show uplink-failure-detection
Syntax
Release Information
Command introduced in Junos OS Release 11.1.
Description
Display information about the uplink-failure-detection group, the member interfaces, and their status.
Options
Required Privilege Level
view
Related Documentation
List of Sample Output
show uplink-failure-detectionshow uplink-failure-detection group g2
Output Fields
Table 1 lists the output fields for the show uplink-failure-detection command. Output fields are listed in the approximate order in which they appear.
Table 1: show uplink-failure-detection Output Fields
Field Name | Field Description |
---|---|
Group | Name of the group. |
Uplink | The uplink interface or interfaces configured as link-to-monitor. Note: The asterisk (*) indicates that the link is up. |
Downlink | The downlink interface or interfaces configured as link-to-disable. Note: The asterisk (*) indicates that the link is up. |
Failure Action | Status of uplink failure detection:
|
Debounce Interval | The amount of time, in seconds, that elapses before the downlink interfaces are brought up after a state change of the uplink interfaces. |
Sample Output
show uplink-failure-detection
user@switch> show uplink-failure-detection
Group : group1 Uplink : ge-0/0/0* Downlink : ge-0/0/1* Failure Action : Inactive Group : group2 Uplink : ge-0/0/3.0 Downlink : ge-0/0/4.0 Failure Action : Active Debounce Interval : 20
Sample Output
show uplink-failure-detection group g2
user@switch> show uplink-failure-detection group
g2