switch (IPLC)

 

Syntax

Hierarchy Level

Release Information

Statement introduced in Junos OS Releases 15.1F6 17.1R1.

Description

Switch the specified wavelength from the IPLC port to the specified local or remote optical interface.

The IPLC is designed to connect the ADD and DROP ports on the front panel to compatible optical PICs or MICs on the local or remote chassis. Wavelengths configured on the local IPLC ADD ports are multiplexed and sent over the Line OUT port of the IPLC base module. The remote IPLC base module receives the signal on the Line IN port and demultiplexes the wavelengths to the DROP ports on the front panel of the IPLC according to the configuration of the remote IPLC. After you have made the physical connections between the IPLC ports and the local and remote optical interfaces, you need to configure the IPLC to switch the wavelengths to the optical interfaces.

This statement requires you to make the following connections:

Note

The specified slot must contain an IPLC base module or IPLC expansion module.

Options

fpc-slotSpecify the IPLC slot number.
interface-nameSpecify the name of the optical interface to which you want to switch the specified wavelength. This field is free-form text.
nmSpecify the wavelength number you want to switch.
RemoteSpecify that the wavelength is to be switched to an optical interface on a remote chassis.

Example: Switching Wavelengths to an Optical Interface on the Local Chassis

To switch wavelength 1550.12 on the local IPLC module in slot 2 to the local et-1/1/0 interface, enter the following:

Example: Switching Wavelengths to an Optical Interface on the Remote Chassis

To switch wavelength 1550.12 on the local IPLC module in slot 2 to an optical interface on a remote chassis, enter the following:

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.