         0          0
      1  Online            30      2          0       512         3         41
      2  Online            30      2          0       256         7         41
      3  Empty              0      0          0         0         0          0
      4  Online            30      4          0       512         6         41
      5  Offline         --- Unresponsive ---
      6  Online            30      2          0       256         7         41
      7  Empty              0      0          0         0         0          0
    

    To verify Routing Engine status, use the show chassis routing-engine command. Sample command output from a T640 router is as follows:

    user@host> show chassis routing-engine
    Routing Engine status:
      Slot 0:
        Current state                  Master
        Election priority              Master (default)
        Temperature                 35 degrees C / 95 degrees F
        DRAM                      2048 MB
        Memory utilization           4 percent
        CPU utilization:
          User                       0 percent
          Background                 0 percent
          Kernel                     2 percent
          Interrupt                  0 percent
          Idle                      97 percent
        Model                          RE-3.0
        Start time                     2002-06-24 10:33:34 PDT
        Uptime                         33 minutes, 38 seconds
        Load averages:                 1 minute   5 minute  15 minute
                                           0.08       0.03       0.01
    

    To verify SPMB status, use the show chassis spmb command. Sample command output from a T640 router is as follows:

    user@host> show chassis spmb
    Slot 0 information:
      State                          Online
      Total CPU Utilization             2%
      Interrupt CPU Utilization         0%
      Memory Heap Utilization           0%
      Buffer Utilization               40%
      Start time:                    2002-06-24 10:34:22 PDT
      Uptime:                         33 minutes, 3 seconds
    

    Table 35 provides an example of jnxFruEntry objects in the jnxFruTable of a T4000 router.

    Table 35: jnxFruEntry Objects in the jnxFruTable of a T4000 Router

    Index

    L1

    L2

    L3

    Name

    Type

    Slot

    State

    Temp

    Offline

    PowerOff

    PowerOn

    Uptime

    2

    1

    0

    0

    PEM 0

    power EntryModule

    1

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    2

    2

    0

    0

    PEM 1

    power EntryModule

    0

    Online

    27

    None

    0:0:00:00.00

    0:0:00:00.00

    217044

    4

    1

    1

    0

    Front Top Fan Tray

    fan

    0

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    4

    1

    1

    0

    Top Left Front fan

    fan

    0

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    4

    1

    2

    0

    Top left Middle fan

    fan

    0

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    4

    1

    3

    0

    Top left rear fan

    fan

    0

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    4

    1

    3

    0

    Top right rear fan

    fan

    1

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    4

    1

    4

    0

    Top right front fan

    fan

    1

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    4

    1

    5

    0

    Top right middle fan

    fan

    1

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    4

    1

    6

    0

    Top right rear fan

    fan

    1

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    4

    2

    0

    0

    Front Bottom Fan Tray

    fan

    2

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    4

    2

    1

    0

    Bottom left front fan

    fan

    2

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    4

    2

    2

    0

    Bottom left middle fan

    fan

    2

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    4

    2

    3

    0

    Bottom left rear fan

    fan

    2

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    4

    2

    4

    0

    Bottom right front fan

    fan

    2

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    4

    2

    5

    0

    Bottom right middle fan

    fan

    2

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    4

    2

    6

    0

    Bottom right rear fan

    fan

    2

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    4

    3

    0

    0

    Rear fan tray

    fan

    2

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    4

    3

    1

    0

    Rear Tray Top fan

    fan

    3

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    4

    3

    2

    0

    Rear Tray Second fan

    fan

    3

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    4

    3

    3

    0

    Rear Tray Third fan

    fan

    3

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    4

    3

    4

    0

    Rear Tray Fourth fan

    fan

    3

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    4

    3

    5

    0

    Rear Tray Fifth fan

    fan

    3

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    4

    3

    6

    0

    Rear Tray Sixth fan

    fan

    3

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    4

    3

    7

    0

    Rear Tray seventh fan

    fan

    3

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    4

    3

    8

    0

    Rear Tray Bottom fan

    fan

    3

    Present

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    7

    1

    3

    0

    ST-MMB2 @ 0/*/* MMB0

    flexiblePic Concentrator

    0

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    7

    1

    4

    0

    FPC @ 0/*/* MMB1

    flexiblePic Concentrator

    0

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    7

    2

    0

    0

    FPC Type 4-ES @ 1/*/*

    flexiblePic Concentrator

    1

    Online

    30

    None

    0:0:00:01.94

    0:0:00:00.00

    0

    7

    2

    1

    0

    FPC Type 4-ES @ 1/*/* top temperaturesensor

    flexiblePic Concentrator

    1

    Online

    30

    None

    0:0:00:01.94

    0:0:00:00.00

    0

    7

    2

    2

    0

    FPC Type 4-ES @ 1/*/* bottom temperaturesensor

    flexiblePic Concentrator

    1

    Online

    30

    None

    0:0:00:01.94

    0:0:00:00.00

    0

    7

    2

    3

    0

    ST-MMB2 @ 1/*/* MMB0

    flexiblePic Concentrator

    1

    Online

    30

    None

    0:0:00:01.94

    0:0:00:00.00

    0

    7

    2

    4

    0

    ST-MMB2 @ 1/*/* MMB1

    flexiblePic Concentrator

    1

    Online

    30

    None

    0:0:00:01.94

    0:0:00:00.00

    0

    7

    3

    0

    0

    FPC Type 5-3D @ 2/*/*

    flexiblePic Concentrator

    2

    Online

    30

    None

    0:0:00:01.96

    0:0:00:00.00

    0

    7

    3

    1

    0

    FPC Type 5-3D @ 2/*/* intake

    flexiblePic Concentrator

    2

    Online

    30

    None

    0:0:00:01.96

    0:0:00:00.00

    0

    7

    3

    2

    0

    FPC Type 5-3D @ 2/*/* exhaust

    flexiblePic Concentrator

    2

    Online

    30

    None

    0:0:00:01.96

    0:0:00:00.00

    0

    7

    3

    3

    0

    FPC @ 2/*/* MMB0

    flexiblePic Concentrator

    2

    Online

    30

    None

    0:0:00:01.96

    0:0:00:00.00

    0

    7

    3

    4

    0

    FPC @ 2/*/* MMB1

    flexiblePic Concentrator

    2

    Online

    30

    None

    0:0:00:01.96

    0:0:00:00.00

    0

    7

    4

    0

    0

    FPC @ 3/*/*

    flexiblePic Concentrator

    3

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    7

    4

    1

    0

    FPC @ 3/*/* top temperaturesensor

    flexiblePic Concentrator

    3

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    7

    4

    2

    0

    FPC @ 3/*/* bottom temperaturesensor

    flexiblePic Concentrator

    3

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    7

    4

    3

    0

    FPC @ 3/*/* MMB0

    flexiblePic Concentrator

    3

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    7

    4

    4

    0

    FPC @ 3/*/* MMB1

    flexiblePic Concentrator

    3

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    7

    5

    0

    0

    FPC Type 5-3D @ 4/*/*

    flexiblePic Concentrator

    4

    Online

    36

    None

    0:0:00:01.98

    0:0:00:00.00

    0

    7

    5

    1

    0

    FPC Type 5-3D @ 4/*/* intake

    flexiblePic Concentrator

    4

    Online

    36

    None

    0:0:00:01.98

    0:0:00:00.00

    0

    7

    5

    2

    0

    FPC Type 5-3D @ 4/*/* exhaust

    flexiblePic Concentrator

    4

    Online

    36

    None

    0:0:00:01.98

    0:0:00:00.00

    0

    7

    5

    3

    0

    FPC @ 4/*/* MMB0

    flexiblePic Concentrator

    4

    Online

    36

    None

    0:0:00:01.98

    0:0:00:00.00

    0

    7

    5

    4

    0

    FPC @ 4/*/* MMB1

    flexiblePic Concentrator

    4

    Online

    36

    None

    0:0:00:01.98

    0:0:00:00.00

    0

    7

    6

    0

    0

    FPC @ 5/*/*

    flexiblePic Concentrator

    5

    Offline

    0

    Error

    0:0:12:51.28

    0:0:00:00.00

    0

    7

    6

    1

    0

    FPC @ 5/*/* top temperature sensor

    flexiblePic Concentrator

    5

    Offline

    0

    Error

    0:0:12:51.28

    0:0:00:00.00

    0

    7

    6

    2

    0

    FPC @ 5/*/* bottom temperature sensor

    flexiblePic Concentrator

    5

    Offline

    0

    Error

    0:0:12:51.28

    0:0:00:00.00

    0

    7

    6

    3

    0

    FPC @ 5/*/* MMB0

    flexiblePic Concentrator

    5

    Offline

    0

    Error

    0:0:12:51.28

    0:0:00:00.00

    0

    7

    6

    2

    0

    FPC @ 5/*/* MMB1

    flexiblePic Concentrator

    5

    Offline

    0

    Error

    0:0:12:51.28

    0:0:00:00.00

    0

    7

    7

    0

    0

    FPC @ 6/*/*

    flexiblePic Concentrator

    6

    Online

    30

    None

    0:0:00:02.05

    0:0:00:00.00

    0

    7

    7

    1

    0

    FPC @ 6/0/* top temperature sensor

    flexiblePic Concentrator

    6

    Online

    30

    None

    0:0:00:02.05

    0:0:00:00.00

    0

    7

    7

    2

    0

    FPC @ 6/1/* bottom temperature sensor

    flexiblePic Concentrator

    6

    Online

    30

    None

    0:0:00:02.05

    0:0:00:00.00

    0

    7

    7

    3

    0

    FPC @ 6/*/* MMB0

    flexiblePic Concentrator

    6

    Online

    30

    None

    0:0:00:02.05

    0:0:00:00.00

    0

    7

    7

    4

    0

    FPC @ 6/*/* MMB1

    flexiblePic Concentrator

    6

    Online

    30

    None

    0:0:00:02.05

    0:0:00:00.00

    0

    7

    8

    0

    0

    FPC @ 7/*/*

    flexiblePic Concentrator

    7

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    7

    8

    1

    0

    FPC @ 7/*/* top temperature sensor

    flexiblePic Concentrator

    7

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    7

    8

    2

    0

    FPC @ 7/*/* bottom temperature sensor

    flexiblePic Concentrator

    7

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    7

    8

    3

    0

    FPC @ 7/*/* MMB0

    flexiblePic Concentrator

    7

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    7

    8

    4

    0

    FPC @ 7/*/* MMB1

    flexiblePic Concentrator

    7

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    1

    4

    0

    PIC: @ 0/3/*

    portInterface- Card

    0

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    2

    1

    0

    PIC: @ 1/0/*

    portInterface- Card

    1

    Online

     

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    2

    2

    0

    PIC: @ 1/1/*

    portInterface- Card

    1

    Online

    36

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    2

    3

    0

    PIC: @ 1/2/*

    portInterface- Card

    1

    Online

    36

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    2

    4

    0

    PIC: @ 1/3/*

    portInterface- Card

    1

    Online

    36

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    3

    1

    0

    PIC: 12x10GE (LAN/WAN) SFPP @ 2/0/*

    portInterface- Card

    2

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    3

    2

    0

    PIC: 12x10GE (LAN/WAN) SFPP @ 2/1/*

    portInterface- Card

    2

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    3

    3

    0

    PIC: @ 2/2/*

    portInterface- Card

    2

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    3

    4

    0

    PIC: @ 2/3/*

    portInterface- Card

    2

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    4

    1

    0

    PIC: @ 3/0/*

    portInterface- Card

    3

    Online

     

    None

    0:0:00:01.00

    0:0:00:00.00

    0

    8

    4

    2

    0

    PIC: @ 3/1/*

    portInterface- Card

    3

    Online

    30

    None

    0:0:00:01.94

    0:0:00:00.00

    0

    8

    4

    3

    0

    PIC: @ 3/2/*

    portInterface- Card

    3

    Online

    30

    None

    0:0:00:01.94

    0:0:00:00.00

    0

    8

    4

    4

    0

    PIC: @ 3/3/*PIC: @ 3/3/*

    portInterface- Card

    3

    Online

    30

    None

    0:0:00:01.94

    0:0:00:00.00

    0

    8

    5

    1

    0

    PIC: 24x10GE (LAN/WAN) SFPP @ 4/0/*

    portInterface- Card

    4

    Online

    30

    None

    0:0:00:01.94

    0:0:00:00.00

    0

    8

    5

    2

    0

    PIC: 12x10GE (LAN/WAN) SFPP @ 4/1/*

    portInterface- Card

    4

    Online

    30

    None

    0:0:00:01.96

    0:0:00:00.00

    0

    8

    5

    4

    0

    PIC: @ 4/3/*

    portInterface- Card

    4

    Online

    30

    None

    0:0:00:01.96

    0:0:00:00.00

    0

    8

    6

    1

    0

    PIC: @ 5/0/*

    portInterface- Card

    5

    Empty

    0

    None

    0:0:00:01.00

    0:0:00:00.00

    0

    8

    6

    2

    0

    PIC: @ 5/1/*

    portInterface- Card

    5

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    6

    3

    0

    PIC: @ 5/2/*

    portInterface- Card

    5

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    6

    4

    0

    PIC: @ 5/3/*

    portInterface- Card

    5

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    7

    1

    0

    PIC: @ 6/0/*

    portInterface- Card

    6

    Online

    30

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    8

    7

    2

    0

    PIC: @ 6/1/*

    portInterface- Card

    6

    Online

    30

    None

    0:0:00:01.98

    0:0:00:00.00

    0

    8

    7

    3

    0

    PIC: @ 6/2/*

    portInterface- Card

    6

    Online

    30

    None

    0:0:00:01.98

    0:0:00:00.00

    0

    8

    7

    4

    0

    PIC: @ 6/3/*

    portInterface- Card

    6

    Online

    30

    None

    0:0:00:01.98

    0:0:00:00.00

    0

    8

    8

    1

    0

    PIC: @ 7/0/*

    portInterface- Card

    7

    Offline

    0

    Error

    0:0:12:51.28

    0:0:00:00.00

    0

    8

    8

    2

    0

    PIC: @ 7/1/*

    portInterface- Card

    7

    Offline

    0

    Error

    0:0:12:51.28

    0:0:00:00.00

    0

    8

    8

    3

    0

    PIC: @ 7/2/*

    portInterface- Card

    7

    Offline

    0

    Error

    0:0:12:51.28

    0:0:00:00.00

    0

    8

    8

    4

    0

    PIC: @ 7/3/*

    portInterface- Card

    7

    Offline

    0

    Error

    0:0:12:51.28

    0:0:00:00.00

    0

    9

    1

    0

    0

    Routing Engine 0

    routing- Engine

    1

    Online

    34

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    9

    2

    0

    0

    Routing Engine 1

    routing- Engine

    2

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    10

    1

    1

    0

    FPM GBUS

    frontPanel- Module

    1

    Online

    27

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    10

    1

    2

    0

    FPM Display

    frontPanel- Module

    1

    Online

    27

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    11

    1

    0

    0

    SCG 0

    clockGener ator

    1

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    11

    2

    0

    0

    SCG 1

    clockGener ator

    2

    Online

    27

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    12

    1

    0

    0

    CB 0

    control- Board

    1

    Online

    27

    None

    0:0:00:01.94

    0:0:00:00.00

    0

    12

    2

    0

    0

    CB 1

    control- Board

    2

    Unknown

    0

    None

    0:0:00:01.96

    0:0:00:00.00

    0

    13

    1

    0

    0

    CIP

    craftInter- facePanel

    1

    Present

    36

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    14

    1

    0

    0

    SPMB 0

    processor Mezzanine BoardForSIB

    1

    Online

    34

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    14

    2

    0

    0

    SPMB 1

    processor Mezzanine BoardForSIB

    2

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    15

    1

    0

    0

    SIB 0

    switchInter- faceBoard

    1

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    15

    2

    0

    0

    SIB 1

    switchInter- faceBoard

    2

    Online

    36

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    15

    3

    0

    0

    SIB 2

    switchInter- faceBoard

    3

    Empty

    0

    None

    0:0:00:00.00

    0:0:00:00.00

    0

    15

    4

    0

    0

    SIB 3

    switchInter- faceBoard

    4

    Online

    30

    None

    0:0:00:01.94

    0:0:00:00.00

    0

    15

    5

    0

    0

    SIB 4

    switchInter- faceBoard

    5

    Online

    30

    None

    0:0:00:01.96

    0:0:00:00.00

    0

    To verify the L1, L2, and L3 indexes, use the show chassis hardware command. Sample command output from a T4000 router is as follows:

    user@host> show chassis hardware
    Hardware inventory:
    Item             Version  Part number  Serial number     Description
    Chassis                                JN1172F25AHA      T4000
    Midplane         REV 01   710-027486   RC8355            T-series Backplane
    FPM GBUS         REV 13   710-002901   BBAE0927          T640 FPM Board
    FPM Display      REV 01   710-021387   EF6764            T1600 FPM Display
    CIP              REV 06   710-002895   BBAD9210          T-series CIP
    PEM 0            REV 01   740-036442   VA00016           Power Entry Module 6x60
    SCG 0            REV 18   710-003423   BBAD7248          T640 Sonet Clock Gen.
    SCG 1            REV 18   710-003423   BBAE3874          T640 Sonet Clock Gen.
    Routing Engine 0 REV 05   740-026941   P737F-002248      RE-DUO-1800
    Routing Engine 1 REV 06   740-026941   P737F-002653      RE-DUO-1800
    CB 0             REV 09   710-022597   ED0295            LCC Control Board
    CB 1             REV 09   710-022597   EA6050            LCC Control Board
    FPC 0            REV 26   750-032819   EK1173            FPC Type 5-3D
      CPU            REV 12   711-030686   EJ8584            SNG PMB
      PIC 0          REV 07   750-034624   EF6837            12x10GE (LAN/WAN) SFPP
        Xcvr 0       REV 01   740-031980   123363A01145      SFP+-10G-SR
        Xcvr 1       REV 01   740-031980   123363A01147      SFP+-10G-SR
        Xcvr 2       REV 01   740-031980   AJJ01P3           SFP+-10G-SR
        Xcvr 3       REV 01   740-031980   B10M03256         SFP+-10G-SR
        Xcvr 4       REV 01   740-031980   AJJ01M2           SFP+-10G-SR
        Xcvr 5       REV 01   740-031980   123363A01137      SFP+-10G-SR
        Xcvr 6       REV 01   740-031980   AJJ01PN           SFP+-10G-SR
        Xcvr 7       REV 01   740-031980   AJJ01NW           SFP+-10G-SR
        Xcvr 8       REV 01   740-031980   123363A01139      SFP+-10G-SR
        Xcvr 9       REV 01   740-031980   AJJ01KE           SFP+-10G-SR
        Xcvr 10      REV 01   740-031980   123363A01336      SFP+-10G-SR
        Xcvr 11      REV 01   740-031980   B10M01325         SFP+-10G-SR
      PIC 1          REV 07   750-034624   EF6800            12x10GE (LAN/WAN) SFPP
        Xcvr 0       REV 01   740-031980   AJJ01SA           SFP+-10G-SR
        Xcvr 1       REV 01   740-031980   AJJ01QZ           SFP+-10G-SR
        Xcvr 2       REV 01   740-031980   AJH0217           SFP+-10G-SR
        Xcvr 3       REV 01   740-031980   AJJ01TE           SFP+-10G-SR
        Xcvr 4       REV 01   740-031980   AJJ01KV           SFP+-10G-SR
        Xcvr 5       REV 01   740-031980   AJJ01MU           SFP+-10G-SR
        Xcvr 6       REV 01   740-031980   AJJ01R0           SFP+-10G-SR
        Xcvr 7       REV 01   740-031980   AJJ01TC           SFP+-10G-SR
        Xcvr 8       REV 01   740-031980   AJJ0364           SFP+-10G-SR
        Xcvr 9       REV 01   740-031980   AJD0GV3           SFP+-10G-SR
        Xcvr 10      REV 01   740-031980   B10M03343         SFP+-10G-SR
        Xcvr 11      REV 01   740-031980   AJJ01QJ           SFP+-10G-SR
      LMB 0          REV 05   711-034381   EJ8490            Type-0 LMB
      LMB 1          REV 04   711-035774   EJ8517            Type-1 LMB
      LMB 2          REV 05   711-034381   EJ8489            Type-0 LMB
    FPC 3            REV 07   750-032819   EG3637            FPC Type 5-3D
      CPU            REV 09   711-030686   EG0150            SNG PMB
      PIC 0          REV 08   750-035293   EF3657            1x100GE
        Xcvr 0       REV 01   740-032210   C22CQNJ           CFP-100G-LR4
      PIC 1          REV 10   750-034624   BBAN4098          12x10GE (LAN/WAN) SFPP
        Xcvr 0       REV 01   740-031980   B11J04902         SFP+-10G-SR
        Xcvr 1       REV 01   740-031980   B11J04891         SFP+-10G-SR
        Xcvr 2       REV 01   740-031980   AJJ01MX           SFP+-10G-SR
        Xcvr 3       REV 01   740-031980   B11J04183         SFP+-10G-SR
        Xcvr 4       REV 01   740-031980   B11J04894         SFP+-10G-SR
        Xcvr 5       REV 01   740-031980   B11J04184         SFP+-10G-SR
        Xcvr 6       REV 01   740-031980   B11J04897         SFP+-10G-SR
        Xcvr 7       REV 01   740-031980   B11J04899         SFP+-10G-SR
        Xcvr 8       REV 01   740-031980   AJJ01TV           SFP+-10G-SR
        Xcvr 9       REV 01   740-031980   B11J04057         SFP+-10G-SR
        Xcvr 10      REV 01   740-031980   AJJ01M4           SFP+-10G-SR
        Xcvr 11      REV 01   740-031980   B11J04905         SFP+-10G-SR
      LMB 0          REV 04   711-034381   EG1524            Type-0 LMB
      LMB 1          REV 03   711-035774   EG0345            Type-1 LMB
      LMB 2          REV 04   711-034381   EG1522            Type-0 LMB
    FPC 5            REV 03   710-033871   BBAJ0768          FPC Type 4-ES
      CPU            REV 11   710-016744   BBAH9342          ST-PMB2
      PIC 0          REV 09   750-029262   EE6789            100GE
      PIC 1          REV 03   750-034781   EE6655            100GE CFP
        Xcvr 0       REV 01   740-032210   J11A22334         CFP-100G-LR4
      BRIDGE 0       REV 03   711-029995   EE6572            100GE Bridge Board
      MMB 0          REV 07   710-025563   BBAJ4657          ST-MMB2
      MMB 1          REV 07   710-025563   BBAJ3073          ST-MMB2
    FPC 6            REV 05   750-010153   EF4936            FPC Type 5-3D
      CPU            REV 06   711-030686   EF4189            SNG PMB
      PIC 0          REV 10   750-034624   BBAN4109          12x10GE (LAN/WAN) SFPP
        Xcvr 0       REV 01   740-031980   B11J04895         SFP+-10G-SR
        Xcvr 1       REV 01   740-031980   B11J04898         SFP+-10G-SR
        Xcvr 2       REV 01   740-031980   B11J04021         SFP+-10G-SR
        Xcvr 3       REV 01   740-031980   B11J04903         SFP+-10G-SR
        Xcvr 4       REV 01   740-031980   B11J04311         SFP+-10G-SR
        Xcvr 5       REV 01   740-031980   B11J04059         SFP+-10G-SR
        Xcvr 6       REV 01   740-031980   B11J04016         SFP+-10G-SR
        Xcvr 7       REV 01   740-031980   B11J04017         SFP+-10G-SR
        Xcvr 8       REV 01   740-031980   B11J04887         SFP+-10G-SR
        Xcvr 9       REV 01   740-031980   B11J04297         SFP+-10G-SR
        Xcvr 10      REV 01   740-031980   B11J04893         SFP+-10G-SR
        Xcvr 11      REV 01   740-031980   B11J04022         SFP+-10G-SR
      PIC 1          REV 02   750-034624   EE3711            12x10GE (LAN/WAN) SFPP
        Xcvr 0       REV 01   740-031980   AJH033X           SFP+-10G-SR
        Xcvr 1       REV 01   740-031980   AJJ01N0           SFP+-10G-SR
        Xcvr 2       REV 01   740-031980   AJJ01SV           SFP+-10G-SR
        Xcvr 3       REV 01   740-031980   AJJ032L           SFP+-10G-SR
        Xcvr 4       REV 01   740-031980   B10M01593         SFP+-10G-SR
        Xcvr 5       REV 01   740-031980   AJD0FF1           SFP+-10G-SR
        Xcvr 6       REV 01   740-031980   AJJ01NU           SFP+-10G-SR
        Xcvr 7       REV 01   740-031980   123363A01305      SFP+-10G-SR
        Xcvr 8       REV 01   740-031980   B10M00361         SFP+-10G-SR
        Xcvr 9       REV 01   740-031980   AJJ01M7           SFP+-10G-SR
        Xcvr 10      REV 01   740-031980   AJJ032X           SFP+-10G-SR
        Xcvr 11      REV 01   740-031980   AJJ01PG           SFP+-10G-SR
      LMB 0          REV 04   711-034381   EF3838            Type-0 LMB
      LMB 1          REV 03   711-035774   EF3821            Type-1 LMB
      LMB 2          REV 04   711-034381   EF3834            Type-0 LMB
    SPMB 0           REV 05   710-023321   ED1990            LCC Switch CPU
    SPMB 1           REV 05   710-023321   EA2768            LCC Switch CPU
    SIB 0            REV 02   711-036340   EF8802            SIB-HC-3D
    SIB 1            REV 07   711-036340   EG2286            SIB-HC-3D
    SIB 2            REV 07   711-036340   EG2252            SIB-HC-3D
    SIB 3            REV 02   711-036340   EF1358            SIB-HC-3D
    SIB 4            REV 02   711-036340   EF8806            SIB-HC-3D
    Fan Tray 0                                               Front Top Fan Tray
    Fan Tray 1                                               Front Bottom Fan Tray -- Rev 2
    Fan Tray 2                                               Rear Fan Tray -- Rev 3

    To verify FPC status, use the show chassis fpc command. Sample command output from a T4000 router is as follows:

    user@host> show chassis fpc
    regress@stymphalian# run show chassis fpc 
                         Temp  CPU Utilization (%)   Memory    Utilization (%)
    Slot State            (C)  Total  Interrupt      DRAM (MB) Heap     Buffer
      0  Online            48     15          0       2816       21         27
      1  Empty           
      2  Empty           
      3  Online            51     15          0       2816       21         27
      4  Empty           
      5  Online            39      8          0       2048        6         23
      6  Online            49     15          0       2816       21         27
      7  Empty           

    To verify Routing Engine status, use the show chassis routing-engine command. Sample command output from a T4000 router is as follows:

    user@host> show chassis routing-engine
    Routing Engine status:
      Slot 0:
        Current state                  Master
        Election priority              Master (default)
        Temperature                 33 degrees C / 91 degrees F
        CPU temperature             50 degrees C / 122 degrees F
        DRAM                      8960 MB
        Memory utilization          18 percent
        CPU utilization:
          User                       0 percent
          Background                 0 percent
          Kernel                     4 percent
          Interrupt                  1 percent
          Idle                      95 percent
        Model                          RE-DUO-1800
        Serial ID                      P737F-002248
        Start time                     2012-02-09 22:49:53 PST
        Uptime                         2 hours, 21 minutes, 35 seconds
        Last reboot reason             Router rebooted after a normal shutdown.
        Load averages:                 1 minute   5 minute  15 minute
                                           0.00       0.04       0.00
    Routing Engine status:
      Slot 1:
        Current state                  Backup
        Election priority              Backup (default)
        Temperature                 32 degrees C / 89 degrees F
        CPU temperature             46 degrees C / 114 degrees F
        DRAM                      8960 MB
        Memory utilization          24 percent
        CPU utilization:
          User                       0 percent
          Background                 0 percent
          Kernel                     0 percent
          Interrupt                  0 percent
          Idle                      99 percent
        Model                          RE-DUO-1800
        Serial ID                      P737F-002653
        Start time                     2012-02-08 20:12:51 PST
        Uptime                         1 day, 4 hours, 58 minutes, 28 seconds
        Last reboot reason             Router rebooted after a normal shutdown.

    To verify SPMB status, use the show chassis spmb command. Sample command output from a T4000 router is as follows:

    user@host> show chassis spmb
    Slot 0 information:
      State                          Online    
      Total CPU Utilization            18%
      Interrupt CPU Utilization         0%
      Memory Heap Utilization           0%
      Buffer Utilization               22%
      Start time:                    2012-02-09 22:51:09 PST
      Uptime:                        2 hours, 25 minutes, 45 seconds
    Slot 1 information:
      State                          Online - Standby
      Total CPU Utilization             0%
      Interrupt CPU Utilization         0%
      Memory Heap Utilization           0%
      Buffer Utilization               22%
      Start time:                    2012-02-09 22:51:10 PST
      Uptime:                        2 hours, 25 minutes, 44 seconds

    jnxBoxKernelMemoryUsedPercent

    The object identifier for jnxBoxKernelMemoryUsedPercent is {jnxBoxAnatomy 16}. This object represents the amount of the kernel memory used, expressed as a percentage of the total available memory. The object shows 0 if the kernel memory usage is unavailable or inapplicable. When the kernel memory usage exceeds 80 percent, a system log message is logged and an RMON rising threshold trap is generated if RMON health monitoring is enabled for the device.

    jnxBoxSystemDomainType

    The object identifier for jnxBoxSystemDomainType is {jnxBoxAnatomy 17}. This object indicates the domain type of the device, that is, whether it is a root system domain (RSD; represented by integer 2) or a protected system domain (PSD; represented by integer 3). This object returns an integer value of 1, denoting not applicable, if the system domain type feature is not supported on the device.