Locating Channelized DS3 Alarms and Errors

 

Checklist for Channelized DS3 Alarms and Errors

Purpose

To check the most common Channelized DS3 alarms and errors when investigating line problems on a Juniper Networks router.

Action

Table 1 provides links and commands for Channelized DS3 alarms and errors.

Table 1: Checklist for Channelized DS3 Alarms and Errors

Tasks

Command or Action

Display Alarms and Errors for Channelized DS3 Interfaces

show interfaces t1-fpc/pic/port:channel extensive

Display Alarms and Errors for Channelized DS3 Interfaces

Purpose

To display channelized DS3 alarms and errors, use the following Junos OS command-line interface (CLI) operational mode command:

Action

Sample Output 1

user@host> show interfaces t1-1/2/0:5 extensive

Sample Output 2

user@host> show interfaces t1-1/2/0:19 extensive

Meaning

The sample output shows the active alarms and active defects. Sample output 1 shows no active alarms or defects.

Sample output 2 shows that the physical and logical links are down, with active alarms and defects. When a major error (such as an alarm indication signal [AIS]) is seen for a few consecutive frames, a defect is declared within 1 second from detection. At the defect level, the interface is taken down and routing protocols are immediately notified (this is the default). In most cases, when a defect persists for 2.5 seconds plus or minus 0.5 seconds, an alarm is declared.

Notification messages are logged at the alarm level. Depending on the type of T1 alarm, you can configure the craft panel to display the red or yellow alarm LED and simultaneously have the alarm relay activate a physically connected device (such as a bell).

Table 2 shows T1 media-specific alarms or defects that can render the interface unable to pass packets.

Table 2: T1 Media Alarms and Error Definitions

T1 Media Alarm or Error

Definitions

AIS

Alarm indication signal (blue alarm)

BEE

Block error event

BES

Bursty errored seconds

BPV

Bipolar violation

CS

Controlled slip

ES

Errored seconds

EXZ

Excessive zeros

LCV

Line code violation

LES

Line errored seconds

LOF

Loss of frame

LOS

Loss of signal

PCV

Path code violation

SEF

Severely errored frame

SEFS

Severely errored frame seconds

SES

Severely errored seconds

UAS

Unavailable seconds

YLW

Yellow alarm