Description

Configure the interval (in seconds) that the device waits between port statistics update messages. Polling refers to the device gathering various statistics for the network interfaces configured for sFlow monitoring and exporting the statistics to the configured sFlow collector.

Default

If no polling interval is configured for a particular interface, the device waits the number of seconds that is configured as the polling interval in the global sFlow configuration. If no polling interval is specified in the global configuration, the device waits 20 seconds between messages.

Options

seconds—Number of seconds between port statistics update messages. A value of 0 (zero) specifies that polling is disabled.

Range: 0 through 3600 seconds

Default: 20 seconds

Required Privilege Level

routing—To view this statement in the configuration.

routing-control—To add this statement to the configuration.