loop-timing

 

Syntax

Hierarchy Level

Release Information

Statement introduced before Junos OS Release 7.4.

Description

For channelized IQ interfaces and non-IQ channelized STM1 interfaces only, configure the SONET/SDH or DS3-level clocking source.

Note

On M Series, MX Series, and T Series routers, under E1 channels, loop timing can be configured only at channel 0. When you configure on channel 0, it is applicable on all channels as internal by default.

Options

loop-timing—Configure loop timing (external) clocking.

no-loop-timing—Configure line timing (internal) clocking.

Default: no-loop-timing

Required Privilege Level

interface—To view this statement in the configuration.