hold-time (LDP Synchronization for IS-IS)

 

Syntax

Hierarchy Level

Release Information

Statement introduced in Junos OS Release 7.5.

Description

Configure the time period to advertise the maximum cost metric for a link that is not fully operational.

Note

When an interface has been in the holddown state for more than 3 minutes, a system log message with a warning level is sent. This message appears in both the messages file and the trace file.

Options

seconds—Hold-time value, in seconds.

Range: 1 through 65,535 seconds

Default: Infinity

Required Privilege Level

routing—To view this statement in the configuration.