show chassis environment service-node
Syntax
Release Information
Command introduced in Junos OS Release 13.3 for PTX5000 routers with CSE2000.
Command introduced in Junos OS Release 13.3R4 for PTX3000 routers with CSE2000.
Command introduced in Junos OS Release 17.2 for PTX10008 Routers.
Description
Display environmental information about the CSE2000 service cards.
Options
Required Privilege Level
view
Related Documentation
List of Sample Output
show chassis environment service-node slot 1show chassis environment service-node
Output Fields
Table 1 lists the output fields for the show chassis environment service-node command. Output fields are listed in the approximate order in which they appear.
Table 1: show chassis environment service-node Output Fields
Field Name | Field Description |
---|---|
State | State of the service card:
|
D_SAS2308_TEMP_D Temperature | Temperature of sensors near the Serial Attached SCSI (SAS) controller for the bottom service card. The temperature threshold values:
|
D_PCH_TEMP_DET Temperature | Temperature of sensors near the Platform Controller Hub for the bottom service card. The temperature threshold values:
|
D_DDR3_TEMP_DET Temperature | Temperature of sensors near the DDR3 memory for the bottom service card. The temperature threshold values:
|
D_CPU0_TEMP_DET Temperature | Temperature of the CPU0 for the bottom service card. The temperature threshold values:
|
D_CPU1_TEMP_DET Temperature | Temperature of the CPU1 for the bottom service card. The temperature threshold values:
|
U_SAS2308_TEMP_D Temperature | Temperature of sensors near the Serial Attached SCSI (SAS) controller for the upper service card. The temperature threshold values:
|
U_PCH_TEMP_DET Temperature | Temperature of sensors near the Platform Controller Hub for the upper service card. The temperature threshold values:
|
U_DDR3_TEMP_DET Temperature | Temperature of sensors near the DDR3 memory for the upper service card. The temperature threshold values:
|
U_CPU0_TEMP_DET Temperature | Temperature of the CPU0 for the upper service card. The temperature threshold values:
|
U_CPU1_TEMP_DET Temperature | Temperature of the CPU1 for the upper service card. The temperature threshold values:
|
Power | The left column displays the label assigned to the voltage sensor. The right column displays the current reading from the voltage sensor. List of voltage sensors: Note: The prefix D indicates the voltage sensor for the bottom service card and the prefix U indicates the voltage sensor for the upper service card.
|
Item | Fan item identifier. |
Status | Status of the fan:
|
RPM | Fan speed in revolutions per minute (RPM). |
Measurement | Fan speed status based on different chassis cooling requirements:
|
Sample Output
show chassis environment service-node slot 1
user@host> show chassis environment service-node
slot 1
ESC 1 status: State Online D_SAS2308_TEMP_D Temperature38 degrees C / 100 degrees F D_PCH_TEMP_DET Temperature 38 degrees C / 100 degrees F D_DDR3_TEMP_DET Temperature36 degrees C / 96 degrees F D_CPU0_TEMP_DET Temperature51 degrees C / 123 degrees F D_CPU1_TEMP_DET Temperature54 degrees C / 129 degrees F Power D_P1V5_VDDQ_CPU0 1470 mV D_P1V5_VDDQ_CPU1 1480 mV D_PVTT_CPU0 1040 mV D_PVTT_CPU1 1050 mV D_PVCCP_CPU0 860 mV D_PVCCP_CPU1 880 mV D_P3V3 3360 mV D_P5V 5040 mV D_P12V 12100 mV D_PSU1_5VSB 5000 mV D_PSU1_+12V 12000 mV D_PSU2_5VSB 5000 mV D_PSU2_+12V 12000 mV Item Status RPM Measurement D_FAN1 OK 22800 Spinning at high speed D_FAN2 Failed 0 Failure D_FAN3 OK 23600 Spinning at high speed D_FAN4 OK 23200 Spinning at high speed D_FAN5 OK 23200 Spinning at high speed D_FAN6 OK 23600 Spinning at high speed
Sample Output
show chassis environment service-node
user@host> show chassis environment service-node
ESC 0 status: State Online U_SAS2308_TEMP_D Temperature40 degrees C / 104 degrees F U_PCH_TEMP_DET Temperature 40 degrees C / 104 degrees F U_DDR3_TEMP_DET Temperature39 degrees C / 102 degrees F U_CPU0_TEMP_DET Temperature64 degrees C / 147 degrees F U_CPU1_TEMP_DET Temperature55 degrees C / 131 degrees F Power U_P1V5_VDDQ_CPU0 1480 mV U_P1V5_VDDQ_CPU1 1480 mV U_PVTT_CPU0 1040 mV U_PVTT_CPU1 1050 mV U_PVCCP_CPU0 880 mV U_PVCCP_CPU1 870 mV U_P3V3 3360 mV U_P5V 5040 mV U_P12V 12000 mV Item Status RPM Measurement U_FAN1 OK 18200 Spinning at high speed U_FAN2 OK 18700 Spinning at high speed U_FAN3 OK 18200 Spinning at high speed U_FAN4 OK 19000 Spinning at high speed U_FAN5 OK 19200 Spinning at high speed U_FAN6 OK 18400 Spinning at high speed ESC 1 status: State Online D_SAS2308_TEMP_D Temperature40 degrees C / 104 degrees F D_PCH_TEMP_DET Temperature 39 degrees C / 102 degrees F D_DDR3_TEMP_DET Temperature38 degrees C / 100 degrees F D_CPU0_TEMP_DET Temperature61 degrees C / 141 degrees F D_CPU1_TEMP_DET Temperature54 degrees C / 129 degrees F Power D_P1V5_VDDQ_CPU0 1470 mV D_P1V5_VDDQ_CPU1 1480 mV D_PVTT_CPU0 1040 mV D_PVTT_CPU1 1050 mV D_PVCCP_CPU0 850 mV D_PVCCP_CPU1 880 mV D_P3V3 3360 mV D_P5V 5040 mV D_P12V 12100 mV D_PSU1_5VSB 5000 mV D_PSU1_+12V 12000 mV D_PSU2_5VSB 5000 mV D_PSU2_+12V 12000 mV Item Status RPM Measurement D_FAN1 OK 18400 Spinning at high speed D_FAN2 OK 19200 Spinning at high speed D_FAN3 OK 18200 Spinning at high speed D_FAN4 OK 19200 Spinning at high speed D_FAN5 OK 18700 Spinning at high speed D_FAN6 OK 18700 Spinning at high speed