Help us improve your experience.

Let us know what you think.

Do you have time for a two-minute survey?

 

show chassis hardware

 

List of Syntax

Syntax

Syntax (EX Series, MX104, MX204, MX2010, MX2020, MX10003, MX10008, and MX2008 Universal Routing Platforms)

Syntax (TX Matrix Router)

Syntax (TX Matrix Plus Router)

Syntax (MX Series Routers)

Syntax (QFX Series)

Syntax

Syntax (EX Series, MX104, MX204, MX2010, MX2020, MX10003, MX10008, and MX2008 Universal Routing Platforms)

Syntax (TX Matrix Router)

Syntax (TX Matrix Plus Router)

Syntax (MX Series Routers)

Syntax (QFX Series)

Release Information

Command introduced before Junos OS Release 7.4.

models option introduced in Junos OS Release 8.2.

Command introduced in Junos OS Release 9.0 for EX Series switches.

sfc option introduced in Junos OS Release 9.6 for the TX Matrix Plus router.

Command introduced in Junos OS Release 11.1 for QFX Series.

Command introduced in Junos OS Release 12.1X48 for PTX Series Packet Transport Routers.

Command introduced in Junos OS Release 12.2 for ACX Series Universal Metro Routers.

Command introduced in Junos OS Release 12.3 for MX2010 and MX2020 Universal Routing Platforms.

Information for disk and usb introduced in Junos OS Release 15.1X53-D60 for QFX10002, QFX10008, and QFX10016 switches.

Command introduced in Junos OS Release 15.1X54-D20 for ACX5048 and ACX5096 Routers.

Command introduced in Junos OS Release 17.2 for MX2008 Universal Routing Platforms and PTX10008 Routers.

Command introduced in Junos OS Release 17.3 for MX10003 Universal Routing Platforms and MX150 Router Appliance.

Command introduced in Junos OS Release 17.4 for MX204 Routers.

Command introduced in Junos OS Release 18.1R1 for EX9251 Switches.

Command introduced in Junos OS Release 18.2R1 for MX10008 Routers and EX9253 Switches.

Note

Routers and routing platforms use the basic syntax, unless otherwise listed. For example, the EX Series has an additional satellite parameter available.

Description

Display a list of all Flexible PIC Concentrators (FPCs) and PICs installed in the router or switch chassis, including the hardware version level and serial number.

In the EX Series switch command output, FPC refers to the following:

  • On EX2200 switches, EX3200 switches, EX4200 standalone switches, and EX4500 switches—Refers to the switch; FPC number is always 0.

  • On EX4200 switches in a Virtual Chassis configuration—Refers to the member of a Virtual Chassis; FPC number equals the member ID, from 0 through 9.

  • On EX8208 and EX8216 switches—Refers to a line card; FPC number equals the slot number for the line card.

On QFX3500, QFX5100, and OCX Series standalone switches, and PTX1000 routers both the FPC and FPC number are always 0.

On T4000 Type 5 FPCs, there are no top temperature sensor or bottom temperature sensor parameters. Instead, fan intake temperature sensor and fan exhaust temperature sensors parameters are displayed.

Starting from Junos OS Release 11.4, the output of the show chassis hardware models operational mode command displays the enhanced midplanes FRU model numbers (CHAS-BP3-MX240-S, CHAS-BP3-MX480-S or CHAS-BP3-MX960-S) based on the router. Prior to release 11.4, the FRU model numbers are left blank when the router has enhanced midplanes. Note that the enhanced midplanes are introduced through the Junos OS Release 13.3, but can be supported on all Junos OS releases.

Starting with Junos OS Release 14.1, the output of the show chassis hardware detail | extensive | clei-models | models operational mode command displays the new DC power supply module (PSM) and power distribution unit (PDU) that are added to provide power to the high-density FPC (FPC2-PTX-P1A) and other components in a PTX5000 Packet Transport Router.

Options

noneDisplay information about hardware. For a TX Matrix router, display information about the TX Matrix router and its attached T640 routers. For a TX Matrix Plus router, display information about the TX Matrix Plus router and its attached routers.
clei-models(Optional) Display Common Language Equipment Identifier (CLEI) barcode and model number for orderable field-replaceable units (FRUs).
detail(Optional) Include RAM and disk information in output.
extensive(Optional) Display ID EEPROM information.
all-members(MX Series routers only) (Optional) Display hardware-specific information for all the members of the Virtual Chassis configuration.
interconnect-device name(QFabric systems only) (Optional) Display hardware-specific information for the Interconnect device.
lcc number(TX Matrix routers and TX Matrix Plus router only) (Optional) On a TX Matrix router, display hardware information for a specified T640 router (line-card chassis) that is connected to the TX Matrix router. On a TX Matrix Plus router, display hardware information for a specified router (line-card chassis) that is connected to the TX Matrix Plus router.

Replace number with the following values depending on the LCC configuration:

  • 0 through 3, when T640 routers are connected to a TX Matrix router in a routing matrix.

  • 0 through 3, when T1600 routers are connected to a TX Matrix Plus router in a routing matrix.

  • 0 through 7, when T1600 routers are connected to a TX Matrix Plus router with 3D SIBs in a routing matrix.

  • 0, 2, 4, or 6, when T4000 routers are connected to a TX Matrix Plus router with 3D SIBs in a routing matrix.

local(MX Series routers only) (Optional) Display hardware-specific information for the local Virtual Chassis members.
member member-id(MX Series routers and EX Series switches) (Optional) Display hardware-specific information for the specified member of the Virtual Chassis configuration. Replace member-id variable with a value 0 or 1.
models(Optional) Display model numbers and part numbers for orderable FRUs and, for components that use ID EEPROM format v2, the CLEI code.
node-device name(QFabric systems only) (Optional) Display hardware-specific information for the Node device.
satellite [slot-id slot-id | device-alias alias-name](Junos Fusion only) (Optional) Display hardware information for the specified satellite device in a Junos Fusion, or for all satellite devices in the Junos Fusion if no satellite devices are specified.
scc(TX Matrix router only) (Optional) Display hardware information for the TX Matrix router (switch-card chassis).
sfc number(TX Matrix Plus router only) (Optional) Display hardware information for the TX Matrix Plus router (switch-fabric chassis). Replace number variable with 0.

Additional Information

The show chassis hardware detail command now displays DIMM information for the following Routing Engines, as shown in Table 1.

Table 1: Routing Engines Displaying DIMM Information

Routing EnginesRouters

RE-S-1800x2 and RE-S-1800x4

MX240, MX480, and MX960 routers

RE-A-1800x2

M120 and M320 routers

In Junos OS Release 11.4 and later, the output for the show chassis hardware models operational mode command for MX Series routers display the enhanced midplanes FRU model numbers—CHAS-BP3-MX240-S, CHAS-BP3-MX480-S, or CHAS-BP3-MX960-S—based on the router. In releases before Junos OS Release 11.4, the FRU model numbers are left blank when the router has enhanced midplanes. Note that the enhanced midplanes are introduced through Junos OS Release 13.3, but can be supported on all Junos OS releases.

Starting with Junos OS Release 17.3R1, the output of the show chassis hardware command displays the mode in which vMX is running (performance mode or lite mode) in the part number field for the FPC. RIOT-PERF indicates performance mode and RIOT-LITE indicates lite mode.

Required Privilege Level

view

Related Documentation

List of Sample Output

show chassis hardware (MX10008 Router)

show chassis hardware clei-models (PTX10016 Routers)

show chassis hardware detail (EX9251 Switch)

show chassis hardware extensive (T640 Router)

show chassis hardware interconnect-device (QFabric Systems)

show chassis hardware lcc (TX Matrix Router)

show chassis hardware models (MX2010 Router)

show chassis hardware node-device (QFabric Systems)

show chassis hardware scc (TX Matrix Router)

show chassis hardware sfc (TX Matrix Plus Router)

Output Fields

Table 2 lists the output fields for the show chassis hardware command. Output fields are listed in the approximate order in which they appear.

Table 2: show chassis hardware Output Fields

Field Name

Field Description

Level of Output

Item

Chassis component:

  • (EX Series switches)—Information about the chassis, Routing Engine (SRE and Routing Engine modules in EX8200 switches), power supplies, fan trays, and LCD panel. Also displays information about Flexible PIC Concentrators (FPCs) and associated Physical Interface Cards (PICs). Information about the backplane, midplane, and SIBs (SF modules) is displayed for EX8200 switches.

  • (MX Series routers and EX Series switches)—Information about the backplane, Routing Engine, Power Entry Modules (PEMs), and fan trays. Also displays information about Flexible PIC Concentrators (FPCs) and associated Physical Interface Cards (PICs), Modular Port Concentrators (MPCs) and associated Modular Interface Cards (MICs), or Dense Port Concentrators (DPCs). MX80 routers have a single Routing Engine and a built-in Packet Forwarding Engine that attaches directly to MICs. The Packet Forwarding Engine has two “pseudo” FPCs (FPC 0 and FPC1). MX80 routers also have a Forwarding Engine Board (FEB). MX104 routers have a built-in Packet forwarding Engine and a Forwarding Engine Board (FEB). The Packet Forwarding Engine of the MX104 router has three “pseudo” FPCs (FPC0, FPC1, and FPC2).

  • (M Series routers, except for the M320 router)—Information about the backplane; power supplies; fan trays; Routing Engine; maxicab (the connection between the Routing Engine and the backplane, for the M40 router only); SCB, SSB, SFM, or FEB; MCS and PCG (for the M160 router only); each FPC and PIC; and each fan, blower, and impeller.

  • (M120, M320, and T Series routers)—Information about the backplane, power supplies, fan trays, midplane, FPM (craft interface), CIP, PEM, SCG, CB, FPC, PIC, SFP, SPMB, and SIB.

  • (QFX Series)—Information about the chassis, Pseudo CB, Routing Engine, power supplies, fan trays, Interconnect devices, and Node devices. Also displays information about Flexible PIC Concentrators (FPCs) and associated Physical Interface Cards (PICs).

  • (PTX Series)—Information about the chassis, midplane, craft interface (FPM), power distribution units (PDUs) and Power Supply Modules (PSMs), Centralized Clock Generators (CCGs), Routing Engines, Control Boards (CBs) and Switch Processor Mezzanine Boards (SPMBs), Flexible PIC Concentrators (FPCs), PICs, Switch Interface Boards (SIBs), and fan trays (vertical and horizontal).

  • (MX2010, MX2020, and MX2008 routers)—Information about the chassis, midplane, craft interface (FPM), power midplane (PMP), Power Supply Modules (PSMs), Power Distribution Modules (PDMs), Routing Engines, Control Boards (CBs) and Switch Processor Mezzanine Boards (SPMBs), Switch Fabric Boards (SFBs), Flexible PIC Concentrators (FPCs), PICs, adapter cards (ADCs) and fan trays.

  • (vMX routers)—Information about the chassis, midplane, Routing Engines, and Control Boards (CBs). Also displays information about Flexible PIC Concentrators (FPCs) and associated Modular Interface Cards (MICs) and Physical Interface Cards (PICs).

All levels

Version

Revision level of the chassis component.

All levels

Part number

Part number of the chassis component.

All levels

Serial number

Serial number of the chassis component. The serial number of the backplane is also the serial number of the router chassis. Use this serial number when you need to contact Juniper Networks Customer Support about the router or switch chassis.

All levels

Assb ID or Assembly ID

(extensive keyword only) Identification number that describes the FRU hardware.

extensive

Assembly Version

(extensive keyword only) Version number of the FRU hardware.

extensive

Assembly Flags

(extensive keyword only) Flags.

extensive

FRU model number

(clei-models, extensive, and models keyword only) Model number of the FRU hardware component.

none specified

CLEI code

(clei-models and extensive keyword only) Common Language Equipment Identifier code. This value is displayed only for hardware components that use ID EEPROM format v2. This value is not displayed for components that use ID EEPROM format v1.

none specified

EEPROM Version

ID EEPROM version used by the hardware component: 0x00 (version 0), 0x01 (version 1), or 0x02 (version 2).

extensive

Description

Brief description of the hardware item:

  • Type of power supply.

  • Type of PIC. If the PIC type is not supported on the current software release, the output states Hardware Not Supported.

  • Type of FPC: FPC Type 1, FPC Type 2, FPC Type 3, FPC Type 4 , or FPC TypeOC192.

    On EX Series switches, a brief description of the FPC.

    The following list shows the PIM abbreviation in the output and the corresponding PIM name.

    • 2x FE—Either two built-in Fast Ethernet interfaces (fixed PIM) or dual-port Fast Ethernet PIM

    • 4x FE—4-port Fast Ethernet ePIM

    • 1x GE Copper—Copper Gigabit Ethernet ePIM (one 10-Mbps, 100-Mbps, or 1000-Mbps port)

    • 1x GE SFP—SFP Gigabit Ethernet ePIM (one fiber port)

    • 2x Serial—Dual-port serial PIM

    • 2x T1—Dual-port T1 PIM

    • 2x E1—Dual-port E1 PIM

    • 2x CT1E1—Dual-port channelized T1/E1 PIM

    • 1x T3—T3 PIM (one port)

    • 1x E3—E3 PIM (one port)

    • 4x BRI S/T—4-port ISDN BRI S/T PIM

    • 4x BRI U—4-port ISDN BRI U PIM

    • 1x ADSL Annex A—ADSL 2/2+ Annex A PIM (one port, for POTS)

    • 1x ADSL Annex B—ADSL 2/2+ Annex B PIM (one port, for ISDN)

    • 2x SHDSL (ATM)—G SHDSL PIM (2-port two-wire module or 1-port four-wire module)

    • 1x TGM550—TGM550 Telephony Gateway Module (Avaya VoIP gateway module with one console port, two analog LINE ports, and two analog TRUNK ports)

    • 1x DS1 TIM510—TIM510 E1/T1 Telephony Interface Module (Avaya VoIP media module with one E1 or T1 trunk termination port and ISDN PRI backup)

    • 4x FXS, 4xFX0, TIM514—TIM514 Analog Telephony Interface Module (Avaya VoIP media module with four analog LINE ports and four analog TRUNK ports)

    • 4x BRI TIM521—TIM521 BRI Telephony Interface Module (Avaya VoIP media module with four ISDN BRI ports)

    • Crypto Accelerator Module—For enhanced performance of cryptographic algorithms used in IP Security (IPsec) services

  • MPC M 16x 10GE—16-port 10-Gigabit Module Port Concentrator that supports SFP+ optical transceivers. (Not on EX Series switches.)

  • For hosts, the Routing Engine type.

  • For small form-factor pluggable transceiver (SFP) modules, the type of fiber: LX, SX, LH, or T.

  • LCD description for EX Series switches (except EX2200 switches).

  • MPC2—1-port MPC2 that supports two separate slots for MICs.

  • MPC3E—1-port MPC3E that supports two separate slots for MICs (MIC-3D-1X100GE-CFP and MIC-3D-20GE-SFP) on MX960, MX480, and MX240 routers. The MPC3E maps one MIC to one PIC (1 MIC, 1 PIC), which differs from the mapping of legacy MPCs.

  • 100GBASE-LR4, pluggable CFP optics

  • Supports the Enhanced MX Switch Control Board with fabric redundancy and existing SCBs without fabric redundancy.

  • Interoperates with existing MX Series line cards, including Flexible Port Concentrators (FPC), Dense Port Concentrators (DPCs), and Modular Port Concentrators (MPCs).

  • MPC4E—Fixed configuration MPC4E that is available in two flavors: MPC4E-3D-32XGE-SFPP and MPC4E-3D-2CGE-8XGE on MX2020, MX960, MX480, and MX240 routers.

  • LCD description for MX Series routers

All levels

Sample Output

show chassis hardware (MX10008 Router)

user@host> show chassis hardware

show chassis hardware clei-models (PTX10016 Routers)

user@host> show chassis hardware clei-models

show chassis hardware detail (EX9251 Switch)

user@switch> show chassis hardware

show chassis hardware extensive (T640 Router)

user@host> show chassis hardware extensive

show chassis hardware interconnect-device (QFabric Systems)

user@switch> show chassis hardware interconnect-device interconnect1

show chassis hardware lcc (TX Matrix Router)

user@host> show chassis hardware lcc 0

show chassis hardware models (MX2010 Router)

user@host > show chassis hardware models

show chassis hardware node-device (QFabric Systems)

user@switch> show chassis hardware node-device node1

show chassis hardware scc (TX Matrix Router)

user@host> show chassis hardware scc

show chassis hardware sfc (TX Matrix Plus Router)

user@host> show chassis hardware sfc 0