join-timer (MVRP)
Syntax
Hierarchy Level
Release Information
Statement introduced in Junos OS Release 10.0.
Description
Configure the maximum number of milliseconds interfaces must wait before sending Multiple VLAN Registration Protocol (MVRP) protocol data units (PDUs).
Maintain default timer settings unless there is a compelling reason to change the settings. Modifying timers to inappropriate values might cause an imbalance in the operation of MVRP.
Default
200 milliseconds
Options
milliseconds—Interval that the interface must wait before sending MVRP PDUs (range from 100 milliseconds through 500 milliseconds). Maintain default timer settings unless there is a compelling reason to change the settings. Modifying timers to inappropriate values might cause an imbalance in the operation of MVRP.
Required Privilege Level
routing—To view this statement in the
configuration.
routing-control—To add this statement
to the configuration.