Purpose

Verify that the switch disables the downlink interface when it detects an uplink failure.

Action

  1. View the current uplink failure detection status:
    user@switch> show uplink-failure-detection
    Note

    The asterisk (*) indicates that the link is up.

  2. Disable the uplink interface:
    [edit]

    user@switch# set interface xe-0/0/0 disable
  3. Save the configuration on the switch.
  4. View the current uplink failure detection status:
    user@switch> show uplink-failure-detection

Meaning

The output in Step 1 shows that the uplink interface is up, and hence that the downlink interface is also up, and that the status of Failure Action is Inactive.