reject-timeout
Syntax
reject-timeout value;
Hierarchy Level
[edit security idp sensor-configuration
flow]
Release Information
Statement introduced in Junos OS Release 9.2.
Description
Specify the amount of time in seconds within which a response must be received.
This time-out is applied on flow when drop-connection action is taken by IPS for TCP flow.
Options
value—Maximum amount of time in seconds.
Range: 1 through 65,535 seconds
Default: 300 seconds
Required Privilege Level
security—To view this statement in the configuration.
security-control—To add this statement to the configuration.