    manual (Master Clock)

    Syntax

    manual;

    Hierarchy Level

    [edit protocols ptp master interface interface-name unicast-mode clock-client ip-address local-ip-address local-ip-address]

    Release Information

    Statement introduced in Junos OS Release 12.3 for ACX Series Routers.

    Description

    Configure this remote clock client when it does not use unicast negotiation to join the boundary master. When this statement is configured, the boundary master starts sending announce and synchronization messages to the remote client.

    Note: The number of manual clients you can configure varies depending on the number of secure clients configured. You can configure any combination of manual and secure clients as long as the combined total amounts to 256.

    Required Privilege Level

    routing—To view this statement in the configuration.

    routing-control—To add this statement to the configuration.