    request chassis power-manager reset ambient-config

    Syntax

    request chassis power-manager reset ambient-config

    Hierarchy Level

    edit

    Release Information

    Statement introduced in Junos OS Release 15.1

    Description

    Clear the overshooting condition and reset the power of the overshooting FPC according to the configured ambient temperature. The overshooting condition occurs when an FPC consumes more than the allocated power for more than three minutes. When this condition occurs, the power allocation does not automatically reverse even if the FPC power consumption has reduced to its earlier, lower level.

    Required Privilege Level

    interface—To view this statement in the configuration.

    interface-control—To add this statement to the configuration